Automatic Transformer Tester Portable CT PT Analyzer

Product Details
Customization: Available
Display Type: Digital Only
Certification: CE, IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
>2000 square meters
  • Automatic Transformer Tester Portable CT PT Analyzer
  • Automatic Transformer Tester Portable CT PT Analyzer
  • Automatic Transformer Tester Portable CT PT Analyzer
  • Automatic Transformer Tester Portable CT PT Analyzer
  • Automatic Transformer Tester Portable CT PT Analyzer
  • Automatic Transformer Tester Portable CT PT Analyzer
Find Similar Products

Basic Info.

Model NO.
GF1061
Customized
Customized
Accuracy
0.05%
Power Supply
AC 220 or AC 120V 50/60Hz or Battery
Output Voltage
0-100vrms
Output Current
0-5arms (20A Peak-Value)
Output Power
0-400 Va (1500 Vapeak)
Automatic Frequency Variation Range
0.1-60Hz
Equivalent Excitation Voltage
5000V
Secondary Winding DC Resistance Measurem
0.1-1000Ω T≤0.05%
Secondary Actual Load Measurement
5va-1000va ≤0.5%±0.1va
CT/PT Phase Error Measurement
±1min (Typical) / 3 Min (Guaranteed)
Overall Dimension (L x W x H) (mm)
280 X 250 X 160
Weight (Kg)
4
Relative Humidity Trelative Humidity
5%-95%
Altitude
1000m
Names
Portable CT PT Analyzer
Transport Package
Standard Carton Packaging
Specification
GB1207-2006, GB1208-2006, GB16847-1997 IEC60044-1
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
500 Sets/Year

Packaging & Delivery

Package Size
60.00cm * 55.00cm * 50.00cm
Package Gross Weight
20.000kg

Product Description

 

HV CT PT Analyzer GF1061 Class 0.05 Current Transformer Testing Instrument 

GF1061 portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.
The CT Analyzer is the most complete and easy-to-use test system for protection and metering CTs according to IEEE and IEC standards. It combines the highest safety standards with CT test and assessment features. The CT Analyzer approach.
 Before starting to work, clearly establish the responsibilities. Personnel receiving training, instructions, directions, or education on the CT Analyzer must be under constant supervision of an experienced operator while working with the equipment. The operator is responsible for the safety requirements during the whole test.CT Kneepoints up to 80kV CT grouped testing includes Demagnetization, Knee Points, Ratios, Saturation Curves, Winding Resistances, Polarities and Phase Deviation (on all taps of multi-ratio CTs) VT testing including Demagnetization, Ratio, Winding Resistance, Polarity and Phase Deviation.

Automatic Transformer Tester Portable CT PT Analyzer

MAIN FUNCTIONS

I. Current Transformer (CT) II. Voltage Transformer (PT)
1. Magnetization curve 1. Excitation characteristic test
2. Transformation ratio test 2. Transformation ratio test
3. Polarity 3. Polarity 
4. 5% and 10% error curve 4.  Ratio error, phase error
5. Accuracy limiting factor (ALF) 5. Degauss
6. Degauss 6. Calculation of knee point value
7. Ratio error, phase error 7. Actual secondary load test (burden test)
8. Automatic calculation of excitation knee 
point value
8. Resistance test
9. Actual secondary load test (burden test)
10. Resistance test
11. Secondary time constant (Ts)
12. Remanence coefficient (Kr)
13. Transient dimensioning factor (Ktd)
14. Peak instantaneous error (Er)
15. Magnetizing inductance (LU)
16. Instruments security factor(FS)
17. Composite error

PARAMETERS

Electrical parameters
Accuracy 0.05%
Power supply AC 220V±10% or AC 120V±10%, 50/60Hz or Battery
Output voltage 0-100Vrms
Output current 0-5Arms (20A peak-value)
Output power 0-400 VA (1500 VApeak)
Automatic frequency variation range 0.1-60Hz
Equivalent excitation voltage ≤5000V
Accuracy ≤0.5%
Secondary winding DC resistance measurement Range 0.1-1000Ω
Accuracy ≤0.05%
Secondary actual load measurement Range 5VA-1000VA
Accuracy ≤0.5%±0.1VA
CT/PT phase error measurement Accuracy ±1min (typical) / 3 min (guaranteed)
Resolution 0.1min
CT ratio error measurement Range 1-50000
Accuracy ≤0.05%
PT ratio error measurement Range 1-10000
Accuracy ≤0.05%
Standards
Reference standards GB1207-2006, GB1208-2006, GB16847-1997 
IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Mechanical parameters
Overall dimension (L x W x H) (mm) 280 x 250 x 160
Weight (kg)   ≤4
Environmental conditions
Relative humidity    Relative humidity 5%-95% not condensing
Operating temperature -10°C to +50°C
Storage temperature -20°C to +70°C
Altitude ≤1000m

Photo
Automatic Transformer Tester Portable CT PT AnalyzerAutomatic Transformer Tester Portable CT PT AnalyzerAutomatic Transformer Tester Portable CT PT Analyzer