Test Bench Power Meter Calibration Instrument Gf6018 Multimeter Calibrator

Product Details
Customization: Available
Application: Mechanical Instrument, Electromagnetic Instrument
Power: Electricity
Gold Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
>2000 square meters
  • Test Bench Power Meter Calibration Instrument Gf6018 Multimeter Calibrator
  • Test Bench Power Meter Calibration Instrument Gf6018 Multimeter Calibrator
  • Test Bench Power Meter Calibration Instrument Gf6018 Multimeter Calibrator
  • Test Bench Power Meter Calibration Instrument Gf6018 Multimeter Calibrator
  • Test Bench Power Meter Calibration Instrument Gf6018 Multimeter Calibrator
  • Test Bench Power Meter Calibration Instrument Gf6018 Multimeter Calibrator
Find Similar Products

Basic Info.

Model NO.
GF6018
Voltage Output
0-1100V
Current Output
0-24A
LCD Display
With LCD Display
Customized
Customized
Weight
12kg
Accuracy Class
0.05%
Communication Port
RS232 Interface
Relative Humidity
Less Than 85%Rh
Size
440X450X160mm
Fequency
50/60Hz
LCD
6.4 Inch
AC/DC U Range
0-1100V
AC/DC I Range
0-24A
Frequency
45-65Hz
Transport Package
Standard Export Carton
Specification
CE, ISO9001: 2008, IEC
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
200PCS/Month

Product Description

Application of GFUVE latest product Power plant test and measurement instrument GF6018 Multimeter Calibrator,with CE,ISO9001:2000 approved,excellent working performance
Test Bench Power Meter Calibration Instrument Gf6018 Multimeter CalibratorTest Bench Power Meter Calibration Instrument Gf6018 Multimeter CalibratorTest Bench Power Meter Calibration Instrument Gf6018 Multimeter Calibrator
GF6018 Multimeter Calibrator is suitable for power plant and substation work area of grid companies, make try department and the instrument classes, and national levels measuring and testing institutions, railway, petroleum, chemical industry and other large industrial and mining enterprises, scientific research units, etc.

Introduction
GF6018 Multimeter Calibrator is according to verification regulation JJG124-2005 "ammeter, voltmeter, power meter and resistance meter calibration regulations of the requirements and design 0.05 magnitude AC and DC standard sources.The source of the signals of the DSP and 16 high-speed digital-to-analog converters can control of the sine wave, distortion wave source.The display users graphics standard 240 X 128 LCD monochrome screen, chart characters, showed clear.Circuit design perfect protection, reliable operation, easy to operate.

Main Functions and Features
1.GF6018 Multimeter Calibrator, consists of a single-phase AC voltage standard resource, current standard resource and DC voltage, current standard resource of standard resource.
2.Have calibration function, which can accord to the standard of external value, fixed standard resource output values.
3.The setting of the range for verification 1999 (9), 3999 (9) a display of the digital multimeter.
4.Manual and semi-auto inspection 0.2 % and below levels of digital multimeter, an analogue meter installation type digital instrument, including DC analog output of digital instrument.
5.To generate containing 2 ~ 31 harmonic wave distortion, the harmonic number, number, amplitude and phase of the harmonic wave to base wave all can be programmed control.
6.With RS232 interface and large capacity non-volatile memory, it can store 300 blocks inspected meter test data.Through the PC software, the PC controls this device automatic and manual inspection, and the results are processing and management.

Technical Data
AC output
Voltage range:200 mV, 400 mV, 2 V, 4 V, 20 V, 100 V, 200 V, 500 V, 1000 V;
Current range:20μA, 40μA, 200 μA, 400 μA, 2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A;
Adjusting range 0 ~ 120% (1000 V voltage except);
Adjust fineness 5 X 10-5;
Voltage, current output capacity 20 VA;
Voltage, current adjustment for accuracy
±(0.03% RD + 0.02% FS);
Voltage, current output stability ≤0.01% / 60 s;
Voltage, current waveform distortion degree ≤0.3%;
Sine wave output frequency range (45-65) N Hz (N = 1, 2, 3, ...31);
Sine wave frequency output fineness 0.001 N Hz (N = 1, 2, 3, ...31);
Phase adjustment range 0 ~ 359.99 °;
Phase adjust fineness 0.01 °;
Harmonic output 2 ~ 31, range 0 ~ 20% (base wave ratings);
Harmonic phase fineness 0.01 °N (N for harmonic frequency, N = 2 and 4, ...31);
Output can also contains multiple harmonics, also can set base wave amplitude is 0, output power frequency than the sine wave.
DC output
Voltage range:200 mV, 400 mV, 2 V, 4 V, 20 V, 40 V, 100 V, 200 V, 400 V, 1000 V;
Current range:20μA, 40μA, 200 μA, 400 μA, 2 mA, 4 mA, 20 mA, 40 mA, 0.2 A, 1 A, 2.5 A, 5 A, 10 A, 20 A;
Voltage, current, the adjusting range 0 ~ 120% (1000 V voltage except);
Voltage, current adjust fineness 5 X 10-5;
Voltage output capacity 20 W;
Current output capacity of 30 W;
Voltage, current adjustment for accuracy ±(0.03% RD + 0.02% FS);
Voltage, current output stability ≤0.01% / 60 s;
Voltage, current output ripple ≤1%.
Frequency output
Sine wave output range (using AC voltage, current output provide)
(45-65) N Hz (N = 1, 2, 3, ...31);
Fineness 0.001 N Hz (N = 1, 2, 3, ...31);
The setting accuracy 5 X 10-5;
Point 1 kHz square wave frequency output, 5 kHz, 10kHz, 50kHz, 100kHz, 200kHz, 1000kHz.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More