• 400/5A 10va IP65 Outdoors Split Core CT Current Transformer
  • 400/5A 10va IP65 Outdoors Split Core CT Current Transformer
  • 400/5A 10va IP65 Outdoors Split Core CT Current Transformer
  • 400/5A 10va IP65 Outdoors Split Core CT Current Transformer
  • 400/5A 10va IP65 Outdoors Split Core CT Current Transformer
  • 400/5A 10va IP65 Outdoors Split Core CT Current Transformer

400/5A 10va IP65 Outdoors Split Core CT Current Transformer

Application: Electronic, Instrument, Position Sensor
Type: Current Transformer
Phase: Single
Operation Condition: Outdoor
Usage: Measurement
Winding Form: Single Layer & Tightly Wound Type
Samples:
US$ 150/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
LZCK-55
Insulating Medium
Epoxy Resin
Installation
Busbar Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Capacitive Type
Accuracy
0.5%, 0.5s, 1%
Standards
GB1208-2006;IEC 60044-1;Ntc 2205
Safety Factor Rating
< 10
Rated Frequency
50Hz or 60Hz
Environment
Outdoors or Indoors
Rated Secondary Current
5A or 1A
Secondary Winding Power Frequency Withst
3kv/1min
Types
Split Core Current Transformer
Ratio
100-1500A/5A
Output Signal
10m Cable
Transport Package
Standard Export Box
Specification
0.5% or 1%
Trademark
GFUVE
Origin
Beijing, China
HS Code
8504311000
Production Capacity
10000PCS/Month

Product Description

LZCK-55 400/5A 10VA IP65 Outdoors Split Core ct Current Transformer for 10KV power line
400/5A 10va IP65 Outdoors Split Core CT Current Transformer

400/5A 10va IP65 Outdoors Split Core CT Current Transformer
400/5A 10va IP65 Outdoors Split Core CT Current Transformer
LZCK series IP65 outdoors instrument split core current transformers applicable for AC power system 35kV and measurement of current of power supply equipment below 10KV, and microcomputer protection. This type of current transformer employs imported silican steel which with high permeability as magnetic material, have the characteristics of Small magnetic circuit loss and can be cut, its semicircular core and secondary windings employ high quality epoxy resin vacuum, casting in plastic-case which is flame retardance anti-moisture, stable performance, no maintenance.
Parameters
Technical parameters  
Standards IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13
Accuracy Class 0.5S, 0.5%, 1%, 3%
Range of primary rated current 100-1500A
Range of Rated load ≤10VA
Rated frequency 50/60Hz
Rated secondary current 5A or 1A
Rated short-time thermal current 40kA, 1S
Rated continuous thermal current 150%I1n
Secondary winding power frequency withstand voltage 3kV, 1min
Safety Factor Rating (FS) <10
Output signal 1A, 5A, 333mV, 1V or 5V(customized)
Cable length 2.5m, 5m, 10m(customized)
Flame retardant ABS plastic shell inside, jaw waterproof apron.
Mechanical parameters  
Aperture (mm) Φ55
Dimensions (W×D×H) (mm) 180×138×52
Weight (kg) 2
Working conditions  
Operating temperature -35°C to +65°C, average  not exceeding +40°C
Storage temperature -40°C to +70°C
Ingress Protection IP65
Environment outdoors or indoors
The Height of above sea level 0- 3000m
Conditions No existence of severely begrimed, erosive and radioactive gas in the air. Continuous working under the rated current is allowed.

Selection Type
Type LZCK-55(2.5m cable)
Purpose Measuring current transformer
Ratio Accuracy class and rated load(VA)
I1/I2 0.5S 0.5 1 3
100/5     1.5 2.5
150/5     1.5 2.5
200/5 2.5 2.5 2.5 3
250/5 2.5 2.5 2.5 3
300/5 2.5 2.5 2.5 5
400/5 5 5 5 5
500/5 5 5 5 5
600/5 5 5 5 5
750/5 5 5 5 5
800/5 5 5 10 10
1000/5 10 10 10 10
1200/5 10 10 10 10
1250/5 10 10 10 10
1500/5 10 10 10 20

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.