Customization: | Available |
---|---|
After-sales Service: | 24 Hours Service |
Warranty: | 3 Years Warranty |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
This device is according to nation verification regulation JJG124-2005 "ammeter, voltmeter, power meter and resistance meter calibration regulations and the relevant countries standard requirements and design three-phase 0.05 magnitude meter source integration calibration device. The core technology of the function of device with digital signal processor (DSP) and 16 high-speed digital converter composed of high precision work frequency communication terminal; The signal source of use is DSP and 16 high-speed digital-to-analog converters can control of the sine wave, distortion wave signal source; Equipment has high precision, stable and reliable, and convenient operation, flexible, and other characteristics; Electric power system is used for electrical measurement is the ideal equipment calibration.
Functions and FeaturesSpecifications | |
AC voltage output | |
Range: | 50 V, 100 V, 200 V, 400 V, 800 V; |
Adjusting range: | (0-120) % RG |
Adjust fineness: | 0.01% RG |
Accuracy: | 0.05% RG |
Stability: | 0.01% / 1 min |
Load capacity: | 25 VA |
Output distortion degree: | ≤ 0.3% or (linear load) |
AC current output | |
Range: | 0.5A, 1A, 2.5A, 5A, 10A, 20A; |
Adjusting range: | (0-120) % RG |
Adjust fineness: | 0.01% RG |
Accuracy: | 0.05% RG |
Stability: | 0.01% / 1 min |
Load capacity: | 25 VA |
Output distortion degree: | ≤ 0.3% or (linear load) |
AC power output | |
Accuracy: | 0.05% RG |
Stability: | 0.01% / 1 min |
Frequency | |
Frequency range: | 45.000 ~ 65.000 Hz |
Resolution: | 0.001 Hz |
Accuracy: | 0.01 Hz |
Power factor output | |
Adjusting range: | -1~0~1 |
Adjust fineness: | 0.0001 |
Accuracy: | 0.0005 |
Phase angle | |
Scope: | 0.00 ° ~ 359.99 ° |
Resolution: | 0.01 ° |
Accuracy: | 0.05 ° |
Voltage/Current harmonic output | 2~31st |
DC voltage output | |
Quantity limit: | 75 V, 150 V, 300 V, 500 V, 1000 V |
Adjusting range: | (0-120) % RG |
Adjust fineness: | 0.005% RG |
Accuracy: | 0.05% RG |
Stability: | 0.01% / 1 min |
Load capacity: | 25 VA |
DC current output | |
Quantity limit: | 0.5A, 1A, 2.5A, 5A, 10A, 20A |
Adjusting range: | (0-120) % RG |
Adjust fineness: | 0.005% RG |
Accuracy: | 0.05% RG |
Stability: | 0.01% / 1 min |
Load capacity: | 25 VA |
Environmental conditions | |
Working temperature: | 0 ~ 40° |
Relative humidity: | ≤ 85% |
Storage conditions: | -30~ 60degrees |
Work power | |
Single phase | AC 220 V± 10%, Frequency 50/60 Hz |
Volume and Weight | |
Size | 460 mm X 430 mm X 185 mm |
Weigth | 18Kg |