GF101 120A Single Phase Phantom Load Test Set Program-Controlled Single-Phase Standard Power Source
Product Description
Application of Single Phase Phantom Load Test Set Program-Controlled Single-Phase Standard Power Source
It is suitable for power department, measuring department, quality control department, research units, and institutions of higher learning, and electric energy meter, power distribution terminals, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and power source.
Main Functions and Features
To set up and take the load regulation of voltage, current, phase and frequency of the power factor;
To be set to 2 ~ 128 times of the amplitude and phase harmonics, and it can be added to the base wave in every harmonic output;
Voltage, current output a wide range, big power, high stability, waveform distortion degree is very small;
To have strong with load ability, and take capacitive, sensibility, resistance of composite type load or load and load regulation is higher than 0.01%;
To apply the 32 bit MPU + DSP + FPGA, powerful flexible;
To use hardware PID, fast response, the change of load will not cause output volatility;
Industrial frequency waves as high as 50000 points a week of the wave kneading, signal output without filter, precise output waveform, the harmonic output precision, harmonic distortion degree is small;
Range switching automatically;
To use software calibration, simple operation, stable and reliable;
To have the big screen, 320 X 240 LCD display, Chinese or English interface, operating simplely;
To have perfect over-current, over-voltage, heat, a shorts-and-opens, overload protection, automatic failure detection;
With RS232 interface, and PC connection;
To take place machine software, it can be output through the PC software of program.
Product Parameters
AC voltage output
Range: 57.7V / 100V / 220V / 380V / 750V, range switch automatically
Adjust fineness: 0.01% RG
Accuracy: RG is higher than 0.05%
Stability: Better than 0.01% RG / 1 min
Distortion degree: Better than 0.1% (not capacitive load)
Output power: The rated each phase is 40 VA
Full load regulation rate: Less than 0.01% RG
Full load regulation time: Less than 1mS
Temperature drift: 8 PPM /
Long-term stability: 60 PPM/year
AC current output
Range: 0.1/ 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 100A, range switch automatically
Adjust fineness: 0.01% RG
Accuracy: RG is higher than 0.05%
Stability: Better than 0.01% RG / 1 min
Distortion degree: Better than 0.1% (not capacitive load)
Output power: The rated each phase is 40 VA
Full load regulation rate: Less than 0.01% RG
Full load regulation time: Less than 1mS
Temperature drift: 8 PPM /
Long-term stability: 60 PPM/year
Phase angle
Adjusting range: 0 ~ 359.99°
Resolution: 0.01°
Accuracy: 0.03°
Frequency
Adjusting range: 40Hz ~ 65Hz
Resolution: 0.001 Hz
Accuracy: 0.002 Hz
Temperature drift: 0.5 PPM /
Long-term stability: 4 PPM/year
Work power
Single phase AC 220V± 15%, Frequency 50/60 Hz.
Volume and weight
Size: 420mmx320mmx155mm (LxW× H)
Weight: 12kg
Environmental conditions
Working temperature: 0 ~ 40
Relative humidity: ≤ 85%
Storage conditions: -30 ~ 60
Accuracy class |
0.02%, 0.05%, 0.1% |
Power supply |
Single phase AC 85-265V, 50/60 Hz |
AC Voltage output |
Range |
57.7V / 100 V / 220V / 380V, Switch automatically (max 500V or 600V) |
Adjustment resolution |
0.01%, 0.1%, 1%, 10%, |
Accuracy |
0.02% RG, 0.05% RG |
Stability |
Better than 0.01% RG/1min |
Distortion degree |
Better than 0.1% (not capacitive load) |
Load capacity |
25VA or 50VA |
Full load regulation rate |
Less than 0.01% RG |
Full load regulation time |
Less than 1ms |
Temperature drift |
8 PPM/°C |
Long-term stability |
60 PPM/year |
AC Current output |
Range |
0.1A / 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 100A/200A, Switch automatically(max 120A or 240A) |
Adjustment resolution |
0.01%, 0.1%, 1%, 10%, |
Accuracy |
0.02% RG, 0.05% RG |
Stability |
Better than 0.01% RG/1min |
Distortion degree |
Better than 0.1% (not capacitive load) |
Load capacity |
50VA, 100VA, 200VA, 500VA |
Full load regulation rate |
Less than 0.01% RG |
Full load regulation time |
Less than 1mS |
Temperature drift |
8 PPM/°C |
Long-term stability |
60 PPM/year |
Power output |
Active power accuracy |
0.02%, 0.05%, 0.1% |
Reactive power accuracy |
0.1% |
Stability |
Better than 0.01% RG/1min |
Phase angle |
Range |
0.000°-359.999° |
Output adjustment fineness |
10°, 1°, 0.1°, 0.01° as optional. |
Resolution |
0.001° |
Accuracy |
0.02°, 0.05° |
Power factor |
Adjusting range |
-1 ~ 0 ~ +1 |
Resolution |
0.0001 |
Accuracy |
0.0005 |
Frequency |
Range |
40.000-70.000 Hz |
Output adjustment fineness |
5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. |
Resolution |
0.001 Hz |
Accuracy |
0.002 Hz |
Temperature drift |
0.5 PPM/°C |
Long-term stability |
4 PPM/year |
Harmonic |
Harmonic times |
2nd-63th |
Adjustment resolution |
0.1% (Compared with fundamental wave) |
Harmonic content (Compared with fundamental wave) |
Voltage |
≤40% |
Current |
≤40% |
Phase |
0°-360.00° |
Functions |
Communication Port |
RS232 |
Programmable controlled |
Yes |
Key |
20pcs |
LCD |
6 inch TFT color touch display |
PC control software |
Optional |
Standard |
Standard |
IEC 62053-21,22, 23; IEC 60736; ANSI C12.20-2002;
JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019;
DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016 |
Safety |
Isolation protection |
IEC 61010-1:2001 |
Measurement Category |
300 V CAT III, 600 V CAT II |
Degree of protection |
IP20 |
Declaration of conformity |
CE & CNAS certified |
Mechanical parameters |