GF3000 Multi-Positions Three Phase Energy Meter Test Bench

  • Audited Supplier
  • 14 yrs

Contact Supplier

Product Highlights

  • High Precision Accuracy: Offers 0.02%, 0.05%, and 0.1% accuracy levels for reliable energy meter calibration.
  • Multi-Position Calibration: Supports 3, 6, 12, 20, 24, 40, or 48 meter positions for simultaneous testing.
  • Wide Current Range: Covers 1mA to 120A with automatic switching and high resolution measurement.
  • Comprehensive Harmonic Analysis: Sets 2nd-51st harmonics and displays waveform distortion and harmonic charts.
  • Full Automatic Operation: Features automatic, semi-automatic, and manual modes with barcode input support.
  • Lifetime Technical Support: Provides life time support for all after-sales service needs.
  • Multi-Standard Compliance: Compatible with IEC 60736, IEC 62053, ANSI C12.20, and various national standards.
  • Advanced Power Stability: Ensures high stability up to 0.01%/100s with low distortion under 0.3%.

Product Images of GF3000 Multi-Positions Three Phase Energy Meter Test Bench

GF3000 Multi-Positions Three Phase Energy Meter Test Bench
GF3000 Multi-Positions Three Phase Energy Meter Test Bench pictures & photos
GF3000 Multi-Positions Three Phase Energy Meter Test Bench
GF3000 Multi-Positions Three Phase Energy Meter Test Bench pictures & photos
GF3000 Multi-Positions Three Phase Energy Meter Test Bench
GF3000 Multi-Positions Three Phase Energy Meter Test Bench pictures & photos
GF3000 Multi-Positions Three Phase Energy Meter Test Bench
GF3000 Multi-Positions Three Phase Energy Meter Test Bench pictures & photos
GF3000 Multi-Positions Three Phase Energy Meter Test Bench
GF3000 Multi-Positions Three Phase Energy Meter Test Bench pictures & photos
GF3000 Multi-Positions Three Phase Energy Meter Test Bench
GF3000 Multi-Positions Three Phase Energy Meter Test Bench pictures & photos
GF3000 Multi-Positions Three Phase Energy Meter Test Bench
  • GF3000 Multi-Positions Three Phase Energy Meter Test Bench
  • GF3000 Multi-Positions Three Phase Energy Meter Test Bench
    GF3000 Multi-Positions Three Phase Energy Meter Test Bench
  • GF3000 Multi-Positions Three Phase Energy Meter Test Bench
    GF3000 Multi-Positions Three Phase Energy Meter Test Bench
  • GF3000 Multi-Positions Three Phase Energy Meter Test Bench
    GF3000 Multi-Positions Three Phase Energy Meter Test Bench
  • GF3000 Multi-Positions Three Phase Energy Meter Test Bench
    GF3000 Multi-Positions Three Phase Energy Meter Test Bench
  • GF3000 Multi-Positions Three Phase Energy Meter Test Bench
    GF3000 Multi-Positions Three Phase Energy Meter Test Bench
  • GF3000 Multi-Positions Three Phase Energy Meter Test Bench
    GF3000 Multi-Positions Three Phase Energy Meter Test Bench

Find Similar Products

Product Description

Product Description

GF3000 Multi-Positions Three Phase Energy Meter Test BenchGF3000 Multi-Positions Three Phase Energy Meter Test BenchGF3000 Multi-Positions Three Phase Energy Meter Test BenchGF3000 Multi-Positions Three Phase Energy Meter Test BenchGF3000 Multi-Positions Three Phase Energy Meter Test Bench

The GF3000 series stationary three phase energy meter test bench is a fully automatic system that enables simultaneous, multi-position calibration and verification of three-phase electric energy meters error. Full compatibility with IEC 60736, excellent parameters, superior functionality and outstanding flexibility, It adopt the most advanced electronic measurement technique and modular concept combine the difference three phase reference standards and power amplifier. GF3000 three phase meter test equipment is applied in the measurement centre of grid company energy measurement department of power supply company and energy management utility, industrial enterprise and meter manufacturers.

Our Advantages

FUNCTIONS

Timing error test.

Creeping and starting test.

Equipped with RS232 communication port.

Calibration and verification of constant.

Standard deviation, 24 hour variation test.

Influencing quantity test of voltage, frequency, harmonic.

Able to check the same type meters with different constants.

Full automatic, semi automatic and manual operation available.

Supporting bar code input, which increase the efficiency of input

Testing energy registers (dial test) and maximum demand indicator.

Able to print out all kinds of test reports with the standard forms.

Able to calibrate all kinds of electronic and inductive three phase kWh meter.

Forward and reverse active energy / forward and reverse reactive energy error test.

Able to test voltage, current, active/reactive/apparent power, phase, power factor, frequency, and etc.

Able to display waveform of voltage and current able to set 2nd-51st harmonic of voltage and current, measure the waveform distortion and harmonic content, and display harmonic chart.

Able to perform automatic measurement like shunting, basic errors, standard deviation, and etc.

