4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer

  • Audited Supplier
  • 14 yrs

Contact Supplier

Product Highlights

  • High Precision Options: Available in 0.2% and 0.5% accuracy grades for reliable measurement.
  • Flexible Input Range: Supports AC 0-5A current and AC 0-500V voltage with optional configurations.
  • Versatile Output Types: Offers DC current, voltage, and RS485 digital sensor outputs for various needs.
  • Standard DIN Installation: Fits 35mm DIN sliding-way or M4 screws for easy mounting in panels.
  • Strong Insulation Safety: AC 2kV insulation voltage ensures safety between input, output, and power.
  • Wide Power Supply Range: Compatible with AC 110V to 330V power supplies for global use.
  • RS485 Communication: Supports RS485 port for digital data transmission and system integration.
  • Compact Dimension: Small size of 110mm x 75mm x 120mm saves space in control cabinets.

Product Images of 4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer

4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer pictures & photos
4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer pictures & photos
4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer pictures & photos
4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer pictures & photos
4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer pictures & photos
4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer pictures & photos
4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
  • 4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
  • 4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
    4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
  • 4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
    4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
  • 4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
    4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
  • 4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
    4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
  • 4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
    4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
  • 4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer
    4-20 Ma Three Phase Four Wire Active & Reactive Power Transducer

Find Similar Products

Product Description

FUD-P4(Q4) 4-20 mA Three Phase four wire Active & Reactive Power Transducer

Function & Feature
Adopted SCM technique; Excellent stability.
Delivering the direction of measured power accurately.
Applicable for active/reactive power measurement in 3P4W.
The product is customized for multi-quantity-combined transducer of current, voltage, power and all quantity measurement in 3P4W, RS485 port support.
FUD-Type-Input-Power Supply-Output
Type P4: 3P4W Active Power Transducer
Q4: 3P4W Reactive Power Transducer
AC Input V0: 57V, V1: 100V, V2: 220V, V3: 270V, V4: 400V,
A1: 0~1A, A2: 0~5A.
Power Supply P1: AC110V±10%, P2: AC220V±15%,
P3: AC110V~330V.
DC Output O1: 0~20mA, O2: 0~±20mA, O3: 4~20mA,
O4: 4~12~20mA, O5: 0~1V, O6: 0~±1V,
O7: 0~5V, O8: 0~±5V, O9: RS485.
Example 1: FUD-P4-V2-A2-P2-O8
FUD Series 3P4W Active
Power Transducer
Input: AC220V, ±5A,(±3300W)
Power Supply: AC220V±15%
Output: DC0~±5V
Example 2: FUD-Q4-V2-A2-P2-O8
Details: FUD Series 3P4W Reactive Power Transducer Input: AC220V, ±5A,(±3300var)
Power Supply: AC220V±15%
Output: DC0~±5V
Please check the Type, Input range, Output range and Power supply at your order.
 
Technical Index
 
Standard GB/T 13850-1998, IEC688:1992
Accuracy 0.2%, 0.5%
Consumption ≤5VA
Insulation Voltage AC 2kV/min.1mA (Between Input ~ Output / Power)
Insulation Resistance ≥20MΩ (DC500V)
Surge voltage 5KV (Peak Value), 1.2/50μs
Response Time ≤350ms
Input Range AC 0~5A ,AC 0~500V(Optional), 50/60Hz
Absorbed Power Per phase Voltage:≤0.5VA/220V
Per phase Current:<0.1VA/5A
Overload Current: 2 times continuous,30 times /1s .Voltage: 2 times continuous
Load Resistance Current output: RL≤650Ω
Voltage output: RL≥2kΩ
Working environment Temperature: -10~50
RH: 20~90%, Without condensation
Storage conditions Temperature: -40~70
RH: 20~95%, Without condensation
Installation 35mm DIN Sliding-way or M4 screws
Dimension 110mm×75mm×120mm
4-20 Ma Three Phase Four Wire Active &amp; Reactive Power Transducer
 

About the Supplier

Watch Video
Watch Video
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.

About Our Factory & Business Background

Address
Bldg. 2-1111, Joy Mansion, No. 99 Chaoyang North Road, Chaoyang District, Beijing, China
Terms of Payment
LC, T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, CIF, FCA, EXW
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
TIANJING

Our Production Capability & Technical Expertise

Main Products
Current Transformer, Energy Meter Calibration, Power Quality Analyzer, Test Equipment, CT PT Analyzer, Relay Test Equipment, Split Core Current Transformer, Current Probe, Voltage Transformer, Power Meter

Our Industry Experience & Global Business Record

Export Year
2010-08-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What accuracy levels are available?
The transducer is available in 0.2% and 0.5% accuracy grades.
What is the input range for current and voltage?
Input range is AC 0-5A for current and AC 0-500V (optional) for voltage.
What output types does this transducer support?
It supports DC current (0-20mA, 4-20mA), DC voltage (0-10V, etc.), and RS485 digital output.
How is the device installed?
It can be installed on a 35mm DIN sliding-way rail or using M4 screws.
What is the insulation voltage rating?
The insulation voltage is AC 2kV/min.1mA between input, output, and power.
Does it support RS485 communication?
Yes, the product supports RS485 port for digital sensor output and communication.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

People who viewed this also viewed

Product Groups

Product Catalogs