Portable Test-200 Electronic Measuring Instrument 200A C

  • Audited Supplier
  • 14 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Versatile Output Capabilities: Max current 250A, AC voltage 250V, DC voltage 300V, and 2KVA capacity.
  • Dual Protection System: Features electronic overload protection and software protection for safety.
  • Portable & Durable Design: Aluminum alloy body with PC panel, weighing only 22.5kg for easy site testing.
  • Wide Application Scope: Ideal for circuit breaker testing, contact resistance, and relay testing.
  • Integrated Stopwatch: Built-in high precision stopwatch with range 0.0000-99999S and 0.1mS resolution.
  • Multiple Output Channels: Includes DC auxiliary output 0-220V and binary input/output contacts.
  • Certified Quality: Complies with ISO9001, CCC, EMC, and IEC61000/61010/61326 standards.

Product Images of Portable Test-200 Electronic Measuring Instrument 200A C

Portable Test-200 Electronic Measuring Instrument 200A C
Portable Test-200 Electronic Measuring Instrument 200A C pictures & photos
Portable Test-200 Electronic Measuring Instrument 200A C
Portable Test-200 Electronic Measuring Instrument 200A C pictures & photos
Portable Test-200 Electronic Measuring Instrument 200A C
Portable Test-200 Electronic Measuring Instrument 200A C pictures & photos
Portable Test-200 Electronic Measuring Instrument 200A C
  • Portable Test-200 Electronic Measuring Instrument 200A C
  • Portable Test-200 Electronic Measuring Instrument 200A C
    Portable Test-200 Electronic Measuring Instrument 200A C
  • Portable Test-200 Electronic Measuring Instrument 200A C
    Portable Test-200 Electronic Measuring Instrument 200A C
  • Portable Test-200 Electronic Measuring Instrument 200A C
    Portable Test-200 Electronic Measuring Instrument 200A C

Find Similar Products

Product Description

TEST-200200A PORTABLE PRIMARY CURRENT INJECTION TEST KIT

TEST-200 200A primary current injection test kit adopts ARM Chip to control its output process and large capacity of toroidal transformers. It is equipped with current meter; it can show primary current value, second current value, the action time and voltage value. Packing is used as aluminum alloy body with PC panel. LCD screen display single-phase protective relay test device of voltage and current output stopwatch; a full isolation, adjustable AC and DC voltage, AC direct current; an adjustable DC voltage and an adjustable AC voltage; output circuit with double overload protection, high output capacity, small size, light weight, high reliability.
Primary Injection Kit Compact Model TEST-200 is designed to operate on single phase 230/240 Volts AC 50/60 Hz. to develop smooth & continuous test current. The test set gives high current output at low cost and with inherent safety at minimum precaution. TEST-200 is mainly applied to Circuit Breaker testing in the power system, contact resistance test and relay test.
Portable Test-200 Electronic Measuring Instrument 200A CPortable Test-200 Electronic Measuring Instrument 200A CPortable Test-200 Electronic Measuring Instrument 200A C
 

FEATURES

DC Voltage output up to 300V;

AC Voltage output up to 250V;

Max current output up to 250A;

Built-in digital timer resolution 1ms;

Thermal and short-circuit protection;

Permanent current up to 200 A, 2KVA;

Built-in digital ammeter 0.2% accuracy;

Small size, light weight, easy to test on-site;

Suite for all kinds of overcurrent relay testing;

With high precision 0.0000-99999S Stopwatch;

Current injection continuous output from 0-50A;

Have one channel DC Auxiliary Output from 0 to 220V;

 

FEATURES

DC Voltage output up to 300V;

AC Voltage output up to 250V;

Max current output up to 250A;

Built-in digital timer resolution 1ms;

Thermal and short-circuit protection;

Permanent current up to 200 A, 2KVA;

Built-in digital ammeter 0.2% accuracy;

Small size, light weight, easy to test on-site;

Suite for all kinds of overcurrent relay testing;

With high precision 0.0000-99999S Stopwatch;

Current injection continuous output from 0-50A;

Have one channel DC Auxiliary Output from 0 to 220V;

 

