Customization: | Available |
---|---|
Display: | Digital |
Installation: | Lab or Field |
Still deciding? Get samples of US$ 25800/Set
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The GF302D portable three phase energy meter test board consists of an integrated three phase 120A current source and 600V voltage source and a class 0.04 three phase electronic reference standard meter.
The energy meter test board is particularly designed for analysis of complete metering installations and local mains conditions. The meter test bench offers high functionality combined with an excellent menu guided operation via built-in thirty keys and colored 7" touch LCD-display.
Electrical parameters | |
---|---|
Accuracy | 0.04% |
Power Supply | Single phase AC 85-265V, frequency 50/60Hz. |
AC Voltage Output | |
Range(U1,U2,U3) | 69.3V, 120V, 240V, 480V( optional); max 400V |
Adjustment range | (0-120)%RG(1) |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | 0.01%/120s |
Distortion | 0.2% (Non-capacitive load) |
Output load | each phase 25VA |
Accuracy | 0.05%RG or 0.02%RG |
AC Current Output | |
Range(I1,I2,I3) | 200mA, 1A, 5A, 20A, 100A; max 125A |
Adjustment range | (0-120)%RG |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | <0.01%/120s |
Distortion | ≤0.2% (Non-capacitive load) |
Output load | 100VA |
Accuracy | 0.04%RG |
Power Output | |
Active power output stability | <0.01%RG/120s |
Reactive power output stability | <0.02%RG/120s |
Active power measuring accuracy | 0.04%RG |
Reactive power measuring accuracy | 0.1%RG |
Phase Output | |
Output adjustment range | 0°-359.999° |
Output adjustment fineness | 10, 1, 0.1, 0.01 as optional. |
Resolution | 0.01° |
Accuracy | 0.02° |
Power Factor | |
Adjustment range | -1 ~ 0 ~ 1 |
Resolution | 0.0001 |
Measurement accuracy | 0.0005 |
Frequency Output | |
Adjustment range | 40Hz-70Hz |
Output adjustment fineness | 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. |
Resolution | 0.001Hz |
Accuracy | 0.002Hz |
Voltage /Current/Harmonic Setting Output | |
Harmonic number | 2-51times |
Harmonic content | 0-40% |
Harmonic phase | 0-359.99 |
Harmonic setting accuracy | (10%±0.1%)RD(2) |
Power Energy Measurement Error | |
Active power energy | 0.04%RG |
Reactive power energy | 0.1%RG |
Power Pulse Output | |
Power pulse type | active pulse, reactive pulse |
Active power pulse output | 5V, 10mA |
Power Pulse Input | |
Energy pulse type | support active and reactive pulse, the highest frequency power pulse input is 180K. |
Communication Port | |
Communication Port | RS232, USB2.0 |
Safety | |
Isolation protection | IEC 61010-1:2001 |
Measurement Category | 300 V CAT III, 600 V CAT II |
Degree of protection | IP20 |
Declaration of conformity | CE certified |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 445x460x158 |
Weight (kg) | 27 |
(1) RG means range, the same as below; (2) RD means the setted harmonic content, harmonic can be a single output, also multiple output. |