• Lzck322-10 Low Voltage Split Core 400/5A Current Transformer
  • Lzck322-10 Low Voltage Split Core 400/5A Current Transformer
  • Lzck322-10 Low Voltage Split Core 400/5A Current Transformer
  • Lzck322-10 Low Voltage Split Core 400/5A Current Transformer
  • Lzck322-10 Low Voltage Split Core 400/5A Current Transformer
  • Lzck322-10 Low Voltage Split Core 400/5A Current Transformer

Lzck322-10 Low Voltage Split Core 400/5A Current Transformer

Application: Electronic
Type: Current Transformer
Phase: Single
Operation Condition: Indoor
Usage: Protection, Measurement
Winding Form: Single Layer & Tightly Wound Type
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
LZCK322-10
Insulating Medium
Epoxy Resin
Installation
Strut Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Standards
IEC60044-1; IEC 61869-2; ANSI C57.13; Ntc 2205; G
Rated Primary Current
30-600A
Rated Load
<10va
Rated Frequency
50Hz or 60Hz
Rated Secondary Current
5A or 1A
Transport Package
Standard Carton Packaging
Specification
IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
50000 Sets/Month

Product Description

LZCK322-10 11KV 33KV HIGH VOLTAGE SPLIT CORE CT CURRENT TRANSFORMER

LZCK series split core current transformer is suitable forcurrent measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system.It is widely used in compact fully insulated ring network switchgears such as ABB-Safe Ring/Safe Plus...and cable distribution boxes.The transformer can be directly installed at the inlet andoutlet cables.The slice is imported silicon material. Thesemicircular ring core and secondary windings arevacuum poured by insulated resin.

REQUEST A QUOTE
Quick Links: Download Catalogue
 

 

P1, P2 is primary polarity terminal, S1, S2 is secondary polarity terminal.
P2, S2 is homonymous terminals (subtractive polarity).

PARAMETERS

Technical parameters
Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006
Rated primary current 30-600A
Rated load ≤10VA
Rated frequency 50Hz or 60Hz
Rated secondary current 5A or 1A
Rated short-time thermal current 40kA, 1S
Rated continuous thermal current 120%I1n
Secondary winding power-frequency voltage 3kV, 1min
Instrument security factor FS≤10
Mechanical parameters
Dimensions (W×D×H) (mm) φ50xφ110x52
Weight (kg) 1.6
Operating conditions
Operating temperature -35°C to +55°C
Daily average temp <+40°C
Altitude <3500 meters
Condition No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.

TECHNICAL DATA

Type LZCK322-10 LZCK322-10
Purpose Measuring current transformer Protection current transformer
Ratio Accuracy class and rated load(VA) Accuracy class and rated load(VA)
I1/I2 0.5 1 3 10P15 10P10 10P5
30/1   1 1.5      
50/1   1 2     1.25
75/1   1.5 2.5   1 2
100/1 2 2.5 3   1.5 2.5
200/1 2.5     1.25 2.5  
300/1 3.75     1.25 2.5  
400/1 7.5     1.25 2.5  
500/1 10     1.25 3  
600/1 10     1.5 3  
50/5     2.5      
75/5     2.5      
100/5 2.5          
200/5 3.75          
300/5 5          
400/5 7.5       2.5  
500/5 7.5       2.5  
600/5 10       3.75  

SELECTION GUIDE

 Model Primary rated current Rated load Aperture (mm) Description (mm) Weight (kg) Material Water-proof
LZCK-55 100-1500A ≤10VA φ55 180×138×52 2 PC  IP65
LMCK185-10 300-3000A ≤25VA φ185 350×283×55 4.5 PC  IP65
LZCK310-10 300-600A ≤10VA φ50 φ50 x φ110 x 32 1 Resin silicon case (option)
LZCK322-10 30-600A ≤10VA φ50 φ50 x φ110 x 52 1.6 Resin silicon case (option)
LZCK350-10 20-600A ≤25VA φ50 φ50 x φ110 x 105 3.1 Resin silicon case (option)
LZCG530-10 30-600A ≤20VA φ45 φ45 x φ120 x 65 2.1 Resin silicon case (option)






 


Lzck322-10 Low Voltage Split Core 400/5A Current Transformer
Lzck322-10 Low Voltage Split Core 400/5A Current Transformer
Lzck322-10 Low Voltage Split Core 400/5A Current Transformer
Lzck322-10 Low Voltage Split Core 400/5A Current Transformer
Lzck322-10 Low Voltage Split Core 400/5A Current Transformer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now