Customization: | Available |
---|---|
Application: | Mechanical Instrument |
Power: | Electricity |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Electrical parameters | |||
---|---|---|---|
Accuracy class | 1%, 2% | ||
Power supply | Two 9V batteries | ||
Scale | |||
Phase | 0-360° | ||
AC Voltage | 500V | ||
AC Current | 200mA/2A/10A | ||
Fundamental error (under standard operating environment) | |||
Temperature | 23°C±5°C | ||
Moisture | <65% | ||
Wave form | Sine wave Distortion ≤1% | ||
Frequency | 50± 2Hz, 60± 2Hz | ||
Wire position | Center of clamp | ||
Phase measurement | Voltage: 100V± 25V Current: 1A±0.2A |
||
Phase accuracy | 1.0% FS | ||
Electrical parameters - continued | |||
Fundamental error (under standard operating environment) - contiued | |||
Voltage accuracy | |||
200V | 1.0FS, Resolution: 0.1V | ||
500V | 1.0FS, Resolution: 1V | ||
Voltage accuracy | |||
10A | 2.0FS, Resolution: 10mA | ||
2A | 2.0FS, Resolution: 1mA | ||
200mA | 2.0FS, Resolution: 0.1mA | ||
Input impedance | |||
When measure voltage | 1MΩ | ||
Input voltage impedance | >120KΩ when measure phase | ||
Phase measurement | |||
Voltage accuracy | 3V-500V | ||
Current range | 0.01A-10A | ||
Additional error | |||
Measure phase angle, the voltage and the current | Less than the fundamental error | ||
Measure current | The error led by wires away from center of clamps is less than the fundamental error | ||
Safety specification | |||
Resistance to voltage | The meter can resist 1000V (AC sine wave, 50Hz or 60 Hz) for 1 minute between the meter circuit and the meter case; Between input joint U1 and U2 can resist 500V (AC sine wave, 50Hz or 60 Hz) for 1 minute. | ||
Insulation resistance | The resistance both between the meter circuit and the meter surface and between the terminals U1 and U2 is greater than 100MΩ. | ||
Mechanical parameters | |||
Dimensions (W×D×H) (mm) | 185×167×35 | ||
Weight (kg) | 0.5 | ||
Environmental conditions | |||
Working temperature | 0°C±40°C | ||
Humidity | ≤80% | ||
Accessory | |||
Double clamp phase volt-ampere meter | 1 piece | ||
Clamps 10A | 2 pieces | ||
Clamp wire | 2 pieces | ||
Voltage wire | 2 pieces | ||
User's manual | 1 piece | ||
Accessory - continued | |||
Certification of quality | 1 piece | ||
Box | 1 piece |