Ohmmeter Ammeter and Voltmeter Calibrator with AC|DC Current and Voltage Source

Product Details
Customization: Available
Application: Electromagnetic Instrument
Power: Electricity
Gold Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
>2000 square meters
  • Ohmmeter Ammeter and Voltmeter Calibrator with AC|DC Current and Voltage Source
  • Ohmmeter Ammeter and Voltmeter Calibrator with AC|DC Current and Voltage Source
  • Ohmmeter Ammeter and Voltmeter Calibrator with AC|DC Current and Voltage Source
  • Ohmmeter Ammeter and Voltmeter Calibrator with AC|DC Current and Voltage Source
  • Ohmmeter Ammeter and Voltmeter Calibrator with AC|DC Current and Voltage Source
  • Ohmmeter Ammeter and Voltmeter Calibrator with AC|DC Current and Voltage Source
Find Similar Products

Basic Info.

Model NO.
GF6018A
Voltage Output
0-1000V
Current Output
0~20A
LCD Display
With LCD Display
Customized
Customized
Size
440X450X160mm
Weight
12kg
Relative Humidity
Less Than 85%Rh
Frequency
50/60Hz
Communication Port
RS232 Interface
Display
LCD Display
Harmonic Output
2~31th
Class
0.05%
Frequency Output
45-65Hz
Transport Package
Standard Export Carton
Specification
CE, ISO9001: 2008, IEC
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
200PCS/Month

Product Description

GF6018A ohmmeter ammeter and voltmeter cablibrator with ac|dc current and voltage source
Ohmmeter Ammeter and Voltmeter Calibrator with AC|DC Current and Voltage Source
Ohmmeter Ammeter and Voltmeter Calibrator with AC|DC Current and Voltage Source
Ohmmeter Ammeter and Voltmeter Calibrator with AC|DC Current and Voltage Source
The device is according to verification regulation JJG124-2005 "ammeter, voltmeter, power table and resistance meter calibration regulations, JJF1075-2001" clamp ampere ammeter calibration the requirements of the "standards for the design of 0.05 magnitude AC and DC standard units.The source of the signals of the DSP and 16 high-speed digital-to-analog converters can control of the sine wave, distortion wave source.The display USES graphics standard 240 X 128 LCD monochrome screen
Main Functions and Features
1.The device consists of a single-phase AC voltage standard resource, current standard resource and DC voltage, current standard resource of standard resource.
2.Have calibration function, which can according to the standard of external value, fixed standard resource output values.
3.The setting of the range for verification 1999 (9), 3999 (9) a display of the digital multimeter.
4.Manual and semi-auto inspection 0.2% and below levels of digital multimeter, an analogue meter installation type digital instrument, including DC analog output of digital instrument;All kinds of clamp ampere ammeter;Verification clamp ampere ammeter range for 200 A, 600 A, 1000 A.
5.To generate containing 2 ~ 31 harmonic wave distortion, the harmonic number, number, amplitude and phase of the harmonic wave to base wave all can be programmed control.
6.With RS232 interface and large capacity non-volatile memory, can store 500 blocks are inspection table test data.Through the PC software, the PC control this device automatic and manual inspection, and the results are processing and management.

PARAMETERS
Electrical parametersAC Voltage outputAC Current OutputFrequency OutputHarmonic WaveDC voltage outputDC current outputResistance boxClamp meter rangeDot frequency square wave outputMechanical parametersEnvironmental conditions
Power supply Single phase AC 220V±10% or 110V±10%, 50/60HzAC
range 200mV, 400mV, 2000mV, 4000mV, 
20V, 100V, 200V, 500V, 1000V
Range 20V-1000V Accuracy ±(0.03%RD+0.02%FS)
Stability ≤0.01% FS /60s
Range 200mV-4000mV Accuracy ±(0.3%RD+0.2%FS)
Stability ≤0.04% FS /60s
Load capacity 20VA
Waveform distortion ≤0.3%
Adjustable Range 0-120% FS (1000V not included)
Fineness 5×10-5
Range 2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A
Range 0.2A-20A  Accuracy ±(0.03%RD+0.02%FS)
Stability ≤0.01% FS /60s
Range 2mA-40mA   Accuracy ±(0.3%RD+0.2%FS)
Stability ≤0.04% FS /60s
Load capacity 20VA
Waveform distortion ≤0.3%
Adjustable Range 0-120% FS
Fineness 5×10-5
Range 45-65Hz
Fineness 0.001Hz
Accuracy 0.01Hz
Times 2-31
Extent 0-20%
Each harmonic phase fineness  0.01·N (N is  harmonic order)
Range 200mV, 400mV, 2000mV, 4000mV, 
20V, 40V, 100V, 200V, 400V, 1000V
Load capacity 20W
Adjustable range 0-110% FS (1000V not included)
Adjustable fineness 5×10-5
Stability ≤0.01% FS /60s (peak-peak value)
Accuracy ±(0.03%RD+0.02%FS)
Ripple wave ≤1% FS
Range 20uA, 40uA, 200uA, 400uA, 2mA, 4mA, 
20mA, 40mA, 0.2A, 1A, 2.5A, 5A, 10A, 20A
Load capacity 20W
Adjustable Range 0-110% FS (1000V not included)
Adjustable Fineness 5×10-5
Stability ≤0.01% FS /60s (peak-peak value)
Accuracy ±(0.06%RD+0.04%FS)
Ripple wave ≤1% FS
Range 0-200Ω, 200-400Ω, 0-2kΩ, 2kΩ-4kΩ, 0-20kΩ, 20kΩ-40kΩ, 
0-200kΩ, 200kΩ-400kΩ, 0-2MΩ, 2MΩ-4MΩ
Fineness 0.02%
Range 0-2kΩ, 0-20kΩ, 0-200kΩ 
Range 0-2kΩ  Adjustable Range 0-100%FS
Accuracy ±(0.12%RD+0.08%FS)
Range 0-200Ω,0-2MΩ Adjustable Range 0-100% FS
Accuracy ±(0.3%RD+0.2%FS)
Range 2kΩ-4kΩ, 20kΩ-40kΩ, 200kΩ-400kΩ
Range 2kΩ-4kΩ Adjustable Range 5%-100%FS
Accuracy ±(0.12%RD+0.08%FS)
Range  200-400Ω, 
2MΩ-4MΩ
Adjustable Range 5%-100% FS
Accuracy ±(0.3%RD+0.2%FS)
200A Accuracy ±0.2%
600A Accuracy ±0.5%
1000A Accuracy ±1%
Range 1kHz, 5kHz, 10kHz, 50kHz, 100kHz, 200kHz, 1000kHz
Square wave amplitude 4.5V
Setting accuracy 5×10-5
Dimension (L×W×H) (mm) 440x360x160
Weight (kg) 12
Operating temperature 20°C±10°C
Relative humidity ≤85%RH