Application of Power Test instrument GF302C portable panel meter Calibrator with RS 232 interface, CE, ISO approved
It is suitable for power plant and substation work area of grid companies, make try department and the instrument classes, and national levels measuring and testing institutions, railway, petroleum, chemical industry and other large industrial and mining enterprises, scientific research units, etc.
Introduction
This device is according to nation verification regulation JJG124-2005 "ammeter, voltmeter, power meter and resistance meter calibration regulations and the relevant countries standard requirements and design three-phase 0.05 magnitude meter source integration calibration device. The core technology of the function of device with digital signal processor (DSP) and 16 high-speed digital converter composed of high precision work frequency communication terminal; The signal source of use is DSP and 16 high-speed digital-to-analog converters can control of the sine wave, distortion wave signal source; Equipment has high precision, stable and reliable, and convenient operation, flexible, and other characteristics; Electric power system is used for electrical measurement is the ideal equipment calibration.
Functions and Features
It can check all kinds of electric measurement of instrument, including: AC/DC voltmeter, AC/DC ammeter, frequency meter, phase angle meter, single/three-phase AC active power meter, single/three-phase AC reactive power meter, synchronous meter, etc.;
Built-in electric measurement of verification procedure and indicating meter, automatic or semi-automatic for verification, saving 1000 group check data;
It is as a voltage source, a current source and power source for high precision and high stability standard resource;
6.4 inch big screen color display;
It is calibrated in the software, not need to open the case, stable and reliable;
Having short circuit, current output terminal, output voltage open protection and power amplifier overheating protection function;
To have automatically failure detection function, shows fault part, the convenience users check line;
With RS232, and computer connection for data management.
Specifications |
|
AC voltage output |
|
Range: |
50 V, 100 V, 200 V, 400 V, 800 V; |
Adjusting range: |
(0-120) % RG |
Adjust fineness: |
0.01% RG |
Accuracy: |
0.05% RG |
Stability: |
0.01% / 1 min |
Load capacity: |
25 VA |
Output distortion degree: |
≤ 0.3% or (linear load) |
AC current output |
|
Range: |
0.5A, 1A, 2.5A, 5A, 10A, 20A; |
Adjusting range: |
(0-120) % RG |
Adjust fineness: |
0.01% RG |
Accuracy: |
0.05% RG |
Stability: |
0.01% / 1 min |
Load capacity: |
25 VA |
Output distortion degree: |
≤ 0.3% or (linear load) |
AC power output |
|
Accuracy: |
0.05% RG |
Stability: |
0.01% / 1 min |
Frequency |
|
Frequency range: |
45.000 ~ 65.000 Hz |
Resolution: |
0.001 Hz |
Accuracy: |
0.01 Hz |
Power factor output |
|
Adjusting range: |
-1~0~1 |
Adjust fineness: |
0.0001 |
Accuracy: |
0.0005 |
Phase angle |
|
Scope: |
0.00 ° ~ 359.99 ° |
Resolution: |
0.01 ° |
Accuracy: |
0.05 ° |
Voltage/Current harmonic output |
2~31st |
DC voltage output |
|
Quantity limit: |
75 V, 150 V, 300 V, 500 V, 1000 V |
Adjusting range: |
(0-120) % RG |
Adjust fineness: |
0.005% RG |
Accuracy: |
0.05% RG |
Stability: |
0.01% / 1 min |
Load capacity: |
25 VA |
DC current output |
|
Quantity limit: |
0.5A, 1A, 2.5A, 5A, 10A, 20A |
Adjusting range: |
(0-120) % RG |
Adjust fineness: |
0.005% RG |
Accuracy: |
0.05% RG |
Stability: |
0.01% / 1 min |
Load capacity: |
25 VA |
Environmental conditions |
|
Working temperature: |
0 ~ 40° |
Relative humidity: |
≤ 85% |
Storage conditions: |
-30~ 60degrees |
Work power |
|
Single phase |
AC 220 V± 10%, Frequency 50/60 Hz |
Volume and Weight |
|
Size |
460 mm X 430 mm X 185 mm |
Weigth |
18Kg |