PARAMETERS

Electrical parameters
Accuracy ±0.5%
Power Supply (AC) 220V±10%·2000VA, 50Hz/60Hz or110V±10%·2000VA, 50Hz/60Hz
Current Output (AC) 200A·5V or 100A·10V
Capacity 2KVA
The current output waveform distortion ≤5%
Dual protection overload electronic protection and software protection
Primary current
Range 0-250A
Resolution 0.1A
Accuracy <0.5% RG
AC Voltage Output
Range 0-250V AC
Resolution 0.1V
Accuracy <0.2% RG
DC Voltage Output
range 0-300V DC
Resolution 0.1V
Accuracy <0.5% RG
Current Output duration
200A range 200A  1-2minutes
100A  3-6minutes
50A  Continuous
10A range 10A  Continuous
Stopwatch
Range 0.0000-99999S
Resolution 0.1mS
Accuracy ±5 words
Max input voltage
(With contact and potential input)
DC 250V
Ammeter
Range Inside 0.000-250.0A
Outside 0.000-6.000A(AC or DC)
Accuracy <0.2%
Voltmeter
Range 0.0-600.0V(AC or DC)
Accuracy <0.2%
Measuring mode AC True RMS
DC Average value
Auxiliary Contacts
Binary input/output one, AC250V*1A or DC120V*1A
DC Auxiliary Output
Range 0-110V DC, max 0.5A; 110-220V DC, max 0.5A
Interface
Serial interface RS232
LCD 320*240 Greenlight LCD display
Resistor
Resistance 0.5Ω-2.5kΩ
Capacitor 10 μF, max voltage 450 V AC
Standard
Standard 2006/95/EC, EMC 2004/108/EC, IEC61000, IEC61010, IEC 61326
Mechanical parameters
Dimensions (W×D×H) (mm) 340×270×250
Weight(kg) 22.5
Environmental conditions
Operating Temperature -10°C to 50°C
Storage temperature -40°C to 70°C
Humidity range Relative humidity 5 ... 95 %, non-condensing

SELECTION GUIDE

Model Accuracy Primary Current Ammeter(0-6A) Timer Power Injection Current time Dimension(W×D×H) (mm) Weight Remark
TEST-200 0.50% 0-200A YES YES 2KVA 200A: 2-3min;
100A:3-6min
340×270×250 22.5KG Integrated structure
TEST-901 0.50% 0-1100A YES YES 5KVA 1000A: 2-3min;
500A:3-6min
430×260×260 25KG Integrated structure
TEST-902 0.50% 0-2200A YES YES 12KVA 2000A:2-3min;
1000A:3-6min
360×300×295 and 320×300×300 35KG+15KG Fission structure
TEST-903 0.50% 0-3300A YES YES 15KVA 3000A: 2-3min;
1500A:3-6min
380×350×360 and 340×290×420 48KG+42KG Fission structure
TEST-905 0.50% 0-5500A YES YES 30KVA 5000A:2-3min;
2500A:3-6min
430×430×445 and 550×450×600 68KG+55KG Fission structure


 

About the Supplier

Watch Video
Watch Video
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.

About Our Factory & Business Background

Address
Bldg. 2-1111, Joy Mansion, No. 99 Chaoyang North Road, Chaoyang District, Beijing, China
Terms of Payment
LC, T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, CIF, FCA, EXW
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
TIANJING

Our Production Capability & Technical Expertise

Main Products
Current Transformer, Energy Meter Calibration, Power Quality Analyzer, Test Equipment, CT PT Analyzer, Relay Test Equipment, Split Core Current Transformer, Current Probe, Voltage Transformer, Power Meter

Our Industry Experience & Global Business Record

Export Year
2010-08-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the maximum current output of the TEST-200?
The maximum current output is up to 250A, with a permanent current of 200A at 2KVA capacity.
What are the voltage output ranges?
It provides AC voltage output up to 250V and DC voltage output up to 300V.
What protections are built into the TEST-200?
It features dual protection including electronic overload protection and software protection against thermal and short-circuit risks.
What are the typical applications for this kit?
It is mainly applied to circuit breaker testing, contact resistance testing, and relay testing in power systems.
What is the duration for continuous current output?
At 50A, it supports continuous output. At 100A, it lasts 3-6 minutes. At 200A, it lasts 1-2 minutes.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Product Groups

Product Catalogs