 

FEATURES

With Multi-channel server;

Operate automatically or manually;

High resolution of voltage, current and power;

Every meter position have error calculation/monitor;

Large LCD display and simple interface for operation;

Wide current measuring range from 1mA to 120A which can be automatically switched;

Self-check and perfect protection function of overload, short voltage circuit and open current circuit;

High stability of power source which is up to 0.01%/100s and low distortion which is no more than 0.3%;

High accuracy, 6-digit display the energy relative errors are no more than 0.05%(0. 1%)within the measuring range;

Installing the ICT in each meter position to test three-phase meters with closed links between the current and voltage measuring circuits (I-P Links) (optional);

Equipped with three phase multifunction reference meter and program-conrolled three phase power source which can be separately used and are convenient for testing


 

Product Parameters

PARAMETERS

Electrical parameters
Accuracy 0.02%, 0.05%, 0.1%
Power Supply AC 180-265V, or 3×220/380V±15%, frequency 50/60Hz.
AC Voltage Output
Range(U1, U2, U3) 57.7V, 100V, 220V, 380V (max 480V)
Adjustment range (0-120)%RG(1)
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability 0.01%/120s
Distortion 0.3% (Non-capacitive load)
Output load 1500VA
Measuring accuracy 0.02%RG or 0.05% RG
AC Current Output
Range(I1,I2,I3) 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 25A, 50A, 100A, 120A
Adjustment range (0-120)%RG
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability <0.01%/120s
Distortion ≤0.3% (Non-capacitive load)
Output load 1500VA
Accuracy 0.02%RG or 0.05% RG
Power Output
Active power output stability <0.01%RG/120s
Reactive power output stability <0.02%RG/120s
Active power measuring accuracy 0.02%RG or 0.05% RG
Reactive power measuring accuracy 0.1%RG
Phase Output
Output adjustment range 0°-359.999°
Output adjustment fineness 10, 1, 0.1, 0.01 as optional.
Resolution 0.01°
Accuracy 0.02° or 0.05°
Power Factor
Adjustment range -1 ~ 0 ~ 1
Resolution 0.0001
Measurement accuracy 0.0005
Frequency Output
Adjustment range 40Hz-70Hz
Output adjustment fineness 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution 0.001Hz
Accuracy 0.002Hz
Voltage /Current/Harmonic Setting
Harmonic number 2-51times
Harmonic content 0-40%
Harmonic phase 0-359.99
Harmonic setting accuracy (10%±0.1%)RD(2)
Power Energy Measurement Error
Active power energy 0.02%RG or 0.05% RG
Reactive power energy 0.1%RG
Power Pulse Output
Power pulse type active pulse, reactive pulse
Active power pulse output 5V, 10mA
Pulse output frequency Max 50kHz
Power Pulse Input
Pulse constant set range (1--599999999)/kwh
Energy pulse type support active and reactive pulse, the highest frequency power pulse input is 200KHz.
Meter Position
Position 3, 6, 12, 20, 24, 40, 48pcs meter
Standard
Standard IEC 62053-21,22, 23; IEC 60736; ANSI C12.20-2002;
JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019;
DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016;
EN 50470-1, EN 50470-2, EN-50470-3; IEC 61010;
Safety
Isolation protection IEC 61010-1:2001
Measurement Category 300 V CAT III, 600 V CAT II
Degree of protection IP20
Declaration of conformity CE & CNAS certified
Mechanical parameters
Dimensions (mm) Cabinet size: 800 * 600 * 1850mm (L * W * H).
Bench size: 2400 * 760 * 1846mm (L * W * H).
Weight (kg) About 235
Environmental conditions
Ambient temperature 0°C to +40°C
Relative humidity 35%-85%
(1) RG means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.

About the Supplier

Watch Video
Watch Video
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.

About Our Factory & Business Background

Address
Bldg. 2-1111, Joy Mansion, No. 99 Chaoyang North Road, Chaoyang District, Beijing, China
Terms of Payment
LC, T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, CIF, FCA, EXW
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
TIANJING

Our Production Capability & Technical Expertise

Main Products
Current Transformer, Energy Meter Calibration, Power Quality Analyzer, Test Equipment, CT PT Analyzer, Relay Test Equipment, Split Core Current Transformer, Current Probe, Voltage Transformer, Power Meter

Our Industry Experience & Global Business Record

Export Year
2010-08-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What accuracy levels are available for the GF3000 test bench?
The GF3000 series offers three accuracy levels: 0.02%, 0.05%, and 0.1%.
How many meters can be tested simultaneously?
The system supports multiple positions including 3, 6, 12, 20, 24, 40, and 48 meters.
What is the warranty period for this equipment?
We provide a three-year warranty for the GF3000 series test bench.
Does the system support harmonic analysis?
Yes, it can set 2nd-51st harmonics, measure waveform distortion, and display harmonic charts.
What standards does the test bench comply with?
It complies with IEC 60736, IEC 62053-21/22/23, ANSI C12.20, and various other national and international standards.
What is the current measuring range?
The wide current measuring range is from 1mA to 120A, which can be automatically switched.
What after-sales service is provided?
We offer life time support for all after-sales service requirements.
Can the system operate automatically?
Yes, it supports full automatic, semi-automatic, and manual operations, including barcode input.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Product Groups

Product Catalogs