Electrical parameters |
|
---|---|
Accuracy class | 0.05%, 0.1% |
Power supply | Single phase AC 85V-265V, 50/60 Hz |
AC Voltage output | |
Range (U1, U2, U3 phase) | 57.7V/100V/220V/380V, switch automatically (max 420V) |
Adjustment resolution | 0.01%, 0.1%, 1%, 10%, |
Accuracy | 0.05% RG |
Stability | 0.005% RG/1min |
Distortion degree | better than 0.1% (not capacitive load) |
Load Capacity | 25VA |
Full load regulation rate | Less than 0.01% RG |
Full load regulation time | Less than 1mS |
Temperature drift | 8 PPM / °C |
Long-term stability | 60 PPM/year |
AC Current output | |
Range (I1, I2, I3 phase) | 0.1/0.25A/0.5A/1A/5A/10A/20A, switch automatically |
Adjustment resolution | 0.01%, 0.1%, 1%, 10%, |
Accuracy | 0.05% RG |
Stability | 0.005% RG/1min |
Distortion degree | better than 0.1% (not capacitive load) |
Load capacity | 25VA |
Full load regulation rate | Less than 0.01% RG |
Full load regulation time | Less than 1mS |
Temperature drift | 8 PPM/°C |
Long-term stability | 60 PPM/year |
Power output | |
Active power accuracy | 0.05% |
Reactive power accuracy | 0.1% |
Stability | 0.005% RG/1min |
Phase | |
Range | 0°-359.99° |
Adjustment resolution | 0.01°, 0.1°, 1°, 10° |
Accuracy | 0.03° |
Power factor | |
Adjusting range | -1 to 0 to +1 |
Resolution | 0.0001 |
Accuracy | 0.0005 |
Frequency | |
Range | 40-65Hz or 40-400Hz (option) |
Adjustment resolution | 0.001Hz, 0.01Hz, 0.1Hz, 1Hz |
Accuracy | 0.002Hz |
Temperature drift | 0.5PPM/°C |
Long-term stability | 4 PPM/year |
Harmonic | |
Harmonic times | 2-128 |
Adjustment resolution | 0.1% (compared with fundamental wave) |
Harmonic content (compared with fundamental wave) | |
Voltage | ≤40% |
Current | ≤40% |
Phase | 0°-360° |
Capacitive load capacity | |
0 - 280 V | 1uF |
280 - 420 V | 0.6uF |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 450x380x160 |
Weight (kg) | 18 |
Environmental conditions | |
Working temperature | 0°C to 40°C |
Storage conditions | -30°C to 60°C |
Relative humidity | ≤85% |
No. |
Accuracy | Voltage range | Current range | Weight | Remark |
---|---|---|---|---|---|
3030601 | 0.10% | 0-264V | 0-6A | 12KG | |
3030605 | 0.05% | 0-264V | 0-6A | 12KG | |
3031201 | 0.10% | 0-420V | 0-12A | 13.5KG | |
3031205 | 0.05% | 0-420V | 0-12A | 13.5KG | |
3032001 | 0.10% | 0-420V | 0-20A | 18KG | |
3032005 | 0.05% | 0-420V | 0-20A | 18KG | |
303H0601 | 0.10% | 0-300V | 0-6A | 15KG | XP system |
303H0605 | 0.05% | 0-300V | 0-6A | 15KG | XP system |
303H1201 | 0.10% | 0-420V | 0-12A | 18KG | XP system |
303H1205 | 0.05% | 0-420V | 0-12A | 18KG | XP system |
303H2001 | 0.10% | 0-420V | 0-20A | 20KG | XP system |
303H2005 | 0.05% | 0-420V | 0-20A | 20KG | XP system |