High Quality Portable PT Voltage Transformer Tester

Product Details
Customization: Available
Application: Mechanical Instrument, Electromagnetic Instrument
Power: Electricity
Still deciding? Get samples of US$ 19898/Set
Request Sample
Gold Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
>2000 square meters
  • High Quality Portable PT Voltage Transformer Tester
  • High Quality Portable PT Voltage Transformer Tester
  • High Quality Portable PT Voltage Transformer Tester
  • High Quality Portable PT Voltage Transformer Tester
  • High Quality Portable PT Voltage Transformer Tester
Find Similar Products

Basic Info.

Model NO.
GF106
Voltage Output
220V
Current Output
5A
LCD Display
With LCD Display
Customized
Customized
Accuracy
0.05%, 0.1%
Excitation Output Voltage
0-220vrms
Excitation Output Current
0-5arms (20A Peak-Value)
Weight (Kg)  
10
Transport Package
Standard Export Wooden Box
Specification
410 x 250 x 300 
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
1000sets/Month

Product Description

CT/PT TESTER
High Quality Portable PT Voltage Transformer Tester
High Quality Portable PT Voltage Transformer Tester

GF106 Portable PT Voltage transformer tester is mainly used for field testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.

Features
Steady and transient state characteristic tests of various types of CT/PT
The use of advanced power technology, the test knee point reaches up to 40kV
No external other auxiliary equipment, stand-alone to complete all test items
CT test, easy to test, all the tests are using the same wire connection except the load test
It carries with thermal printer, so it can print test results on site
Parameters such as knee point current and voltage
Parameters such as 10% error curve, 5% error curve
The device can store 3000 groups of test data which would not be lost if the device is power off.
The data can be displayed and analyzed after the test, or transferred to PC through USB disk and produce a Word file report
Portability: weight < 12kg

FUNCTION
I. Current Transformer (CT) II. Voltage Transformer (PT)
1.  Magnetization curve 1.  Excitation characteristic test
2.  Transformation ratio test 2.  Transformation ratio test
3.  Polarity 3.  Polarity
4.  5% and 10% error curve 4.  Ratio error, phases
5.  Current Injecting 5.  Degauss
6.  Degauss 6.  Calculation of knee point value
7.  Ratio error, phases 7.  Actual secondary load (burden), test (burden)
8.  Automatic calculation of excitation knee point value 8.  Resistance test
9.  Actual secondary load test (burden) (load test)
10.  Resistance test
11.  Secondary winding time constant (Ts)
12.  Remanence coefficient (Kr)
13.  Transient dimensioning factor (Ktd)
14.  Peak instantaneous error (Er)
15.  Magnetizing inductance (LU)

Parameters
Electrical parameters
Accuracy 0.05%, 0.1%
Power supply AC 220V±10% or AC 110V±10%, 50/60Hz
Excitation output voltage 0-220Vrms
Excitation output current 0-5Arms (20A peak-value)
Automatic frequency variation range 0.1-60Hz
Equivalent excitation voltage ≤5000V
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary winding DC resistance measurement Range 0.1-300Ω
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary actual load measurement Range 5VA-1000VA
Accuracy ≤0.5% (0.2%RD+0.3%RG)±0.1VA
CT/PT phase error measurement Accuracy ±4min
Resolution 0.01min
CT ratio error measurement Range 1-30000
Accuracy ≤0.5%
PT ratio error measurement Range 1-10000
Accuracy ≤0.5%
Standards
Reference standards GB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2-2012
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2/3/4/6
Mechanical parameters
Overall dimension (L x W x H) (mm) 410 x 250 x 300 
Weight (kg)   ≤10 
Environmental conditions
Relative humidity    90RH%
Operating temperature -10°C to +40°C
Altitude ≤2000m

Main functions
The test items mainly include
Steady Transient
excitation characteristic secondary winding time constant (Ts)
transformation ratio remanence coefficient (Kr)
polarity transient dimensioning factor (Ktd)
ratio error peak instantaneous error (Er)
phases magnetizing inductance (LU)
5% and 10% error curves other parameters
resistance
secondary load
http://guangfuhui.en.made-in-china.com 
High Quality Portable PT Voltage Transformer Tester
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More