Multifunction Digital Meter Calibration Electrical Equipment

After-sales Service: 24 Hours Service
Warranty: 3 Years Warranty
Application: Mechanical Instrument, Electromagnetic Instrument
Power: Electricity
Certification: FDA, CE, IAF, CCC
Voltage Output: 1000V
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF333
Current Output
100A
Thermocouple (TC)
No
Resistance-Temperature Detector (RTD)
No
LCD Display
With LCD Display
Customized
Customized
Accuracy Class 
0.02%, 0.05%
Frequency Measurement Range
45-65Hz
Weight (Kg)
10
Harmonics
2-31
PC Software
Optional
Transport Package
Standard Export Wooden Box
Specification
440*360*160
Trademark
GFUVE
Origin
Beijing, China
Production Capacity
1000pieces/Month

Product Description

Multifunction digital meter calibration electrical equipment

GF333 can be used as a calibration device standard meter, also as a testing calibrator in measurement test center of grid corporation, power company and measurement department in power plant, national levels of measurement mechanism, quality inspection departments, research institutes, tertiary institutions, industrial and mining enterprises, electric energy meter and electrical instrument production enterprises etc.
 
Multifunction Digital Meter Calibration Electrical Equipment
Multifunction Digital Meter Calibration Electrical Equipment
Multifunction Digital Meter Calibration Electrical Equipment
Features
Measure the AC voltage, current, active power, reactive power, frequency, phase angle and power factor etc;
Measure the AC voltage, current 2~31 harmonic content and waveform distortion degree;
Measure active power energy error, reactive power energy error, the maximum output pulse frequency is to 2 MHZ;
Measure calibration device of voltage, current, power stability;
Measure calibration device the standard deviation of estimate;
Measure the voltage of the calibration device three-phase symmetric degrees, the current of three three-phase symmetric degree;
Measure calibration device of the magnetic induction;
Measure DC voltage and DC current;
Transducer measurement;
With RS232 interface, it can be controlled by PC operation;
Core part uses the 32 bit DSP and16 bit low power and high speed DAC consists of high accuracy AC collector.
Using 6.5 inch TFT color LCD screen, character display clear chart. Have the advantages of wide measuring range, high precision, stable and reliable operation, simple operation etc.

Parameters
Electrical parameters
Accuracy class  0.02%, 0.05%
Power supply AC 220 V±10% or 110 V±10%, 50/60Hz
Power consumption <30VA
Warming-up time <30min
Voltage measurement
U1, U2,U3 6.25V, 12.5V, 25V, 50V, 100V, 200V, 400V, 800V (switch automatically), max 1000V
Range (0-120%)RG
Resolution 0.01%RG
Accuracy 0.02%RD or 0.05%RD
Current measurement
I1, I2, I3 0.25, 0.5, 1, 2.5, 5, 10, 25, 50, 100A(switch automatically)
Range (0-120%)RG
Resolution 0.01%RG
Accuracy 0.02%RD or 0.05%RD
Power measurement
Active accuracy 0.02%RD or 0.05%RD
Reactive accuracy 0.05%RD or 0.1%RD
Apparent accuracy 0.02%RD or 0.05%RD
Energy measurement
Active accuracy 0.02%RD or 0.05%RD
Reactive accuracy 0.05%RD or 0.1%RD
Phase measurement
Range 0.00°-359.99°
Resolution 0.001°
Accuracy 0.02° (voltage ≥50V and current ≥250mA)
Frequency measurement
Range 45-65Hz
Resolution 0. 001Hz
Accuracy 0.002Hz
Power Factor measurement
Range -1.0 ~ 0 ~ +1.0
Resolution 0.0001
Accuracy 0.0005
Electric energy pulse output 
Pulse constant range 1-2880000000
Output frequency of max. pulse 600 kHz
Load capacity >2mA
Default pulse output frequency 10kHz-600kHz
Energy pulse Input
Input range of pulse constant 600-700000
Setting range of test pulse 1-999999999
Max. pulse receiving frequency 2MHz
Pulse input level 5V
Voltage/current harmonics measurement
Times 2-31
Error 0.05%
Distortion degree error 0.05%
Transducer measurement
DC voltage range ±1, ±5, ±10, ±20 V
Accuracy 0.01%
DC current range ±1, ±2.5, ±5, ±10, ±20mA
Accuracy 0.01%
Ripple error 1%
DC measurements (option)
DC voltage 50V, 100V, 200V, 400V, 800V (switch automatically), max 1000V
Range (0 -120%) RG
Resolution 0.01% RG
Accuracy 0.02% RD
DC current 0.1A, 0.3A, 1A, 3A, 10A, 30 A(switch automatically)
Range (0-120%) RG
Resolution 0.01% RG
Accuracy 0.02% RD
Mechanical parameters
Dimensions (W×H×D) (mm) 440×360×160
Weight (kg) 10
Environmental conditions
Operating temperature 10°C to 30°C
Relative humidity ≤85%