Test-901 Instrument Large 1000A Primary Current Injection for Test Set

  • Audited Supplier
  • 14 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Powerful Current Output: Delivers up to 1100A primary current with 5KVA capacity for robust testing.
  • Advanced Control System: Features ARM Chip control with LCD display and built-in digital ammeter.
  • Comprehensive Protection: Includes thermal, short-circuit, and dual electronic/software overload protection.
  • Portable Design: Compact aluminum alloy body with PC panel, weighing only 25kg for easy site testing.
  • Precision Timer Function: Built-in digital timer with 1ms resolution and range up to 999.999 seconds.
  • Wide Application Scope: Ideal for CT ratio, protective relay, circuit breaker, and ground grid testing.
  • Standard Compliance: Meets IEC61010-1 and IEC 61326-1 safety and performance standards.

Product Images of Test-901 Instrument Large 1000A Primary Current Injection for Test Set

Test-901 Instrument Large 1000A Primary Current Injection for Test Set
Test-901 Instrument Large 1000A Primary Current Injection for Test Set pictures & photos
Test-901 Instrument Large 1000A Primary Current Injection for Test Set
Test-901 Instrument Large 1000A Primary Current Injection for Test Set pictures & photos
Test-901 Instrument Large 1000A Primary Current Injection for Test Set
Test-901 Instrument Large 1000A Primary Current Injection for Test Set pictures & photos
Test-901 Instrument Large 1000A Primary Current Injection for Test Set
Test-901 Instrument Large 1000A Primary Current Injection for Test Set pictures & photos
Test-901 Instrument Large 1000A Primary Current Injection for Test Set
Test-901 Instrument Large 1000A Primary Current Injection for Test Set pictures & photos
Test-901 Instrument Large 1000A Primary Current Injection for Test Set
  • Test-901 Instrument Large 1000A Primary Current Injection for Test Set
  • Test-901 Instrument Large 1000A Primary Current Injection for Test Set
    Test-901 Instrument Large 1000A Primary Current Injection for Test Set
  • Test-901 Instrument Large 1000A Primary Current Injection for Test Set
    Test-901 Instrument Large 1000A Primary Current Injection for Test Set
  • Test-901 Instrument Large 1000A Primary Current Injection for Test Set
    Test-901 Instrument Large 1000A Primary Current Injection for Test Set
  • Test-901 Instrument Large 1000A Primary Current Injection for Test Set
    Test-901 Instrument Large 1000A Primary Current Injection for Test Set
  • Test-901 Instrument Large 1000A Primary Current Injection for Test Set
    Test-901 Instrument Large 1000A Primary Current Injection for Test Set

Find Similar Products

Product Description

TEST-9011000A PRIMARY CURRENT INJECTION TEST SET

TEST-901 primary current injection test set adopts ARM Chip to control its output process and large capacity of toroidal transformers. It is equipped with LCD display and current meter; it can show primary current value, second current value, turn ratio and the action time of circuit breaker. Packing is used as aluminum alloy body with PC panel. TEST-901 is mainly applied to CT turn ratio testing in the power system and contact resistance test which need large current. This model current injection test set is ideal for 1. performance and turn-ratio tests of current transformers; 2. primary tests of protective relays; 3. current tests on low-voltage and high-voltage circuit breakers; 4.commissioning tests that require variable currents
Test-901 Instrument Large 1000A Primary Current Injection for Test SetTest-901 Instrument Large 1000A Primary Current Injection for Test SetTest-901 Instrument Large 1000A Primary Current Injection for Test SetTest-901 Instrument Large 1000A Primary Current Injection for Test SetTest-901 Instrument Large 1000A Primary Current Injection for Test SetTest-901 Instrument Large 1000A Primary Current Injection for Test SetTest-901 Instrument Large 1000A Primary Current Injection for Test SetTest-901 Instrument Large 1000A Primary Current Injection for Test SetTest-901 Instrument Large 1000A Primary Current Injection for Test SetTest-901 Instrument Large 1000A Primary Current Injection for Test SetTest-901 Instrument Large 1000A Primary Current Injection for Test Set
 

