Electrical parameters |
|||||||
---|---|---|---|---|---|---|---|
Model | FQ-RCT01-55 | FQ-RCT01-80 | FQ-RCT01-105 | FQ-RCTA01-55 | FQ-RCTA01-80 | FQ-RCTA01-105 | |
10A~10kA | Maximum input current | 10A~6000A | |||||
Current Range | 25Hz~20kHz | 45Hz~600Hz | |||||
Output voltage | Rated current | 500A | 1000A | 2000A | 250A, 500A, 800A, 1000A | 1000A, 1500A, 2000A, 2500A | 1000A, 2000A, 2500A, 3000A |
50Hz | 50mV AC | 100mV AC | 200mV AC | ||||
333mV 1mV/A |
|||||||
Max output | / | 3.0V AC max | |||||
Accuracy | <1% @25°C (45-65Hz) | <1% @25°C (45-65Hz) | |||||
Phase error | <60' @25°C (45-65Hz) | <60' @25°C (45-65Hz) | |||||
Output sensitivity | ±2% Max (No Calibration) ±0.5% @25°C (With Calibration) |
1% | |||||
Linearity error | ±0.2% (10%-100%I1n) | ±0.2% | |||||
Position sensitivity | ±2%(45-65Hz) | ±2% | |||||
External influence | ±2% Max | ±1.5% Max | |||||
Power supply | / | 10-30VDC,30mA Max. |