Test Voltage | |
Range | 0V - 600V |
Error | ± 0.05% (30V - 600V) ± 0.1% (5V - 30V) |
Harmonic | 2 nd -- 63 st |
Test Current | |
Range (direct connection) | 20mA - 20A |
Error (direct connection) | ± 0.05% (100mA - 20A) ± 0.1% (20mA - 100mA) |
Range (Clamp CT) | 10mA - 3000A |
Error (Clamp CT) | ± 0.2% (100mA - 3000A) ± 0.5% (10mA - 100mA) |
Harmonic | 2 nd -- 63 st |
Power measure error | |
Active power (direct connection) | ± 0.05% (0.1A - 20A) ± 0.1% (0.02A - 0.1A) |
Reactive power (direct connection) | ± 0.1% (0.1A - 20A) |
Energy measure error | |
Active energy (direct connection) | ± 0.05% (0.1A - 20A) ± 0.1% (0.02A - 0.1A) |
Reactive energy (direct connection) | ± 0.1% (0.1A - 20A) |
Phase angle | |
Range | 0º - 360º |
Error | ± 0.05º |
Frequency | |
Range | 45Hz - 65Hz |
Pulse output | |
Energy constant | 180000imp/kWh\1800imp/kWh\18imp/kWh |
Pulse ratio | 1: 1 |
Output level | 5V |
Pulse input | |
Input channel | 1 |
Input level | 5 - 24V |
Input frequency | Max. 2MHz |
Display | |
Resolution | 6" TFT (640× 480) |
Function | |
Vector diagram | Yes |
Waveform | Yes |
Energy accumulation | Yes |
Communication port | RS232 |
Communication with PC | yes |
Other | |
Voltage Supply way | External power |
Voltage Supply | 220V ± 10%, 50/60Hz ± 2Hz |
Ambient temperature | -10 -- 40degrees |
Relative humidity | 30% -- 80% |
Dimensions (W × H × D) (mm) | 390× 200× 160 |
Weight (kg) | 3kg |