Product Highlights

  • High Precision Accuracy: Offers accuracy classes of 0.2%, 0.5%, and 1% for reliable measurements.
  • Wide Measurement Range: Supports primary currents from 500A to 3000A with max continuous input of 3600A.
  • Large Jaw Opening: Features a 125mm jaw opening designed for easy installation on thick cables.
  • Low Phase Shift: Ensures accurate power measurement with excellent transformation and low phase shift.
  • Safety Certified: Conforms to EN 61010 standards with 600V CAT III overvoltage category protection.
  • Customizable Ratios: Provides customized transformation ratios such as 1000:1 or 2000:1 based on needs.
  • Versatile Output Options: Supports AC current outputs (500mA-5A) and AC voltage outputs (333mV-5V).
  • Durable Construction: Made from PC+ABS+Polycarbonate with UL94 V0 flame retardant material.

Product Images of Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer

Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer pictures & photos
Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer pictures & photos
Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer pictures & photos
Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer pictures & photos
Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer pictures & photos
Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer pictures & photos
Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
  • Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
  • Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
    Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
  • Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
    Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
  • Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
    Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
  • Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
    Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
  • Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
    Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
  • Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
    Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer

Find Similar Products

Product Description

Q125B CABLE 125MM 3000A SPLIT CORE SQUARE BUS BAR AC CLAMP ON CURRENT TRANSFORMER

Cable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current TransformerCable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current TransformerCable 125mm 3000A Split Core Square Bus Bar AC Clamp on Current Transformer
The Q125B is a high performance AC clamp on Current transformer with excellent transformation and low phase shift. The high quality magnetic core and uniform windings provide for accurate measurements up to 1000A AC/2000A AC/3000A AC. The Round jaw permits 125mm cable positioning. Provide excellent TRMS capabilities and reliable signal reproduction.

APPLICATIONS

  • Large industrial loads
  • Measuring around cable bundles
  • Power load monitoring
  • Electrical utility
  • HVAC
  • Industrial maintenance
  • Laboratory
  • Plant maintenance
  • Cable fault tester

