• CT/PT Calibration Equipment Gfuve Transformer Calibrator CT PT Analyzer
  • CT/PT Calibration Equipment Gfuve Transformer Calibrator CT PT Analyzer
  • CT/PT Calibration Equipment Gfuve Transformer Calibrator CT PT Analyzer
  • CT/PT Calibration Equipment Gfuve Transformer Calibrator CT PT Analyzer
  • CT/PT Calibration Equipment Gfuve Transformer Calibrator CT PT Analyzer
  • CT/PT Calibration Equipment Gfuve Transformer Calibrator CT PT Analyzer

CT/PT Calibration Equipment Gfuve Transformer Calibrator CT PT Analyzer

Application: Electromagnetic Instrument
Power: Electricity
Certification: CE, IAF, CCC
Voltage Output: 0-150V
Current Output: 0-15A
LCD Display: With LCD Display
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF106
Customized
Customized
Power Supply
AC220V±10%, 50/60Hz
Standby Time with Battery
>5 Hours
Output
0~150vrms, 5arms(15apeak
Burden Measurement
0~50
Size
380 Mm X 180 Mm X 240 Mm
Weight
8kg
Transport Package
Standard Export Carton
Specification
CE, ISO9001: 2008, IEC
Trademark
GFUVE
Origin
Beijing China
Production Capacity
200units/Month

Product Description

Application of CT/PT calibration equipment GFUVE Transformer Calibrator Ct PT Analyzer,with excellent working performance

It is mainly used to detect on phase error, ratio error, burden and admittance test of CT&PT. In addition, it supports data save and site printing, this can not only omit a lot of troublesome work such as manual voltage regulating, manual record and curve tracing, but also dump testing data through USB interface with USB disk.

Reference Standard
GB 1207-2006, GB 1208-2006 (IEC 60044-1), GB16847-1997 (IEC 60044-6), IEEE C57.13-1993

Main Features

1. With single phase input voltage of AC220V and battery power.
2. It can be used to detect burden, admittance, ratio error and phase error.
3. The wiring method is very simple, only 8 test terminals are needed to finish all testing items.
4. Rotation controller, 320× 240(4.7 inch)graphical liquid crystal display.
5. It carries with it thermal printer, so it can print test results on site.
6. It can save 1000 groups of test results, which will not loss after power down.
7. USB communication interface for USB disk.
8. Small in size, light weight, simple on-site operation.

Main functions
1. Burden
2. Admittance
3. Phase Error
4. Ratio Error
 
Items Parameter
Power supply AC220V±10% , 50/60Hz
Standby time with battery >5 Hours
Equipment output 0~150Vrms,5Arms(15Apeak )
Voltage measurement accuracy ±0.1%
Burden measurement range 0~50
accuracy 0.2%
Admittance range 0~60mS
accuracy 0.2%
Two times the actual  Load measurement range 0~300VA
accuracy 1%±0.1VA
Phase error measurement accuracy ±3min
resolution 0.3min
CT phase ratio error measurement range 5:1~15000:1
accuracy
 
0.05%
PT phase ratio error measurement range 5:1~15000:1
accuracy ±0.05%
Work environment Temperature:-10 ~ 40 , humidity:≤ 85% or altitude ≤1000 m
Size 380 mm x 180 mm x 240 mm(L×W×H),
Weight 8kg
CT/PT Calibration Equipment Gfuve Transformer Calibrator CT PT Analyzer
CT/PT Calibration Equipment Gfuve Transformer Calibrator CT PT Analyzer

http://guangfuhui.en.made-in-china.com

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now