• Test-330b Three Phase Secondary Current Injection Test Set
  • Test-330b Three Phase Secondary Current Injection Test Set
  • Test-330b Three Phase Secondary Current Injection Test Set
  • Test-330b Three Phase Secondary Current Injection Test Set
  • Test-330b Three Phase Secondary Current Injection Test Set
  • Test-330b Three Phase Secondary Current Injection Test Set

Test-330b Three Phase Secondary Current Injection Test Set

Theory: Electromagnetic Relay
Usage: Three Phase Secondary Current Injection Test Set
Phase: 3
Electricity Type: Vacuum
Load: Medium Power Relay
Protective Characteristics: Enclosed Rlay
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
TEST-330B
Action Principle
Electromagnetic Type
Size
Subminiature
Type
Electric Parameter Relay
Keyword
Three Phase Secondary Current Injection Test Set
Model
Secondary Current Injection Test Set
Test-330b
Current Injection Test Set
Line Voltage Output (Effective Value)
0-260V
Idle Contact
1-20mA, 24V (DC)
Output Frequency
0-1050Hz
Superposed Harmonic Wave
 0-21times
Weight (Kg)
16.6
Transport Package
Standard Export Wooden Box
Specification
360x195x375
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
1000pieces/Month

Product Description

TEST-330B Three Phase Secondary current Injection Test Set
Test-330b Three Phase Secondary Current Injection Test Set
Test-330b Three Phase Secondary Current Injection Test Set
Test-330b Three Phase Secondary Current Injection Test Set


The Test-330B three phase secondary current injection test set is the first choice for applications requiring very high accuracy more than 0.1%. This unit is not only an excellent test set for protection devices of all kinds but also a universal calibrator. It can as a ac or dc current source and voltage.
Its unique accuracy and reliability make the Test-330B ideal for protection and measurement equipment manufacturers for research and development, production and electric power company type testing.
Features
Embedded host machine equipped with Complex Programmable Logic Device (CPLD)
Eight-path synchronous D/A output in a single machine
High-accuracy linear power amplifier
Host machine integrated single cabinet structure with big LCD screen and complete interface has obtained appearance patent
Intelligent self-protection function
Plentiful Binary and powerful software function
Easily complete the ABB, Siemens, AREVA, GE, SEL, VAMP, Toshiba, NR, Sifang and other foreign manufacturers of protective device test
Synchronous output of five-phase voltage and three-phase current, Max AC current output is 90A, Max AC voltage output is 260V
Overview
3 phase current output
5 phase voltage output
8 binary input, 4 binary output
Accuracy more than 0.1%
Test item
U/I test
DC test
Impedance characteristics
Power direction test
I-T test
Differential relay
Harmonic test
Differential protection
Distance protection
Zero sequence protection
Setting group test
State sequence
Synchronization test
Special test
Oscillation test
Metering instrument
Hardware checkout
Low Voltage protection
Fault Waveform Reproduction
Parameters
Electrical parameters
Power voltage AC220V±10% or AC110V±10%, 50/60Hz±10%
Time measurement 0.1ms-999999.999s
AC current output
Phase current output (effective value) 3 x 0-30A
Maximum power output 260VA/phase
Maximum parallel current output (effective value) 0-90A
Long-term allowable working value of phase current
(effective value)
>10A
Allowable working time of maximum current  >11s
Accuracy class  <±0.1%
AC voltage output
Phase voltage output (effective value) 5 x 0-130V
Line voltage output (effective value) 0-260V
Maximum power output 70VA/phase
Accuracy class  <±0.1%
DC current output
Output range -10 to 10A or 3 x 0 to ±10A
Maximum power output 200VA
Accuracy class  <±0.1%
DC voltage output
Output range  0-300V or 5 x 0 to ±130V
Maximum output power 130VA
Accuracy class  <±0.1%
Binary input
Idle contact 1-20mA, 24V (DC)
Electric potential contact 250V/0.5A (DC)
Binary output
Idle contact  250V/0.5A (DC)
Rated output
Frequency error <±0.01Hz
Phase error    <±0.1%
Waveform distortion <±0.3% (fundamental wave)
Time error  <40µs
Output frequency  0-1050Hz
Superposed harmonic wave  0-21times
Mechanical parameters
Dimensions (L×W×H) (mm) 360x195x375
Weight (kg) 16.6
Environmental conditions
Use range 0°C to 45°C