Application: Electronic, Instrument
Type: Voltage Transformer
Phase: Single
Operation Condition: Indoor
Usage: Protection, Measurement
Winding Form: Single Layer & Tightly Wound Type
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GFJDZ0227-10Q
Insulating Medium
Epoxy Resin
Installation
Strut Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Keyword
11kv Voltage Transformer PT
Model
11kv PT Instrument Transformer Vt
Gfjdz0227-10q
11kv Vt PT Voltage Transformer
Standards
IEC60044; IEC 61869; ANSI/IEEE C57.13
Rated Voltage
10kv, 6kv
Rated Load
25va
Rated Frequency
50Hz or 60Hz
Material
Epoxy Resin
Weight (Kg)
28
Color
Red
Transport Package
Standard Export Wooden Box
Specification
28KG
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
10000pieces/Month

Product Description

Factory Direct Sale 11kv Voltage Instrument Transformer PT

The Model GFJDZ0929-10 11KV dry-type voltage instrument transformer is a single-phase multi-winding whole sealing epoxy pouring product. It is installed in indoor medium voltage switchgear for measurement of voltage and electric energy as well as relay protection in the electric system of rated frequency 50/60Hz and rated voltage 12kV or below. Design by Standards IEC60044-2, IEC61869-3, and ANSI/IEEE C57.13.

Factory Direct Sale 11kv Voltage Instrument Transformer PT

Parameters
Technical parameters
Standards IEC60044; IEC 61869; ANSI/IEEE C57.13
Rated Voltage 10KV, 6KV
Rated load ≤25VA
Rated frequency 50Hz or 60Hz
Cosø 0.8 (lag)
Phase number Single
Rated insulation level 12/42/75KV, 7.2/32/60KV
Class of pollution II
Mechanical parameters
Material Epoxy resin
Weight (kg) 28
Operating conditions
Operating temperature -25°C to +55°C
Daily average temp <+40°C
Storage temperature -40°C to +70°C
Altitude <1000 meters
Condition No existence of severely begrimed, erosive, and radioactive gas in the air. Permission of long-term operation under rated current.
Technical parameters
Model Rated Voltage Ratio(KV) Accuracy class combination Rated Output
(VA)
Limiting Therminal Output(VA)
GFJDZ0929-10 10/0.1/0.1 0.2/0.2
0.2/0.5
0.5/0.5
20/20
20/20
25/25
400
GFJDZ0929-6 6/0.1/0.1
 