Customization: | Available |
---|---|
Application: | Mechanical Instrument, Time Frequency Instrument, Electromagnetic Instrument, Power Source for CT |
Power: | Electricity |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Electrical parameters | |
---|---|
Accuracy class | 0.05%, 0.1% |
Power supply | Single phase AC 85-265V, 50/60 Hz |
AC Voltage output | |
Range | 57.7V / 100 V / 220V / 380V, Switch automatically (max 500V) |
Adjustment resolution | 0.01%, 0.1%, 1%, 10%, |
Accuracy | 0.05% RG |
Stability | Better than 0.01% RG/1min |
Distortion degree | Better than 0.1% (not capacitive load) |
Load capacity | 40VA |
Full load regulation rate | Less than 0.01% RG |
Full load regulation time | Less than 1ms |
Temperature drift | 8 PPM/°C |
Long-term stability | 60 PPM/year |
AC Current output | |
Range | 0.1A / 0.25A / 0.5A / 1A / 5A / 10A / 20A / 50A / 100A, Switch automatically |
Adjustment resolution | 0.01%, 0.1%, 1%, 10%, |
Accuracy | 0.05% RG |
Stability | Better than 0.01% RG/1min |
Distortion degree | Better than 0.1% (not capacitive load) |
Load capacity | 40VA |
Full load regulation rate | Less than 0.01% RG |
Full load regulation time | Less than 1mS |
Temperature drift | 8 PPM/°C |
Long-term stability | 60 PPM/year |
Power output | |
Active power accuracy | 0.05% or 0.1% |
Reactive power accuracy | 0.1% or 0.2% |
Stability | Better than 0.01% RG/1min |
Phase | |
Range | 0°-359.99° |
Adjustment resolution | 0.01°, 0.1°, 1°, 10° |
Accuracy | 0.03° |
Frequency | |
Range | 40-65 Hz |
Adjustment resolution | 0.001 Hz, 0.01 Hz, 0.1 Hz, 1Hz |
Accuracy | 0.002 Hz |
Temperature drift | 0.5 PPM/°C |
Long-term stability | 4 PPM/year |
Harmonic | |
Harmonic times | 2nd-63th |
Adjustment resolution | 0.1% (Compared with fundamental wave) |
Harmonic content (Compared with fundamental wave) | |
Voltage | ≤40% |
Current | ≤40% |
Phase | 0°-360° |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 420x320x155 |
Weight (kg) | 12 |
Environmental conditions | |
Operating temperature | 0°C to 40°C |
Storage conditions | -30°C to 60°C |
Relative humidity | ≤85% |