FEATURES

Portable designed

Quick and easy to use

With CT ratio test function

With 6m large current cable

Max current output up to 1100A

Built-in digital timer resolution 1ms

Built-in digital ammeter 0.5% accuracy

Permanent current up to 1000 A, 5KVA

Small size, light weight, easy to test on-site

Thermal and short-circuit & overload protection

 

APPLICATION

Switchgear Testing

Ground Grid Testing

Primary injection tests

Circuit Breaker Testing

Protective Relay Testing

Current Transformer Testing

Recloser and Sectionalizers

 

PARAMETERS

Electrical parameters
Accuracy ±0.5%
Power Supply(AC) 220V±10%·25A, 50Hz/60Hz or 110V±10%·50A, 50Hz/60Hz
Current Output (AC) 1000A·5V or 500A·10V
Capacity 5KVA
The current output waveform distortion ≤5%
Dual protection overload electronic protection and software protection
Primary current
Range 0-1100A
Resolution 0.1A
Accuracy <0.5%
Secondary measurement
Range 0-6A
Resolution 0.001A
Accuracy <0.5%
Current duration
1000A range 1000A   2-3minutes
500A   3-6minutes
500A range 500A   2-3minutes
Continuous output 400A
With timer
Range 0.0001~999.999S
Resolution 0.001S
Accuracy <0.2% ±2 words
Standard
Standard IEC61010-1;IEC 61326-1
Communication port RS232
Cable length 2x6m, 70mm²
Mechanical parameters
Dimensions (W×D×H) (mm) 430×260×260
Weight(kg) 25
Environmental conditions
Operating Temperature -10°C to 50°C
Storage Temperature -40°C to 70°C
Relative humidity ≤95%,on-condensing

SELECTION GUIDE

Model Accuracy Primary Current Ammeter(0-6A) Timer Power Injection Current time Dimension(W×D×H) (mm) Weight Remark
TEST-901 0.5% 0-1100A YES YES 5KVA 1000A: 2-3min;
500A:3-6min
430×260×260 25KG Integrated structure
TEST-902 0.5% 0-2200A YES YES 12KVA 2000A:2-3min;
1000A:3-6min
360×300×295 and 320×300×300 35KG+15KG Fission structure
TEST-903 0.5% 0-3300A YES YES 15KVA 3000A: 2-3min;
1500A:3-6min
380×350×360 and 340×290×420 48KG+42KG Fission structure
TEST-905 0.5% 0-5500A YES YES 30KVA 5000A:2-3min;
2500A:3-6min
430×430×445 and 550×450×600 68KG+55KG Fission structure

About the Supplier

Watch Video
Watch Video
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.

About Our Factory & Business Background

Address
Bldg. 2-1111, Joy Mansion, No. 99 Chaoyang North Road, Chaoyang District, Beijing, China
Terms of Payment
LC, T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, CIF, FCA, EXW
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
TIANJING

Our Production Capability & Technical Expertise

Main Products
Current Transformer, Energy Meter Calibration, Power Quality Analyzer, Test Equipment, CT PT Analyzer, Relay Test Equipment, Split Core Current Transformer, Current Probe, Voltage Transformer, Power Meter

Our Industry Experience & Global Business Record

Export Year
2010-08-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the maximum primary current output?
The TEST-901 can output a maximum primary current of 1100A.
How long can the device sustain maximum current?
At 1000A, it can run for 2-3 minutes; at 500A, it can run for 3-6 minutes.
What are the main applications of this test set?
It is used for CT turn ratio testing, protective relay primary tests, circuit breaker current tests, and commissioning tests requiring variable currents.
Does the device include a timer function?
Yes, it has a built-in digital timer with a resolution of 1ms and a range of 0.0001 to 999.999 seconds.
What protection mechanisms are built-in?
It features thermal protection, short-circuit protection, and dual overload protection (electronic and software).

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Product Groups

Product Catalogs