LZCK2500-10 SELECTING PRECISION 35KV 50/5A 5P20 RELAY SPLIT CORE ZERO PHASE CT CURRENT TRANSFORMER
LZCK series 5P20 split core zero phase ct current transformer is suitable for current measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system. It is widely used in compact fully insulated ring network switchgears such as ABB-Safe Ring/Safe Plus...and cable distribution boxes. The current transformer can be directly installed at the inlet andoutlet cables.The slice is imported silicon material. Thesemicircular ring core and secondary windings arevacuum poured by insulated resin.
OUTLINE DRAWING
WIRING DIAGRAMS
P1, P2 is primary polarity terminal, S1, S2 is secondary polarity terminal.
P2, S2 is homonymous terminals (subtractive polarity).
PARAMETERSTechnical parameters Mechanical parameters Operating conditions
Standards |
IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006 |
Rated primary current |
500-1500A |
Rated load |
≤20VA |
Rated frequency |
50Hz or 60Hz |
Rated secondary current |
5A or 1A |
Rated short-time thermal current |
40kA, 1S |
Rated continuous thermal current |
120%I1n |
Secondary winding power-frequency voltage |
3kV, 1min |
Instrument security factor |
FS≤10 |
Dimensions (W×D×H) (mm) |
φ120xφ185x100 |
Weight (kg) |
7 |
Operating temperature |
-35°C to +55°C |
Daily average temp |
<+40°C |
Storage temperature |
-40°C to +70°C |
Altitude |
<3500 meters |
Condition |
No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current. |
SELECTION GUIDETypeLZCK2500-10LZCK2500-10PurposeMeasuring current transformerProtection current transformerRatioAccuracy class and rated load(VA)Accuracy class and rated load(VA)
I1/I2 |
0.5 |
1 |
3 |
10P15 |
10P10 |
10P5 |
300/5 |
5 |
5 |
5 |
2.5 |
5 |
7.5 |
400/5 |
5 |
5 |
5 |
2.5 |
5 |
7.5 |
500/5 |
5 |
7.5 |
7.5 |
5 |
7.5 |
10 |
600/5 |
5 |
7.5 |
7.5 |
5 |
7.5 |
10 |
800/5 |
10 |
10 |
10 |
5 |
10 |
15 |
1000/5 |
10 |
15 |
15 |
5 |
10 |
15 |
1200/5 |
15 |
20 |
20 |
10 |
15 |
20 |
1500/5 |
15 |
20 |
20 |
10 |
15 |
20 |
SELECTION GUIDE ModelPrimary rated currentRated loadAperture (mm)Description (mm)Weight (kg)MaterialWater-proof
LZCK-55 |
100-1500A |
≤10VA |
φ55 |
180×138×52 |
2 |
ABS+Resin |
IP65 |
LMCK185-10 |
300-3000A |
≤25VA |
φ185 |
350×283×55 |
4.5 |
ABS+Resin |
IP65 |
LZCK310-10 |
300-600A |
≤10VA |
φ50 |
φ50 x φ110 x 32 |
1 |
Resin |
silicon case (option) |
LZCK322-10 |
30-600A |
≤10VA |
φ50 |
φ50 x φ110 x 52 |
1.6 |
Resin |
silicon case (option) |
LZCK350-10 |
20-600A |
≤25VA |
φ50 |
φ50 x φ110 x 105 |
3.1 |
Resin |
silicon case (option) |
LZCK720-10 |
20-1000A |
≤25VA |
φ60 |
φ80 x φ110 x 50 |
2.1 |
Resin |
silicon case (option) |
LZCK2500-10 |
500-1500A |
≤20VA |
φ120 |
φ120 x φ185 x 100 |
7 |
Resin |
silicon case (option) |
LZCG530-10 |
30-600A |
≤20VA |
φ45 |
φ45 x φ120 x 65 |
2.1 |
Resin |
silicon case (option) |
LZCG930-10 |
100-1500A |
≤25VA |
φ60 |
φ60 x φ155 x 60 |
3.6 |
Resin |
silicon case (option) |
LZCT722-10 |
20-600A |
≤10VA |
φ82 |
φ82 x φ130 x 55 |
2.3 |
Resin |
silicon case (option) |
ORDERING INFORMATION
Be sure to the type, current ratio, accuracy class, rated load and use of the products when you plan to make a order. Special specifications could be customized.All kinds of different specifications and parameters current transformers can be made according to your needs.