Single Phase Phantom Load Test Set

Product Details
Customization: Available
Application: Chemical Instrument, Mechanical Instrument, Length Instrument, Time Frequency Instrument, Electromagnetic Instrument, Radio Apparatus
Power: Electricity
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
>2000 square meters
  • Single Phase Phantom Load Test Set
  • Single Phase Phantom Load Test Set
  • Single Phase Phantom Load Test Set
  • Single Phase Phantom Load Test Set
  • Single Phase Phantom Load Test Set
  • Single Phase Phantom Load Test Set
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
Overview

Basic Info.

Model NO.
GF101
Certification
FDA, CE, IAF, CCC
Voltage Output
0-500V
Current Output
0-60A
LCD Display
With LCD Display
Customized
Customized
Range
57.7V / 100V / 220V / 380V / 750V, Range Switch Au
Adjust Fineness
0.01% Rg
Accuracy
Rg Is Higher Than 0.05%
Stability
Better Than 0.01% Rg / 1 Min
Distortion Degree
Better Than 0.1% (Not Capacitive Load)
Output Power
The Rated Each Phase Is 40 Va
Full Load Regulation Rate
Less Than 0.01% Rg
Full Load Regulation Time
Less Than 1ms
Temperature Drift
8 Ppm
Long-Term Stability
60 Ppm/Year
Transport Package
Aluminium Alloy Box
Specification
CE, ISO9001: 2008, IEC
Trademark
GFUVE
Origin
Beijing, China
HS Code
9030849000
Production Capacity
200units/Month

Product Description

GF101 120A Single Phase Phantom Load Test Set Program-Controlled Single-Phase Standard Power Source
Single Phase Phantom Load Test Set
Single Phase Phantom Load Test Set
Single Phase Phantom Load Test SetSingle Phase Phantom Load Test SetSingle Phase Phantom Load Test SetSingle Phase Phantom Load Test Set
 
Product Description

 


Application of Single Phase Phantom Load Test Set Program-Controlled Single-Phase Standard Power Source
It is suitable for power department, measuring department, quality control department, research units, and institutions of higher learning, and electric energy meter, power distribution terminals, power supply management, load control, power quality, reactive power compensation device and production of the enterprise and so on. It can be as single phase voltage source, current source and power source.
Main Functions and Features
To set up and take the load regulation of voltage, current, phase and frequency of the power factor;
To be set to 2 ~ 128 times of the amplitude and phase harmonics, and it can be added to the base wave in every harmonic output;
Voltage, current output a wide range, big power, high stability, waveform distortion degree is very small;
To have strong with load ability, and take capacitive, sensibility, resistance of composite type load or load and load regulation is higher than 0.01%;
To apply the 32 bit MPU + DSP + FPGA, powerful flexible;
To use hardware PID, fast response, the change of load will not cause output volatility;
Industrial frequency waves as high as 50000 points a week of the wave kneading, signal output without filter, precise output waveform, the harmonic output precision, harmonic distortion degree is small;
Range switching automatically;
To use software calibration, simple operation, stable and reliable;
To have the big screen, 320 X 240 LCD display, Chinese or English interface, operating simplely;
To have perfect over-current, over-voltage, heat, a shorts-and-opens, overload protection, automatic failure detection;
With RS232 interface, and PC connection;
To take place machine software, it can be output through the PC software of program.
Product Parameters

 


AC voltage output
Range: 57.7V / 100V / 220V / 380V / 750V, range switch automatically
Adjust fineness: 0.01% RG
Accuracy: RG is higher than 0.05%
Stability: Better than 0.01% RG / 1 min
Distortion degree: Better than 0.1% (not capacitive load)
Output power: The rated each phase is 40 VA
Full load regulation rate: Less than 0.01% RG
Full load regulation time: Less than 1mS
Temperature drift: 8 PPM /
Long-term stability: 60 PPM/year
AC current output
Range: 0.1/ 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 100A, range switch automatically
Adjust fineness: 0.01% RG
Accuracy: RG is higher than 0.05%
Stability: Better than 0.01% RG / 1 min
Distortion degree: Better than 0.1% (not capacitive load)
Output power: The rated each phase is 40 VA
Full load regulation rate: Less than 0.01% RG
Full load regulation time: Less than 1mS
Temperature drift: 8 PPM /
Long-term stability: 60 PPM/year
Phase angle
Adjusting range: 0 ~ 359.99°
Resolution: 0.01°
Accuracy: 0.03°
Frequency
Adjusting range: 40Hz ~ 65Hz
Resolution: 0.001 Hz
Accuracy: 0.002 Hz
Temperature drift: 0.5 PPM /
Long-term stability: 4 PPM/year
Work power
Single phase AC 220V± 15%, Frequency 50/60 Hz.
Volume and weight
Size: 420mmx320mmx155mm (LxW× H)
Weight: 12kg
Environmental conditions
Working temperature: 0 ~ 40
Relative humidity: ≤ 85%
Storage conditions: -30 ~ 60
Accuracy class 0.02%, 0.05%, 0.1%
Power supply Single phase AC 85-265V, 50/60 Hz
AC Voltage output
Range 57.7V / 100 V / 220V / 380V, Switch automatically (max 500V or 600V)
Adjustment resolution 0.01%, 0.1%, 1%, 10%,
Accuracy 0.02% RG, 0.05% RG
Stability Better than 0.01% RG/1min
Distortion degree Better than 0.1% (not capacitive load)
Load capacity 25VA or 50VA
Full load regulation rate Less than 0.01% RG
Full load regulation time Less than 1ms
Temperature drift 8 PPM/°C
Long-term stability 60 PPM/year
AC Current output
Range 0.1A / 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 100A/200A, Switch automatically(max 120A or 240A)
Adjustment resolution 0.01%, 0.1%, 1%, 10%,
Accuracy 0.02% RG, 0.05% RG
Stability Better than 0.01% RG/1min
Distortion degree Better than 0.1% (not capacitive load)
Load capacity 50VA, 100VA, 200VA, 500VA
Full load regulation rate Less than 0.01% RG
Full load regulation time Less than 1mS
Temperature drift 8 PPM/°C
Long-term stability 60 PPM/year
Power output
Active power accuracy 0.02%, 0.05%, 0.1%
Reactive power accuracy 0.1%
Stability Better than 0.01% RG/1min
Phase angle
Range 0.000°-359.999°
Output adjustment fineness 10°, 1°, 0.1°, 0.01° as optional.
Resolution 0.001°
Accuracy 0.02°, 0.05°
Power factor
Adjusting range -1 ~ 0 ~ +1
Resolution 0.0001
Accuracy 0.0005
Frequency
Range 40.000-70.000 Hz
Output adjustment fineness 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution 0.001 Hz
Accuracy 0.002 Hz
Temperature drift 0.5 PPM/°C
Long-term stability 4 PPM/year
Harmonic
Harmonic times 2nd-63th
Adjustment resolution 0.1% (Compared with fundamental wave)
Harmonic content (Compared with fundamental wave)
Voltage ≤40%
Current ≤40%
Phase 0°-360.00°
Functions
Communication Port RS232
Programmable controlled Yes
Key 20pcs
LCD 6 inch TFT color touch display
PC control software Optional
Standard
Standard IEC 62053-21,22, 23; IEC 60736; ANSI C12.20-2002;
JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019;
DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016
Safety
Isolation protection IEC 61010-1:2001
Measurement Category 300 V CAT III, 600 V CAT II
Degree of protection IP20
Declaration of conformity CE & CNAS certified
Mechanical parameters

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More