• Three Phase AC DC Ammeter Voltmeter Power Meter Calibrator
  • Three Phase AC DC Ammeter Voltmeter Power Meter Calibrator
  • Three Phase AC DC Ammeter Voltmeter Power Meter Calibrator
  • Three Phase AC DC Ammeter Voltmeter Power Meter Calibrator
  • Three Phase AC DC Ammeter Voltmeter Power Meter Calibrator
  • Three Phase AC DC Ammeter Voltmeter Power Meter Calibrator

Three Phase AC DC Ammeter Voltmeter Power Meter Calibrator

After-sales Service: 24 Hour Service
Warranty: 3 Years
Application: Electromagnetic Instrument, Electrical Calibrator
Power: Electricity
Certification: FDA, CE, IAF, CCC, Ilac.Mra
Voltage Output: 0-1000V
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF3600
Current Output
0-100A
LCD Display
With LCD Display
Customized
Non-Customized
Hot Searching
Ammeter Voltmeter Power Meter Ca
AC Voltage Signal Output
0V--800V
AC Current Signal Output
0A--100A
Voltage / Current Harmonic Output
2--31st
Operating Temperature
0 ~ 40°
Dimensions
1800 mm X 800 mm X 750 mm
Frequency
45--65Hz
Adjust Fineness
5 X 10-5
Accuracy
0.05%
Transport Package
Standard Export Box
Specification
EN 61010-1, CE, ISO9001: 2008, IEC
Trademark
GFUVE
Origin
Beijing, China
HS Code
9030849000
Production Capacity
100PCS/ Month

Product Description

GF3600 Three Phase AC DC ammeter voltmeter power meter calibrator
The device is composed of Program-Controlled Three-Phase standard power resource, DC standard power source, Three Phase Multifunction Reference standard meter, computer and management software. The technical index of the device is compliance with national industry related standards and verification regulation. It can be used at power Grid Company, power Supply Company and power plants for measuring and testing power institutions, also it can be applied at railway, petroleum, chemical industry and mining enterprises, etc.
FEATURES
Normal indicating instrument
Power frequency and dc digital instrument
Transducer
Electric energy meter
Error of the ac sample
The meters it can the verify: AC/DC voltmeter, ammeter, single/three-phase active, reactive power meter, phase meter, for access to power, frequency meter, synchronous meter, etc.
The transducers types it can verify, AC/DC voltage transducer, current transducer, single/three-phase active, reactive power transducer, phase transducer, a power factor transducer, frequency transducers.
The watt-hour meters types it can verify: electronic type and inductive single-phase and three-phase meritorious electric energy meter and reactive watt-hour meter.
Can be set and measuring 2-31 times harmonic.
Wide measuring range, high stability, high resolution, low distortion degree.
Automatic data rounding, various forms of certificate format, inquires and print convenient
Under the computer control, it can realize the automatic verification for watt-hour meters and transducers, semi-automatic verification for all kinds of instruction machine
Its block structure, convenient for inspection and it can be used independently
Automatic failure detection can avoid the damage of equipment which caused by wrong operation
PARAMETERS

Electrical parameters
Accuracy class  0.05%, 0.1%
Power supply AC 220V ± 10% or AC 110V ± 10%, 50/60Hz
AC Voltage output and measurement
U1, U2, U3 Range 10V, 20V, 50V, 100V, 200V, 400V, 800V
Output range (0-120%)% RG
Adjustment resolution 0.01% RG
Output stability 0.01%/min
Measurement accuracy 0.05% RG
Output load capability 50VA
Measurement resolution ≤5×10-5 RG
AC Current output and measurement
I1, I2, I3 Range 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 25A, 50A, 100A
Output range (0-120)% RG
Adjustment resolution 0.01% RG
Output stability 0.01%/min
Measurement accuracy 0.05% RG
Output load capability 100VA 
Measurement resolution ≤5×10-5 RG
Power output and measurement
Output stability 0.01%/1min
Active accuracy 0.05% RD (0.01A-100A, 30V-600V, PF ≥0.5L or PF ≥0.8C)
Reactive accuracy 0.1% RD (0.01A-100A, 30V-600V, PF ≥0.5)
Measurement resolution ≤5×10-5 RG
Energy measurement
Active accuracy 0.05% RD (0.01A-100A, 30V-600V, PF ≥0.5L or PF ≥0.8C), 
0.1% RD (0.05A-100A, 30V-600V PF ≥0.5C)
Reactive accuracy 0.1% RD 0.05A-100A, 30V-600V PF ≥0.5
Setting range of test pulse No. 1-9999999
Max. frequency of receiving pulse 2MHz
Phase output and measurement
Output range 0°-359.99°
Adjustment resolution 0.01°
Measurement accuracy 0.05°
Measurement resolution 0.001°
Power factor output and measurement
Output range -1 to 0 to +1
Measurement accuracy 0.0005
Measurement resolution 0.0001
Frequency output and measurement
Output range 45-65Hz
Adjustment resolution 0.001Hz
Measurement accuracy 0.005Hz
Measurement resolution 0.001Hz
Harmonic
Times 2 to 31
Resolution 0.1% (compared with fundamental wave)
Contents 0-30%
Phase 0°-359.99°
DC Voltage output
Range 100mV, 300mV, 1V, 3V, 10V, 30V, 100V,  300V, 600V, 1000V
Setting range 0-1000V
Regulated step value 0.002% RG
Accuracy 0.03% RD + 0.02% RG
Stability 0.01%RG/1min
Output load capability 25VA 
Ripple wave and noise 0.1-100KHz
Output ≤100 V Ripple wave ≤2mVrms
Output > 100 V Ripple wave ≤10mVrms
DC Current output
Range 10μA, 30μA, 100μA, 300μA, 1mA, 3mA, 10mA, 30mA, 100mA, 300mA, 1 A, 3 A, 10 A, 30 A
Setting range 0-30A
Regulation resolution ≤0.02% RG
Accuracy 0.03% RD + 0.02% RG
Stability 0.01%RG/1min
Output load capability 30VA 
Mechanical parameters
Dimension (L×W×H) (mm) 1800x800x750
Weight (kg) 135
Environmental conditions
Operating temperature 0°C to 40°C
Relative humidity ≤85%
Three Phase AC DC Ammeter Voltmeter Power Meter Calibrator