• 1va-80va Voltage Transformer and Current Transformer Burden Test Set
  • 1va-80va Voltage Transformer and Current Transformer Burden Test Set
  • 1va-80va Voltage Transformer and Current Transformer Burden Test Set
  • 1va-80va Voltage Transformer and Current Transformer Burden Test Set
  • 1va-80va Voltage Transformer and Current Transformer Burden Test Set
  • 1va-80va Voltage Transformer and Current Transformer Burden Test Set

1va-80va Voltage Transformer and Current Transformer Burden Test Set

Application: Instrument, Transformer Burden Test Set
Type: Voltage Transformer and Current Transformer Burden
Phase: Single
Operation Condition: Indoor
Usage: Protection, Measurement
Magnetic Circuit Structure: Combined Type
Samples:
US$ 10000/Set 1 Set(Min.Order)
| Request Sample
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF106FY
Voltage Transformation Principle
Electromagnetic Type
Names
Current Transformer Burden Test Set
Applications
Voltage Transformer and Current Transformer Burden
CT Burden
0-80va
PT Burden
0-200va
Weight
20kg
Class
3
Cosφ
0.8 and 1
Rated Current
1A and 5A
Transport Package
Standard Export Wooden Carton
Specification
GF106FY-1, GF106FY-2
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
200PCS/Month

Product Description

GF106FY Voltage Transformer and Current Transformer Burden Test Set from 1VA to 80VA
 

GF106FY CT PT Burden Test Set

GF106FY-1 CT Burden
1va-80va Voltage Transformer and Current Transformer Burden Test Set

 

 

TECHNICAL DATA

Standard No

IEC 60044-1

Rated Current

5A; 1A

Power Factor

and Rated Capacity

COSФ=0.8: 2.5/ 3.75/ 5/ 6.25/ 7.5/ 10/ 12.5/ 15/ 20/ 30/ 40/ 50/ 60VA

COSФ=1.0: 2.5/ 3.75/ 5/ 6.25/ 7.5/ 10VA

Accuracy Class

±3%

Operation Frequency

50Hz

Operating Range

(1%-200%) In

Test Cable Resistance

0.06Ω

Withstand Voltage

2000V 1min

Operating Condition

Temperature: 10 oC ~ +40 oC

Relative Humidity (RH): up to 85% (max 90%)


GF106FY-2 PT Burden
1va-80va Voltage Transformer and Current Transformer Burden Test Set

 

 

TECHNICAL DATA

Standard No

IEC 60044-2

Rated Voltage

120V, 115V, 115/√3V

Rated Capacity

1.25VA, 2.5VA, 5VA, 10VA, 20VA, 40VA, 80VA

Total Capacity

158.75VA

Accuracy Class

±3%

Power Factor

COSΦ=0.8,1.0

Operation Frequency

50Hz

Operating Range

(20%-120%) Un

Withstand Voltage

2000V 1min

Operating Condition

Temperature: -5 oC ~ +40 oC

Relative Humidity (RH): up to 85% (max 90%)

 