Customization: | Available |
---|---|
Application: | Instrument |
Type: | Current Transformer |
Still deciding? Get samples of US$ 158/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Theory
In electrical and electronic engineering, a split type current transformer is an electrical device with jaws which open to allow clamping around an electrical conductor. This allows measurement of the current in a conductor without the need to make physical contact with it, or to disconnect it for insertion through the probe. split type current transformers are typically used to read the magnitude of alternating current (AC) and, with additional instrumentation, the phase and waveform can also be measured. Some clamps meters can measure currents of 1000 A and more.
Applications
The round jaw design on the P50 Series AC split type current transformer along with the high content nickel metal core makes them well suited for power quality applications where high accuracy and low phase shift along with wide frequency are important. Measurement range is 1mA to 1200A.
The P50 split type current transformer is a general purpose 1000A AC current clamp designed for use with DMMs, loggers and other instruments that have a current input. It has a 1000:1 ratio and output of 1mA per amp or 1mV per amp measured in the jaw. The P50 has an integral 2.5m lead terminated. The rounded jaw design on this current clamp makes it well-suited for power applications where high accuracy 0.1% and low phase shift and wide frequency response are important.
Power quality measuring
Large industrial loads
Measuring around cable bundles
Power load monitoring
Waveform analysis
Energy meter calibrator
Power monitor
Phase Angle meter
Resistance tester
Features
Measurement range of 1mA to 1200A AC
Large jaw opening accommodates conductors up to two 500kcmil
Improved ergonomic design and easy operation
High content nickel metal core
Conforms to EN 61010, 600V CAT III
Low phase shift for power measurement
Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters
UL, CE mark
Electrical parameters |
|
Ratio |
1000: 1 or 2000:1 (customized) |
Accuracy class |
0.1%, 0.2%, 0.5% |
Primary current |
0 - 1000A AC |
Secondary output |
1mV/A AC, 5mV/A, 1mA/A, 0.5mA/A or (customized) |
Max. Cont. Input current |
1200A |
Over voltage category |
CAT III 600V |
Output signal |
333mV, 500mV,1V,2V,5V, 1A, 5A AC at nominal input current |
Accuracy (1000A Range) |
|
0-10A |
≤0.5% |
10-100 |
≤0.2% |
10-1200A |
≤0.1% |
Phase Shift(1000A Range) |
|
0-10A |
≤0.5° |
10-100 |
≤0.2° |
100-1200A |
≤0.1° |
Electrical parameters - continued |
|
Frequency range |
40Hz-20MHz |
Dielectric strength |
3KV 50Hz/60Hz at 1 minute |
Temperature range |
-20°C to +55°C |
Output |
2.5 meter cable with D01 connector |
Max. voltage not insulated conductors |
600 V |
Standard |
EN 61010-1, EN 61010-2-032, IEC60044-1 |
Installation |
clamp type |
Output mode |
lead output(2.5m) |
Mechanical parameters |
|
Dimensions (L x W x H) (mm) |
102.9 x 219.6 x 28 |
Weight (g) |
550 |
Holding wire diameter (mm) |
φ50 |
Max. jaw opening (mm) |
50 |
Color |
Gray or Blue |
Material |
PC+ABS+Polycarbonate, UL94 V0 |
SELECTION GUIDE
Model |
Rate Current |
Max Current |
Secondary Current |
Coil Ratio |
Burden Resistance |
Accuracy |
P50-200 |
200A |
240A |
5A |
40:1 |
2.5VA |
0.5% |
P50-300 |
300A |
360A |
5A |
60:1 |
2.5VA |
0.5% |
P50-400 |
400A |
480A |
5A |
80:1 |
2.5VA |
0.5% |
P50-500 |
500A |
600A |
5A |
100:1 |
2.5VA |
0.5% |
P50-600 |
600A |
720A |
5A |
120:1 |
2.5VA |
0.5% |
P50-800 |
800A |
960A |
5A |
160:1 |
2.5VA |
0.5% |
P50-1000 |
1000A |
1200A |
5A |
200:1 |
2.5VA |
0.5% |
P501-100 |
100A |
120A |
1A |
100:1 |
customized |
0.5% |
P501-200 |
200A |
240A |
1A |
200:1 |
customized |
0.5% |
P501-300 |
300A |
360A |
1A |
300:1 |
customized |
0.2% |
P501-400 |
400A |
480A |
1A |
400:1 |
customized |
0.2% |
P501-500 |
500A |
600A |
1A |
500:1 |
customized |
0.2% |
P501-600 |
600A |
720A |
1A |
600:1 |
customized |
0.2% |
P501-800 |
800A |
960A |
1A |
800:1 |
customized |
0.2% |
P501-1000 |
1000A |
1200A |
1A |
1000:1 |
customized |
0.1% |
P502-500 |
500A |
600A |
500mA |
1000:1 |
customized |
0.1% |
P502-1000 |
1000A |
1200A |
500mA |
2000:1 |
customized |
0.1% |
P503-800 |
800A |
960A |
400mA |
2000:1 |
customized |
0.1% |
P503-1000 |
1000A |
1200A |
400mA |
2500:1 |
customized |
0.1% |
P504-500 |
500A |
600A |
250mA |
2000:1 |
customized |
0.1% |
P504-1000 |
1000A |
1200A |
250mA |
4000:1 |
customized |
0.1% |
|
|
|
|
|
|
|
Model |
Rate Current |
Max Current |
Secondary Voltage |
Coil Ratio |
Burden Resistance |
Accuracy |
P50V1-1000 |
1000A |
1200A |
1V |
1000:1 |
customized |
0.1% |
P50V2-1000 |
1000A |
1200A |
2V |
1000:1 |
customized |
0.1% |
P50V4-1000 |
1000A |
1200A |
4V |
1000:1 |
customized |
0.1% |
P50V5-1000 |
1000A |
1200A |
5V |
1000:1 |
customized |
0.1% |
P50V10-1000 |
1000A |
1200A |
10V |
1000:1 |
customized |
0.1% |
P50V1-500 |
500A |
600A |
1V |
1000:1 |
customized |
0.2% |
P50V2-500 |
500A |
600A |
2V |
1000:1 |
customized |
0.2% |
P50V4-500 |
500A |
600A |
4V |
1000:1 |
customized |
0.2% |
P50V5-500 |
500A |
600A |
5V |
1000:1 |
customized |
0.2% |
P50V10-500 |
500A |
600A |
10V |
1000:1 |
customized |
0.2% |