All kinds of electric measurement transducer can be checked, including: AC/DC voltage transducer, AC/DC current transducer, frequency transducer, phase transducer, single/ three-phase AC active power transducer, 3-phase reactive power transducers;
Check all kinds of electric measurement indicating meter, including: AC/DC voltmeter, AC/DC ammeter, frequency meter, phase meter, single three-phase AC active power meter, three-phase AC reactive power meter, synchronous meter, etc.;
To test single-phase, three-phase electronic, mechanical watt-hour meter or energy meter/ kWh meter error;
To calibrate AC sample device, RTU, measurement device error;
The built-in electric measurement transducer, electric measurement instrument and meter instructions of verification procedures, can fully automatic or semi-automatic for verification, can save 1000 group check data;
As a voltage source, a current source and power source for high precision, and it is high stability standard resource;
8'-inch big screen color display; The system is WINDOW XP or embedded system; English interface.
The software calibration, it does not need to open the case, stable and reliable;
Voltage output terminal with short circuit, current output terminal open protection and power amplifier overheating protection function;
With automatic failure detection function, shows fault part, the convenience users check line;
With RS232 interface, it can connect computer for data management.
Technical DataElectrical parametersAC Voltage outputAC Current outputAC Power outputFrequency outputPower factor outputPhase outputHarmonic configurationDC Voltage outputDC Current outputEnergy ErrorDC Input Voltage MeasurementDC Input Current MeasurementMechanical parametersEnvironmental conditions
Accuracy class | 0.05%, 0.1% |
Power supply | Single phase AC 220V±10% or 110V±10%, 50/60Hz |
Communication port | USB, RS232, RS485, LAN |
Range(U1,U2,U3) | 50V, 100V, 200V, 400V, 600V |
Adjustment range | (0 - 120)% RG |
Adjustment resolution | 0.01% RG, 0.1% RG, 1% RG, 10% RG |
Stability | 0.01% /1min |
Distortion | ≤0.2% (non-capacitive load) |
Max. output load | 25VA for each phase |
Accuracy | 0.05% RG |
Range(I1,I2,I3) | 0.5A, 1A, 2.5A, 5A, 10A, 20A |
Adjustment range | (0 - 120)% RG |
Adjustment resolution | 0.01% RG, 0.1% RG, 1% RG, 10% RG |
Stability | 0.01% /1min |
Distortion | ≤0.2% (non-capacitive load) |
Max. output load | 25VA for each phase |
Accuracy | 0.05% RG |
Active output stability | 0.01%RG/1min |
Reactive output stability | 0.02%RG/1min |
Active accuracy | 0.05% RG |
Reactive accuracy | 0.1% RG |
Adjustment range | 45-65Hz |
Adjustment resolution | 1Hz, 0.1Hz, 0.01Hz and 0.001Hz |
Resolution | 0.001Hz |
Accuracy | 0.002Hz |
Adjustment range | -1 to 0 to +1 |
Adjustment resolution | 0.0001 |
Resolution | 0.0005 |
Adjustment range | 0°-359.999° |
Adjustment resolution | 10°, 1°, 0.1°, 0.01° |
Resolution | 0.001° |
Accuracy | 0.05° |
Times | 2 to 31 |
Content | 0-40% |
Phase | 0°-359.999° |
Configuration error | (10% RD + 0.1%), RD refers to the configuration value of harmonic contents |
Range | 75mV, 75 V, 150 V, 300 V, 500V, 1000 V |
Adjustment range | (0-120)% RG |
Adjustment resolution | 0.01% RG, 0.1% RG, 1% RG, 10% RG |
Stability | 0.01% RG / 1 min |
Distorting | ≤0.2% (non-capacitive load) |
Output load | 25VA |
Accuracy | 0.05% RG |
Ripple contents | ≤1% |
Range | 0.5 A,1A, 2.5 A, 5 A, 10A, 20 A |
Adjustment range | (0-120)% RG |
Adjustment resolution | 0.01% RG, 0.1% RG, 1% RG, 10% RG |
Stability | 0.01% RG / 1min |
Distortion | ≤ 0.2% (non-capacitive load) |
Output load | 25VA |
Accuracy | 0.05% RG |
Ripple contents | ≤1% |
Active error | 0.05% RG |
Reactive error | 0.1% RG |
Range | 0 to ±20V |
Measurement range | (0-120)% RG |
Accuracy | 0.01% RG |
Resolution | 0.001% RG |
Range | 0-20mA |
Measurement range | (0-120)% RG |
Accuracy | 0.01% RG |
Resolution | 0.001% RG |
Dimensions (W×H×D) (mm) | 460x430x185 |
Weight (kg) | 20 |
Working temperature | 0°C to 40°C |
Relative humidity | ≤85% |