High Quality Clamp Type Multimeter Calibrator for Electrical Calibration

Product Details
Customization: Available
Application: Electromagnetic Instrument
Power: Electricity
Gold Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
>2000 square meters
  • High Quality Clamp Type Multimeter Calibrator for Electrical Calibration
  • High Quality Clamp Type Multimeter Calibrator for Electrical Calibration
  • High Quality Clamp Type Multimeter Calibrator for Electrical Calibration
  • High Quality Clamp Type Multimeter Calibrator for Electrical Calibration
  • High Quality Clamp Type Multimeter Calibrator for Electrical Calibration
  • High Quality Clamp Type Multimeter Calibrator for Electrical Calibration
Find Similar Products

Basic Info.

Model NO.
GF6018A
Voltage Output
0-1200V AC/DC
Current Output
0-24A AC/DC
LCD Display
With LCD Display
Customized
Customized
Accuracy
0.05%
Usage
Multimeter Calibrator
Frequency
45-65Hz
Harmonics
2-31 Th
Transport Package
Standard Export Carton
Specification
CE. ISO9001: 2008, standard IEC
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
200PCS/Month

Product Description

GF6018A High Quality Clamp Type Multimeter Calibrator for Electrical Calibration
High Quality Clamp Type Multimeter Calibrator for Electrical Calibration
High Quality Clamp Type Multimeter Calibrator for Electrical Calibration
High Quality Clamp Type Multimeter Calibrator for Electrical Calibration
The equipment is compliance with national verification regulation: JJG124-2005 "Ammeter, voltmeter, power meter and resistance meter verification rules" and related national standards. 0.05 single-phase AC/DC standard source, can verify magnitude 0.2 and the following AC/DC voltmeter, ammeter, frequency meter, resistance meter. The source signals by using DSP and 16-bit high-speed analog-to-digital converters of controllable sine wave, the distorted wave signal source.The equipment comes with RS-232 interface, can be connected with PC to a semi-automatic verification system. It has precise interface and multi-functions including verification, storage and query.The equipment adopts color LCD screen, chart character display is clear, with high precision, stable and reliable, convenient operation and flexible characteristics.

FEATURES
It can be semi-automatic or manual inspection of analog multi meter, clamp type current meter, all kinds of electric meter, (voltmeter, ammeter, frequency meters, resistance meter) basic error
The equipment can be generated with 2-31 harmonic wave, harmonic number, order, amplitude and harmonic phase of fundamental wave can be programmed
Power amplifier working frequency range is 40Hz-1KHZ, has a good linear. Current amplifier is constant current source; voltage amplifier is constant voltage source. Because of light weight, this device is more suitable for field use
With RS-232 interface, this device is controlled by PC through the PC software (optional), can be automatic or manual inspection, and the results are processing and management
Has a non-volatile memory, it can store 500 pieces of the raw data of tested meter, for access and upload
 
PARAMETERS

Electrical parameters
Power supply Single phase AC 220V±10% or 110V±10%, 50/60HzAC
AC Voltage output
range 200mV, 400mV, 2000mV, 4000mV, 
20V, 100V, 200V, 500V, 1000V
Range 20V-1000V Accuracy ±(0.03%RD+0.02%FS)
Stability ≤0.01% FS /60s
Range 200mV-4000mV Accuracy ±(0.3%RD+0.2%FS)
Stability ≤0.04% FS /60s
Load capacity 20VA
Waveform distortion ≤0.3%
Adjustable Range 0-120% FS (1000V not included)
Fineness 5×10-5
AC Current Output
Range 2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A
Range 0.2A-20A  Accuracy ±(0.03%RD+0.02%FS)
Stability ≤0.01% FS /60s
Range 2mA-40mA   Accuracy ±(0.3%RD+0.2%FS)
Stability ≤0.04% FS /60s
Load capacity 20VA
Waveform distortion ≤0.3%
Adjustable Range 0-120% FS
Fineness 5×10-5
Frequency Output
Range 45-65Hz
Fineness 0.001Hz
Accuracy 0.01Hz
Harmonic Wave
Times 2-31
Extent 0-20%
Each harmonic phase fineness  0.01·N (N is  harmonic order)
DC voltage output
Range 200mV, 400mV, 2000mV, 4000mV, 
20V, 40V, 100V, 200V, 400V, 1000V
Load capacity 20W
Adjustable range 0-110% FS (1000V not included)
Adjustable fineness 5×10-5
Stability ≤0.01% FS /60s (peak-peak value)
Accuracy ±(0.03%RD+0.02%FS)
Ripple wave ≤1% FS
DC current output
Range 20uA, 40uA, 200uA, 400uA, 2mA, 4mA, 
20mA, 40mA, 0.2A, 1A, 2.5A, 5A, 10A, 20A
Load capacity 20W
Adjustable Range 0-110% FS (1000V not included)
Adjustable Fineness 5×10-5
Stability ≤0.01% FS /60s (peak-peak value)
Accuracy ±(0.06%RD+0.04%FS)
Ripple wave ≤1% FS
Resistance box
Range 0-200Ω, 200-400Ω, 0-2kΩ, 2kΩ-4kΩ, 0-20kΩ, 20kΩ-40kΩ, 
0-200kΩ, 200kΩ-400kΩ, 0-2MΩ, 2MΩ-4MΩ
Fineness 0.02%
Range 0-2kΩ, 0-20kΩ, 0-200kΩ 
Range 0-2kΩ  Adjustable Range 0-100%FS
Accuracy ±(0.12%RD+0.08%FS)
Range 0-200Ω,0-2MΩ Adjustable Range 0-100% FS
Accuracy ±(0.3%RD+0.2%FS)
Range 2kΩ-4kΩ, 20kΩ-40kΩ, 200kΩ-400kΩ
Range 2kΩ-4kΩ Adjustable Range 5%-100%FS
Accuracy ±(0.12%RD+0.08%FS)
Range  200-400Ω, 
2MΩ-4MΩ
Adjustable Range 5%-100% FS
Accuracy ±(0.3%RD+0.2%FS)
Clamp meter range
200A Accuracy ±0.2%
600A Accuracy ±0.5%
1000A Accuracy ±1%
Dot frequency square wave output
Range 1kHz, 5kHz, 10kHz, 50kHz, 100kHz, 200kHz, 1000kHz
Square wave amplitude 4.5V
Setting accuracy 5×10-5
Mechanical parameters
Dimension (L×W×H) (mm) 440x360x160
Weight (kg) 12
Environmental conditions
Operating temperature 20°C±10°C
Relative humidity ≤85%RH