| Customization: | Available |
|---|---|
| Warranty: | Three Years |
| Type: | Universal Testing Machine |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Voltage | |
| Test voltage output (Phase-Neutral) | 0V - 264V |
| Power of the voltage output | Max. 30VA, 15VA |
| Resolution | 0.01% |
| Accuracy | 0.1%, 0.2% |
| Stability | 0.02%/120s, 0.05%/120s |
| Distortion factor | < 0.3% for linear resistance load |
| Current | |
| Test current output | 1mA - 120A, 1mA - 60A |
| Power of the current output | Max. 100VA, 30VA |
| Resolution | 0.01% |
| Accuracy | 0.1%, 0.2% |
| Stability | 0.02%/120s |
| Distortion factor | < 0.3% for linear resistance load |
| Phase angle | |
| Range | 0 -- 360° |
| Resolution | 0.1° |
| Accuracy | 0.2° |
| Frequency | |
| Range | 45Hz - 65Hz |
| Resolution | 0.005Hz |
| Pulse output | |
| High frequency output(CH) | 1.666× 10 5 Hz |
| Low frequency output(CL) | 5× 10 -5 × CH |
| Pulse input | |
| Input channel | 3 |
| Input frequency | Max. 20Hz |
| Other | |
| Voltage Supply | 220V± 10% 50/60Hz± 2Hz |
| Ambient temperature | -10° C-- +40° C |
| Relative humidity | 35% -- 85% |
| Dimensions (W × D × H) (mm) | 445× 440× 180, 410× 220× 150 |
| Weight (kg) | 18, 9.5 |