Customization: | Available |
---|---|
After-sales Service: | 24h, 7days |
Warranty: | 3 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
GF6018A Portable Multi-Function Digital Meter Tester is compliance with national verification regulation: JJG124-2005 "Ammeter, voltmeter, power meter and resistance meter verification rules" and related national standards. 0.05 single-phase AC/DC standard source, can verify magnitude 0.2 and the following AC/DC voltmeter, ammeter, frequency meter, resistance meter. The source signals by using DSP and 16-bit high-speed analog-to-digital converters of controllable sine wave, the distorted wave signal source.The equipment comes with RS-232 interface, can be connected with PC to a semi-automatic verification system. It has precise interface and multi-functions including verification, storage and query.The equipment adopts color LCD screen, chart character display is clear, with high precision, stable and reliable, convenient operation and flexible characteristics.
1. The device consists of a single-phase AC voltage standard resource, current standard resource and DC voltage, current standard resource of standard resource.
2. Have calibration function, which can accord to the standard of external value, fixed standard resource output values.
3. The setting of the range for verification 1999 (9), 3999 (9) a display of the digital multimeter.
Frequency output
Sine wave output range (using AC voltage, current output provide)
(45-65) N Hz (N = 1, 2, 3, ...31);
Fineness 0.001 N Hz (N = 1, 2, 3, ...31);
The setting accuracy 5 x 10-5;
Point 1 KHz square wave frequency output, 5 KHz, 10KHz, 50KHz, 100KHz, 200KHz, 1000KHz;
Square wave amplitude 4.5 V;
Electronic resistance box output
Quantity process
0 ~ 200 Ω , 200 ~ 400 Ω , 0 ~ 2 K Ω , 2 K Ω ~ 4 K Ω , 0 ~ 20 K Ω , 20 K Ω ~ 40 K Ω , 0 ~ 200 K Ω , 200 K Ω ~ 400 K Ω , 0 ~ 2 M Ω , 2 M Ω ~ 4 M Ω ;
Fineness 0.025%;
Setting accuracy ± (0.12% RD + 0.08% FS).
Work power
Single-phase AC 220 V± 10%, Frequency 50/60 Hz
Use of the environment
Relative humidity ≤ 85% RH.
Volume and weight
440 mm x 450 mm x 160 mm, about 12 kg
Current/voltage output |
AC | DC |
Voltage range | 200 mA-1000 | 200 mA-1000 |
Current range | 20μA--20A | 20μA--20A |
Adjusting range | 0 ~ 120% | 0 ~ 120% |
Adjust fineness | 5 x 10-5 | 5 x 10-5 |
output capacity | 20 VA | Current: 30W |
Voltage: 20W | ||
adjustment for accuracy | ± (0.03% RD + 0.02% FS) | ± (0.03% RD + 0.02% FS) |
stability | ≤ 0.01% / 60 s | ≤0.01% / 60 s |
waveform distortion degree | ≤0.3% | |
output ripple | ≤1%. |