• Power Plant Testing Device 20A Program-Controlled Three Phase AC Power Sources
  • Power Plant Testing Device 20A Program-Controlled Three Phase AC Power Sources
  • Power Plant Testing Device 20A Program-Controlled Three Phase AC Power Sources
  • Power Plant Testing Device 20A Program-Controlled Three Phase AC Power Sources
  • Power Plant Testing Device 20A Program-Controlled Three Phase AC Power Sources
  • Power Plant Testing Device 20A Program-Controlled Three Phase AC Power Sources

Power Plant Testing Device 20A Program-Controlled Three Phase AC Power Sources

Certification: ISO9001, CCC, CNAS
Protection: Shock Resistance
Installation: Hanging
Housing: UPR
Transport Package: Standard Export Carton
Specification: CE, ISO9001: 2000
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF303
Trademark
GFUVE
Origin
Beijing China
Production Capacity
200PCS/Month

Product Description

GF303 20A high precision Program-Controlled Three Phase ac portable power sources
Power Plant Testing Device 20A Program-Controlled Three Phase AC Power Sources

Power Plant Testing Device 20A Program-Controlled Three Phase AC Power Sources
Power Plant Testing Device 20A Program-Controlled Three Phase AC Power SourcesIt is suitable for power department, measuring department, quality control department, research units, and institutions of higher learning, and electric energy meter, power distribution terminals, power supply management, load control, power quality, reactive power compensation device and the production of enterprise etc.

Functions and Features
To set up and take the load regulation of voltage, current, phase angle, frequency and power factor etc; As a AC current source, AC voltage source or power source;
To set 2 ~ 128 times of the amplitude and phase harmonics, and it can be added to the base wave in every harmonic output;

Frequency value is adjustable (AB and phase C);
Voltage, current output a wide range, big power, high stability, waveform distortion degree is small;
Strong with load ability, but it can take capacitive, sensibility, resistance of composite type load or load and load regulation is higher than 0.01%;
To apply the 32 bit MPU + DSP + FPGA, powerful flexible;
To use hardware PID, fast response, the change of load will not cause output volatility;
Industrial frequency waves as high as 50000 points a week of the wave kneading, signal output without filter, precise output waveform, the harmonic output precision, harmonic distortion degree is small;
Range switching automatically

GF-303 Program-controlled three-phase standard portable power sources uses software calibration, simple operation, stable and reliable;
To have big screen, 320 X 240 LCD display, Chinese or English interface, operating simplely;
GF-303 Program-controlled three-phase standard power source have perfect over-current, over-voltage, heat, a shorts-and-opens, overload protection, failure detection automatically;
With RS232 interface, and PC connection
To take place machine software, it can be output through the PC software program;
Electrical parameters
Accuracy class  0.05%, 0.1%
Power supply Single phase AC 85V-265V, 50/60 Hz
AC Voltage output
Range (U1, U2, U3 phase) 57.7V/100V/220V/380V, switch automatically (max 420V)
Adjustment resolution 0.01%, 0.1%, 1%, 10%,
Accuracy 0.05% RG
Stability 0.005% RG/1min
Distortion degree better than 0.1% (not capacitive load)
Load Capacity 25VA
Full load regulation rate Less than 0.01% RG
Full load regulation time Less than 1mS
Temperature drift 8 PPM / °C
Long-term stability 60 PPM/year
AC Current output
Range (I1, I2, I3 phase) 0.1/0.25A/0.5A/1A/5A/10A/20A, switch automatically
Adjustment resolution 0.01%, 0.1%, 1%, 10%, 
Accuracy 0.05% RG
Stability 0.005% RG/1min
Distortion degree better than 0.1% (not capacitive load)
Load capacity 25VA
Full load regulation rate Less than 0.01% RG
Full load regulation time Less than 1mS
Temperature drift 8 PPM/°C
Long-term stability 60 PPM/year
Power output
Active power accuracy 0.05%
Reactive power accuracy 0.1%
Stability 0.005% RG/1min
Phase
Range 0°-359.99°
Adjustment resolution 0.01°, 0.1°, 1°, 10°
Accuracy 0.03°
Power factor  
Adjusting range -1 to 0 to +1
Resolution 0.0001
Accuracy 0.0005
Frequency
Range 40-65Hz or 40-400Hz (option)
Adjustment resolution 0.001Hz, 0.01Hz, 0.1Hz, 1Hz
Accuracy 0.002Hz
Temperature drift 0.5PPM/°C
Long-term stability 4 PPM/year
Harmonic
Harmonic times 2-128
Adjustment resolution 0.1% (compared with fundamental wave)
Harmonic content (compared with fundamental wave)
Voltage ≤40%
Current ≤40%
Phase 0°-360°
Capacitive load capacity
0 - 280 V 1uF 
280 - 420 V 0.6uF
Mechanical parameters
Dimensions (W×D×H) (mm) 450x380x160
Weight (kg) 18
Environmental conditions
Working temperature 0°C to 40°C
Storage conditions -30°C to 60°C
Relative humidity ≤85%