30A576V Portable Single Phase Reference Energy Meter with 100A Clamp on CT

Product Details
Customization: Available
After-sales Service: 24 Hour Service
Warranty: 3 Years
Still deciding? Get samples of US$ 12000/Set
Request Sample
Gold Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
>2000 square meters
  • 30A576V Portable Single Phase Reference Energy Meter with 100A Clamp on CT
  • 30A576V Portable Single Phase Reference Energy Meter with 100A Clamp on CT
  • 30A576V Portable Single Phase Reference Energy Meter with 100A Clamp on CT
  • 30A576V Portable Single Phase Reference Energy Meter with 100A Clamp on CT
  • 30A576V Portable Single Phase Reference Energy Meter with 100A Clamp on CT
  • 30A576V Portable Single Phase Reference Energy Meter with 100A Clamp on CT
Find Similar Products

Basic Info.

Model NO.
GF111B 0.04%
Power
Electricity
Certification
FDA, CE, IAF, CCC, Ilac.Mra
Voltage Output
380V
Current Output
40A
LCD Display
With LCD Display
Customized
Non-Customized
Hot Sales
Portable Single Phase Reference Meter
Communication Ports
RS232
with 100A Clamp on CT
Yes
Frequency
40-70Hz
Accuracy
0.05%
Keypad
21 Keypads
LCD
7 Inch Touch Color
Weight
2kg
Harmonic Measurement
2-51st
Applications
Energy Meter Accuracy Test
Transport Package
Standard Export Carton
Specification
GF111B 0.05% 30A/576V
Trademark
GFUVE
Origin
Beijing, China
HS Code
90308490
Production Capacity
20000/Month

Product Description

GF111BSINGLE PHASE REFERENCE ENERGY METER WITH 100A CLAMP ON CT

GF111B single phase reference energy meter with 100a clamp on ct is the latest product launched by our company after extensive visits to users and drawing on the advantages of similar products at domestic and abroad. The measurement part of the product adopts high-speed A/D converter and DSP for digital processing technology, which greatly improves the accuracy and stability of measurement. The central processing part adopts 32-bit ARM embedded technology, which makes the instrument have novel interface, rich functions, clear and simple operation and stable performance. it has not only advantages of light weight, portable structure, high precision, high performance, powerful function, original interface, ease-to-use, but also work stability. It can measure U, I, P, Q, S, E, frequency, power factor, phase angle, harmonics etc. Accuracy class: 0.04.
The GF111B portable single phase reference meter can be widely used in fields of electric energy measuring, electric energy laboratories and other relevant industry, not only in laboratories but also at the industrial field.
30A576V Portable Single Phase Reference Energy Meter with 100A Clamp on CT

30A576V Portable Single Phase Reference Energy Meter with 100A Clamp on CT
APPLICATION

Metrological service center;

Laboratories of power utilities;

Electricity meter manufacturers;

Electricity power bureau & power company;

National Metrology and testing department;

Electrical Department of industrial and mining enterprises;

AMI design center;

Electrical laboratory;

Energy meter R & D;

Watt-hour meter factory;

FEATURES

Phase angle precision less than 0.02°;

Multi range, automatic range switching;

High stability 0.005%/min, high reliability;

Vector diagram function;

Waveform display function;

7 inch TFT color LCD display;

Energy register testing function;

Measuring 2nd~51st harmonics;

High accuracy class up to 0.04%;

0-576V, 1mA-120A, 40-70.000Hz;

Metal structure, strong and reliable;

Suit for testing in the lab and on site;

Current measurement with direct and clamp on ct;

Programmable pulse constant output up to 750000;

5A, 10A, 20A, 100A, 200A, 300A, 500A, 1000A, 3000A, 5000A optional

PARAMETERS

Electrical parameters
Accuracy class 0.04%, 0.05%, 0.1%
Power supply 45-450V AC, 50/60Hz
Power consumption 10VA
Voltage measurement
Range 0-576.000V
Error ±0.02% (40V-560V)
±0.05% (5V-40V)
Harmonic 2nd- 51st
Current measurement(direct)t
Range (direct connection) 1mA-30.000A
Error (direct connection) ±0.02% (25mA-30A)
±0.04% (1mA-25mA)
Harmonic 2nd- 51st
Clamp on ct (indirect)
Range (Standard) 1mA-120.000A
Error (Standard) ±0.04% (100mA-120A)
±0.1% (1mA-100mA)
Harmonic 2nd- 51st
Clamp on ct optional 5A, 10A, 20A, 100A, 200A, 300A, 500A, 1000A, 3000A, 5000A
Power measurement error
Active power ±0.04% (0.01A-30A)
±0.1% (0.001A-0.01A)
Reactive power ±0.1% (0.001A-30A)
Energy measurement error
Active energy ±0.04% (0.01A-30A)
±0.1% (0.001A-0.01A)
Reactive energy ±0.1% (0.001A-30A)
Phase angle
Range 0°-360.000°
Resolution 0.005°
Error ±0.02°
Power factor
Range -1.00000-0-1.00000
Resolution 0.0005
Error 0.0001
Frequency
Range 40.0000-70.0000Hz
Resolution 0.0005
Error ±0.001
Pulse output
Output channel 1
Energy constant 1-9999999
Pulse ratio 1:1
Output level 5V
Output rated frequency 60KHz, max 86.4KHz
Pulse input
Input channel 1
Input level 5-24V or 3-12V
Input frequency Max. 2MHz
Function
LCD Display 7 inch 800x480 pixel touch TFT
Vector diagram Yes
Waveform Yes
Key 18PCS
Energy accumulation Yes
Self-calibration Yes
Data storage Yes
PC software Optional
Communication port RS232 & USB
Standard
Standard IEC 62053-21,22, 23; IEC 60736; ANSI C12.20-2002;
JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019;
DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016; GB/T 33708-2017
Safety
Isolation protection IEC 61010-1:2001
Measurement Category 300 V CAT III, 600 V CAT II
Degree of protection IP65
Declaration of conformity CE & CNAS certified
Mechanical parameters
Dimensions (W×D×H) (mm) 365 x 269 x 151
Weight (kg) 3
Environmental conditions
Ambient temperature 0°C to 40°C
Storage temperature -20°C to +65°C
Relative humidity 10%-85%
Temperature coefficient ≤0.0005% /ºC
Influence of external fields ≤0.05 %/mT