• Three Phase Electric Meter Calibration Equipment with Printer
  • Three Phase Electric Meter Calibration Equipment with Printer
  • Three Phase Electric Meter Calibration Equipment with Printer
  • Three Phase Electric Meter Calibration Equipment with Printer
  • Three Phase Electric Meter Calibration Equipment with Printer
  • Three Phase Electric Meter Calibration Equipment with Printer

Three Phase Electric Meter Calibration Equipment with Printer

Warranty: Three Years
Application: Chemical Instrument, Thermal Power, Mechanical Instrument, Length Instrument, Time Frequency Instrument, Electromagnetic Instrument, Radio Apparatus
Power: Electricity
Certification: FDA, CE, IAF, CCC
Voltage Output: 600V
Current Output: 20A
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF312B
LCD Display
With LCD Display
Customized
Customized
Accuracy Class
0.05, 0.1%, 0.2%
Harmonic
2ND-63st
Phase Angle Range
0 ~ 360
Frequency Range
45Hz-65Hz
Power Factor Range
-1 ~ 0 ~ 1
Keyword
Three Phase Electric Meter Calibration
Model
Three Phase Electric Meter Calibration Equipment
GF312b
Three Phase Electric Meter Calibration Equipment W
Host Weight (mm)
3
Relative Humidity
30%-85%
Transport Package
Standard Export Wooden Box
Specification
390*200*160mm
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
100sets/Month

Product Description

Three Phase Electric Meter Calibration equipment with Printer
GF312B portable three phase electric meter calibration equipment with printer is used to calibrate three phase, single phase, active and reactive watt meters. And it also can be used as voltage, current and power meter to measure AC parameters of three phase power line.It can measure wave distortion factor and 2nd to 63th harmonic wave.
Features
Three phase active or reactive electricity energy meter
Calibrate three phase, single phase, active or reactive meter error
Measure U(voltage) of three phase or single phase
4Measure I(current) of three phase or single phase
Measure active power of three phase or single phase
Measure reactive power of three phase or single phase
Measure apparent power of three phase or single phase
Measure power factor of three phase or single phase
Measure phase angle between voltage and current
Measure frequency of power line
Display vector diagram
Display waveform of U and I
Analyze and display content of harmonic of U and I
Store and check measured data
Optional 5A, 20A, 100A, 500A, 1000A, 2000A, 3000A current clamp
Measure CT variable ratio
Print the data of measurement on site
Parameters
Electrical parameters
Accuracy class 0.05, 0.1%, 0.2%
Power supply 220V ± 10% or 110V ± 10%, 50/60Hz ± 2Hz
Test Voltage
Range 0V-600V
Error ±0.05% (30V-600V)
±0.1% (5V-30V)
Harmonic 2nd-63st
Test Current
Range (direct connection) 20mA-20A
Error (direct connection) ±0.05% (100mA-20A)
±0.1% (20mA-100mA)
Range (Clamp CT) 10mA-3000A
Error (Clamp CT) ±0.2% (100mA-3000A)
±0.5% (10mA-100mA)
Harmonic 2nd-63st
Power measure error
Active power (direct connection) ±0.05% (0.1A-20A)
±0.1% (0.02A-0.1A)
Reactive power (direct connection) ±0.1% (0.1A-20A)
Energy measure error
Active energy (direct connection) ±0.05% (0.1A-20A)
±0.1% (0.02A-0.1A)
Reactive energy (direct connection) ±0.1% (0.1A-20A)
Phase angle
Range 0° ~ 360°
Resolution 0.01°
Error ±0.05°
Frequency
Range 45Hz-65Hz
Resolution 0.001Hz
Accuracy 0.005Hz
Power factor
Range -1 ~ 0 ~ 1
Resolution 0.0001
Error 0. 0005
Pulse output  
Energy constant 180000imp/kWh, 1800imp/kWh, 18imp/kWh
Pulse ratio 1:1
Output level 5V
Pulse input
Input channel 1
Input level 5-24V
Input frequency Max. 2MHz
Display
Resolution 6"TFT (640×480)
Function
Vector diagram Yes
Waveform Yes
Energy accumulation Yes
Communication port RS232
Communication with PC Yes
Mechanical parameters
Dimensions (W×H×D) (mm) 390×200×160
Host Weight (mm)  3
Weight (including Accessories 3pcs 100A clamp CT) (kg) 12
Environmental conditions
Ambient temperature -10°C to 40°C
Relative humidity 30%-85%
Three Phase Electric Meter Calibration Equipment with Printer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now