IEC61850 Conformance Testing System with CE, ISO9001 Approved

Product Details
Customization: Available
Task: Program
Structure: Combination
Gold Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
>2000 square meters
  • IEC61850 Conformance Testing System with CE, ISO9001 Approved
  • IEC61850 Conformance Testing System with CE, ISO9001 Approved
  • IEC61850 Conformance Testing System with CE, ISO9001 Approved
  • IEC61850 Conformance Testing System with CE, ISO9001 Approved
  • IEC61850 Conformance Testing System with CE, ISO9001 Approved
  • IEC61850 Conformance Testing System with CE, ISO9001 Approved
Find Similar Products

Basic Info.

Model NO.
GF4600
Signal
Continuous
Function
Automatic Control
Certification
ISO: 9001, CE
Condition
New
Customized
Customized
Material
No
Description
IEC61850 Comformance Testing System
Application
Intelligent Power Grid Intelligent Substation
Standards
IEC61850
Strength
Easy to Operation
National Standard
Dl/T860
Transport Package
Standard Export Carton
Specification
CE, ISO9001: 2008, IEC
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
50 Set for One Month

Product Description

GF4600 - IEC61850 conformance testing system is in the electric power system in intelligent power grid, intelligent substation test to research and development of test tool. Conform to the international IEC61850 and national standard DL/T860 technical requirements. GF4600-IEC61850 conformance testing system uses friendly interactive graphical interface, easy to use flexible, which is based on the power system to engage in scientific research, measurement, automation, protection professional engineer development tools, users need to grasp the concept of a few IEC61850, he can use the test tool. The test system can fully comparable with the Netherlands KEMA IEC61850 conformance testing software, and better compatibility.
IEC61850 Conformance Testing System with CE, ISO9001 Approved
IEC61850 Conformance Testing System with CE, ISO9001 Approved
IEC61850 Conformance Testing System with CE, ISO9001 Approved
> IEC 61850 Protocol Analyzer
> IEC 61850 Client Simulator
> IEC 61850 GOOSE Simulator
> IEC 61850 SCL Checker
> IEC 61850 SCL Multi IED Simulator
> IEC 61850 MU Test
> IEC 61850 IED Test
> IEC 61850 Double Network Redundancy Test
Functions
Ø         IEC61850 server test: simulation 61850 client, test intelligent electronic equipment IED (measurement and control unit, protection unit, etc.),
Ø         Support " Plug AndTest " function: support at the same time testing many sets of IED shrapnel in their ability to support the measured IED shrapnel "Plug namely test (Plug AndTest)" function.
Ø         Model configuration files detection: support equipment model static conformance testing, support model dynamic test, support comprehensive application service model test.
Ø         IEC61850 client test: simulation 61850 server, test intelligent substation background system and far motivation system.
Ø         Merge units test: simulation send/receive sampling value message IEC61850-9-1 or IEC61850-9-2 (LE).
Ø         Intelligent units device test: simulation send/receive sampling value message IEC61850 - GOOSE.
Ø         Double network redundancy test: test the Lord, for the network switching function.
Ø         Time synchronization test: test 61850 time synchronization SNTP service function.
Features
1.       Simulation 61850 client can request IEC61850 directory service, the realization, speaking, reading and writing, to create, delete data set service, receiving reports, log, control, protection fixed value, setting changeover, document service. The client support multiple server, support twin wire hot standby.
2.       Automatic polling test multiple IED, detection communication status, remote measure, remote communication, SOE, remote control, remote regulating function;
3.       Detect the network switching situation data is lost;
4.       Automatic scanning inspection directory services, data set services, report service, log, protection fixed value, documents, GOOSE control block, sampling value SMV control block;
5.       Operation steps to be automatic record in a file, automatic analysis of test results, and gives the information prompt,
6.       Support control block report, log control block, protection fixed value control block, GOOSE control block operation;
7.       Analytic report, test report of switching;
8.       Simulation 61850 server, support IEC61850 directory service, support, speaking, reading and writing, to create, delete data set services, send a report, log, control, protection fixed value, setting changeover, document service. The server support multiple client.
9.       The report function support caching report (BRCB) and the cache report (URCB).
10.   According to the intelligent equipment IED shrapnel communications services, to resolve the intelligent equipment logical device model, each logical interface model, all of the telesignalisation, telecontrol and telesignalisation etc data model.
IEC61850 Conformance Testing System with CE, ISO9001 Approved
IEC61850 Conformance Testing System with CE, ISO9001 Approved
IEC61850 Conformance Testing System with CE, ISO9001 Approved

Intelligent substation has widely adopted IEC 61850 standard communication, the standardization of information model is the basis for intelligent substation equipment (or system) to achieve IEC 61850 communication. This module can test if the information model meet the requirements of DL/T860 standard, national network and related model specifications. It can test and control unit model, protection unit model, econometric model, condition monitoring model. It is selectable to test according to IEC61850-6 SCL grammatical rules, IEC61850-7 logic nodes and common data, the national network model standards and custom models.
According to 61850-10 rules, this software is to confirm whether the tested product meet the standards on consistency requirements.
 

Simulated client IEC61850, testing intelligent electronic devices IED (the control unit, the protection unit etc.). Testing the IED directory tree, IED associated equipment, servers, logical devices, logical nodes and data, data sets, replacing, reporting, setting the group control, recording, controlling and other functions.
 

Simulated client IEC61850, automatic testing intelligent electronic devices IED (the control unit, the protection unit etc.), according to predetermined test (IEC61850-10), exporting the test results to a variety of file formats (word, pdf, html, xml).
Can automated test based on ICD / CID files.
 

Simulated server IEC61850, testing back-office systems and far motivation systems of intelligent substation. According IED and ICD files, simulating MMS server to achieve the directory tree, logical devices, logical nodes, data reading and writing, data sets, valuation, reporting, replacing and other functions.
 

Simulation issue event message IEC61850-GOOSE, testing if the operation of the IED is correct. You can configure Priority, Dest MAC Address, VLanID, Source MAC Address, APPID, timetoLive, gocbRef, datSet, goID, test, confRev, numEntries, GOOSE data formats and other parameters.
 

Simulation receive event message IEC61850-GOOSE, testing if the issued GOOSE of the digital device IED is correct.
Recognition IEC61850-GOOSE message, setting the message format, displaying Goose in graphical data
 

Simulation issue sampled value message IEC61850-9-1 or IEC61850-9-2 (LE), testing the digital device IED. You can configure Priority, Dest MAC Address, VLanID, Source MAC Address, APPID, datSet, svID, confRev, SMV data formats and other parameters.
 

Simulation receive sampled value message IEC61850-9-1 or IEC61850-9-2 (LE), testing if the issued message of digital merger unit is correct.
Recognition IEC61850-9-2 (LE) message, setting the message format, displaying SMV in graphical data
 

Software test if the CID / ICD files and intelligent substation IED device implementation model is consistent, simple and flexible, the features are following:
1) Use the XML parser reads and parses the CID / ICD files and extract model information;
2) Import the IP address of MMS server at the interface, use the MMS client mode to communicate with the tested IED device, read layers of the model information of the tested IED device online by ACSI model service
3) Compared the information from 1) and 2), you can check if the CID / ICD files and intelligent substation IED device implementation model is consistent.
 

Monitoring network interfaces, in-depth analysis of network protocol message such as MMS, goose, SMV etc., showing the real MMS interaction.
Monitoring substation network, capturing and analyzing IEC 61850 information, and can be used for acceptance testing, interoperability testing, conformance testing, error logs and network performance monitoring, support IEC 61850 products development.
 

Testing 61850 time synchronous with SNTP service.
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More