Customization: | Available |
---|---|
After-sales Service: | 24 Hour Service |
Warranty: | 3 Years |
Still deciding? Get samples of US$ 80000/Set
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Testing single-phase meters under tampered conditions;
Calibration of lower accuracy reference standard meter;
Able to print out all kinds of test reports with the standard forms;
Calibrate all kinds of electronic and inductive single phase kWh meter;
Influence quantity test (voltage, frequency, harmonic distortion, etc.);
Pre-warming;
Meter constant test;
Starting current test;
Creep test (No-load test);
Dips and Interruptions;
Dial test (Register test);
Equipped with RS232 communication port;
Automatic measurement like shunting, basic errors, standard deviation etc;
Accuracy test in all four quadrants (active, reactive and apparent energy);
Test voltage, current, active/reactive/apparent power, phase, power factor, frequency, and etc;
Able to display waveform of voltage and current able to set 2nd-51st harmonic of voltage and current, measure the waveform distortion and harmonic content, and display harmonic chart;
High resolution of voltage, current and power;
Large LCD display and simple interface for operation;
Full automatic, semi automatic and manual operation available;
Aluminum alloy material,light and strong and corrosion resistant;
Wide current measuring range which can be automatically switched;
With auto PC control software;
With barcode scanning function optional;
Meter positions can be chosen from 3 - 48;
Self-check and perfect protection function;
High stability of power source which is up to 0.01%/100s and low distortion which is no more than 0.3%;
High accuracy, 6-digit display the energy relative errors are no more than 0.05%(0. 1%)within the measuring range;
Equipped with sing phase mulfunction reference meter and progam-conrolled single phase power source which can be separately used and are convenient for testing;
Electrical parameters | |
---|---|
Accuracy | 0.02%, 0.05%, 0.1% |
Power Supply | AC 180-265V, or 3×220/380V±15%, frequency 50/60Hz. |
AC Voltage Output | |
Range | 57.7V, 100V, 220V, 380V (max 480V) |
Adjustment range | (0-120)%RG(1) |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | 0.01%/120s |
Distortion | 0.3% (Non-capacitive load) |
Output load | 1500VA |
Measuring accuracy | 0.02%RG or 0.05% RG |
AC Current Output | |
Range(I1,I2,I3) | 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 25A, 50A, 100A, 120A |
Adjustment range | (0-120)%RG |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | <0.01%/120s |
Distortion | ≤0.3% (Non-capacitive load) |
Output load | 1500VA |
Accuracy | 0.02%RG or 0.05% RG |
Power Output | |
Active power output stability | <0.01%RG/120s |
Reactive power output stability | <0.02%RG/120s |
Active power measuring accuracy | 0.02%RG or 0.05% RG |
Reactive power measuring accuracy | 0.1%RG |
Phase Output | |
Output adjustment range | 0°-359.999° |
Output adjustment fineness | 10, 1, 0.1, 0.01 as optional. |
Resolution | 0.01° |
Accuracy | 0.02° or 0.05° |
Power Factor | |
Adjustment range | -1 ~ 0 ~ 1 |
Resolution | 0.0001 |
Measurement accuracy | 0.0005 |
Frequency Output | |
Adjustment range | 40Hz-70Hz |
Output adjustment fineness | 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. |
Resolution | 0.001Hz |
Accuracy | 0.002Hz |
Voltage /Current/Harmonic Setting | |
Harmonic number | 2-51times |
Harmonic content | 0-40% |
Harmonic phase | 0-359.99 |
Harmonic setting accuracy | (10%±0.1%)RD(2) |
Power Energy Measurement Error | |
Active power energy | 0.05%RG or 0.02% RG |
Reactive power energy | 0.1%RG |
Power Pulse Output | |
Power pulse type | active pulse, reactive pulse |
Active power pulse output | 5V, 10mA |
Pulse output frequency | Max 50kHz |
Power Pulse Input | |
Pulse constant set range | (1--599999999)/kwh |
Energy pulse type | support active and reactive pulse, the highest frequency power pulse input is 200KHz. |
Meter Position | |
Position | 3, 6, 12, 20, 24, 40, 48pcs meter |
Standard | |
Standard | IEC 62053-21,22, 23; IEC 60736; ANSI C12.20-2002; JJG 597-2005; JJG596-2012; JJG 1085-2013; JJF 68-2019; DL/T 826-2002; DL/T 1478-2015; DL/T 448-2016; EN 50470-1, EN 50470-2, EN-50470-3; IEC 61010; |
Safety | |
Isolation protection | IEC 61010-1:2001 |
Measurement Category | 300 V CAT III, 600 V CAT II |
Degree of protection | IP20 |
Declaration of conformity | CE & CNAS certified |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | Cabinet size: 800 * 600 * 1850mm (L * W * H). Bench size: 2*2400 * 760 * 1846mm (L * W * H). |
Weight (kg) | About 200 |
Environmental conditions | |
Ambient temperature | 0°C to +40°C |
Relative humidity | 35%-85% |
(1) RG means range, the same as below; (2) RD means the setted harmonic content, harmonic can be a single output, also multiple output. |