• Three Phase Volt-Ampere Meter
  • Three Phase Volt-Ampere Meter
  • Three Phase Volt-Ampere Meter
  • Three Phase Volt-Ampere Meter
  • Three Phase Volt-Ampere Meter
  • Three Phase Volt-Ampere Meter

Three Phase Volt-Ampere Meter

Brand: Gfuve
Customized: Customized
Certification: CE, ISO
Display: Digital
Stucture: Electromagnetic
Gf211b: Multifunction Double Clamp Digital Phase Meter
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF211
Accuracy Class
1%
Clamps
10A
AC Voltage
0~500V
Frequency
20~65Hz
Power Supply
3.7V Lithium Battery
Active Power Accuracy
1%
Weight
0.26kg
Transport Package
Standard Export Carton
Specification
CE
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
1000sets/Month

Product Description

Application
GF311 multi-function double clamp digital phase angle meter is a multi-functional portable instrument. It can measure not only alternating voltage (U), but also alternating current (I), frequency (F), active power (P), reactive power (Q), power factor (PF) and so on. Its important function is to measure phase angle between two voltages, between two current or between voltage and current. The current signal is obtained by the clamp current transformer without cutting off current wire. It can discern inductive circuit and capacitive circuit; Can directly read differential protection phase among every unit of CT; Can check connection of transformer; Measure two way voltage phase sequence; Can check whether the meter connection is right or not; Can evaluate the running speed of electric kWh meter. It has high resolution of current, so can be used as a leakage current meter. It is an ideal choice for electric power bureau, factories, mine, petroleum -chemistry enterprises, metallurgy factories and so on.
Three Phase Volt-Ampere Meter

Three Phase Volt-Ampere Meter
Three Phase Volt-Ampere MeterSpecifications
2.1 Scale
2.1. 1 Phase: 0~360°
2.1. 2 AC Voltage: 0~500V
2.1. 3 AC Current: 200mA / 2A / 10A
2.1. 4 Frequency: 20~65Hz
2.1. 5 Active power accuracy: 1%, resolution 0.01W
2.1. 6 Power factor: -1~0~1, resolution 0.001

2.2 Fundamental error (under standard operating environment)
2.2.1 Standard Condition
2.2. 2 Phase accuracy 1.0% FS
2.2.3 Voltage accuracy
2.2.4 Current accuracy
2.3 Input impedance:
2.3. 1 1MΩ When measure voltage
2.3. 2 input voltage impedance>120KΩ When measure phase
2.4 operation condition
2.5 additional error
2.5. 1 When measure phase angle, the voltage and the current are in the range of the operating conditions, the additional error is less than the fundamental error.
2.5. 2 When measure current, the error LED by wires away from center of clamps is less than the fundamental error.
2.6 Safety specification
2.6. 1 Resistance to voltage
The meter can resist 1000V (AC sinewave, 50Hz or 60 Hz) for 1 minute both between the meter circuit and the meter case; Between input joint U1 and U2 can resist 500V(AC sinewave, 50Hz or 60 Hz) for 1 minute.
2.6. 2 Insulation resistance
The resistance both between the meter circuit and the meter surface and between the terminals U1 and U2 is greater than 100MΩ .
2.7 Power supply 3.7V batteries.
2.8 Size and Weight: 185 mmX85mmX41mm 0.26Kg
Accessories
Scale Accuracy Resolution
200V 1.0FS 0.1V
500V 1.0FS 1V
  
 
Temperature Moisture Wave Form Frequency Wire Position Phase measurement
voltage current
23±5degrees <65% Sine wave Distortion ≤1% 50± 2Hz, 60± 2Hz center of clamp 100V± 25V 1A±0.2A

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now