FEATURES

  • Measurement range of 1A to 3600A AC
  • Large jaw opening designed
  • Improved ergonomic design and easy operation
  • Conforms to EN 61010, 600V CAT III
  • Low phase shift for power measurement
  • Nominal range: 1 to 1000AAC, 1 to 2000AAC, 1 to 3000AAC
  • Transformation ratio: 1000:5, 2000:5, 3000:5
  • Output:5mA AC/A AC, 2.5mA AC/A AC, 1.666mA AC/A AC
  • Designed for use on DMMs, power and harmonic meters, recorders or instruments with AC current ranges
  • UL, CE mark
PARAMETERS
Electrical parameters
Ratio 1000: 1 or 2000:1 (customized)
Accuracy class 0.2%, 0.5%, 1%
Primary current 0 - 3000A AC
Secondary current 0 - 5A AC (customized)
Max. Cont. Input current 3600A
Over voltage category CAT III 600V
Output signal (AC current) 500mA,1A,2A,5A  AC at nominal input current
Electrical parameters - continued  
Output signal (AC voltage) 333mV, 500mV, 1V, 5V AC at nominal input current
Frequency range 40Hz-2000Hz
Dielectric strength 3KV 50Hz/60Hz  at 1 minute
Temperature range -20°C to +55°C
Output 2.5 meter cable with D01 connector
Max. voltage not insulated conductors 600 V
Standard EN 61010-1, EN 61010-2-032, IEC60044-1 
Installation clamp type
Output mode lead output(2.5m)
Mechanical parameters
Dimensions (L x W x H) (mm) 180 x 319 x 35
Weight (g) 1100
Holding wire diameter (mm) φ125
Max. jaw opening (mm) 125
Color Black
Material PC+ABS+Polycarbonate, UL94 V0
Electrical parameters
Ratio 1000: 1 or 2000:1 (customized)
Accuracy class 0.2%, 0.5%, 1%
Primary current 0 - 3000A AC
Secondary current 0 - 5A AC (customized)
Max. Cont. Input current 3600A
Over voltage category CAT III 600V
Output signal (AC current) 500mA,1A,2A,5A  AC at nominal input current
Electrical parameters - continued  
Output signal (AC voltage) 333mV, 500mV, 1V, 5V AC at nominal input current
Frequency range 40Hz-2000Hz
Dielectric strength 3KV 50Hz/60Hz  at 1 minute
Temperature range -20°C to +55°C
Output 2.5 meter cable with D01 connector
Max. voltage not insulated conductors 600 V
Standard EN 61010-1, EN 61010-2-032, IEC60044-1 
Installation clamp type
Output mode lead output(2.5m)
Mechanical parameters
Dimensions (L x W x H) (mm) 180 x 319 x 35
Weight (g) 1100
Holding wire diameter (mm) φ125
Max. jaw opening (mm) 125
Color Black
Material PC+ABS+Polycarbonate, UL94 V0
Model  Rate Current Max Current Secondary Current Coil Ratio Burden Resistance Accuracy
Q125B-500 500A 600A 5A 100:1 2.5VA 0.5%
Q125B-600 600A 720A 5A 120:1 2.5VA 0.5%
Q125B-800 800A 960A 5A 160:1 2.5VA 0.5%
Q125B-1000 1000A 1200A 5A 200:1 2.5VA 0.5%
Q125B-1200 1200A 1440A 5A 240:1 2.5VA 0.5%
Q125B-1500 1500A 1800A 5A 300:1 2.5VA 0.5%
Q125B-2000 2000A 2400A 5A 400:1 2.5VA 0.5%
Q125B-3000 3000A 3600A 5A 600:1 2.5VA 0.5%
Q125B-500 500A 600A 1A 500:1 customized 0.5%
Q125B-600 600A 720A 1A 600:1 customized 0.5%
Q125B-800 800A 960A 1A 800:1 customized 0.5%
Q125B-1000 1000A 1200A 1A 1000:1 customized 0.2%
Q125B-1200 1200A 1440A 1A 1200:1 customized 0.2%
Q125B-1500 1500A 1800A 1A 1500:1 customized 0.2%
Q125B-2000 2000A 2400A 1A 2000:1 customized 0.2%
Q125B-3000 3000A 3600A 1A 3000:1 customized 0.2%

http://guangfuhui.en.made-in-china.com

About the Supplier

Watch Video
Watch Video
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.

About Our Factory & Business Background

Address
Bldg. 2-1111, Joy Mansion, No. 99 Chaoyang North Road, Chaoyang District, Beijing, China
Terms of Payment
LC, T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, CIF, FCA, EXW
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
TIANJING

Our Production Capability & Technical Expertise

Main Products
Current Transformer, Energy Meter Calibration, Power Quality Analyzer, Test Equipment, CT PT Analyzer, Relay Test Equipment, Split Core Current Transformer, Current Probe, Voltage Transformer, Power Meter

Our Industry Experience & Global Business Record

Export Year
2010-08-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the maximum jaw opening size?
The maximum jaw opening is 125mm, allowing it to fit around cables up to this diameter.
What accuracy classes are available?
The transformer is available in accuracy classes of 0.2%, 0.5%, and 1%.
Is the transformation ratio customizable?
Yes, customized transformation ratios such as 1000:1 or 2000:1 are available.
What safety standards does it comply with?
It conforms to EN 61010-1, EN 61010-2-032, and IEC60044-1 standards with 600V CAT III protection.
What are the output signal options?
Output signals include AC current (500mA, 1A, 2A, 5A) and AC voltage (333mV, 500mV, 1V, 5V).
What is the maximum continuous input current?
The maximum continuous input current is 3600A.
What material is used for the casing?
The casing is made of PC+ABS+Polycarbonate with a UL94 V0 flame retardant rating.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Product Groups

Product Catalogs