Hv Epoxy Resin Cast Zero Sequence Current Transformer for Protection Device
Product Details
| Customization: | Available |
|---|---|
| Voltage Type: | AC Voltage |
| Measuring Principle: | Electromagnetic Type |
Diamond Member Since 2013
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Address
Bldg. 2-1111, Joy Mansion, No. 99 Chaoyang North Road, Chaoyang District, Beijing, China
International Commercial Terms(Incoterms)
FOB, CIF, FCA, EXW
Terms of Payment
LC, T/T, PayPal, Western Union
Find Similar Products
Basic Info.
- Model NO.
- LZCK2500-10
- Output Signal Type
- Digital Type
- Material
- New Magnetic
- Accuracy Grade
- 0.1G
- Certification
- CE
- Name
- Zero Sequence Current Transformer
- Usage
- Protection Current Transformer
- Application
- Protection Device of Current Measurement
- Color
- Red and Black
- Ratio
- 100-2000A/5A or 1A
- Load
- 2.5va-20va
- Diameter
- 120mm, 140mm, 160mm
- Class
- 5p10, 10p10
- Weight
- 7kg-10kg
- Transport Package
- Standard Carton Packaging, Each Box 10 Sets
- Specification
- CE, PCI PTS, EMV, MasterCard PayPass, Visa paywave
- Trademark
- PAX
- Origin
- Beijing, China
- HS Code
- 8504231100
- Production Capacity
- 2000sets/Month
Product Description
Detailed Product Description
Theory
Current transformers typically consist of a silicon steel ring core wound with many turns of copper wire as shown in the illustration to the right. The conductor carrying the primary current is passed through the ring. The CT's primary, therefore, consists of a single 'turn'. The primary 'winding' may be a permanent part of the current transformer, i.e. a heavy copper bar to carry current through the core. Window-type current transformers (aka zero sequence current transformers, or ZSCT) are also common, which can have circuit cables run through the middle of an opening in the core to provide a single-turn primary winding. To assist accuracy, the primary conductor should be centered in the aperture.
Applications
LZCK2500-10 zero sequence current transformer is suitable for current measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system. It is widely used in compact fully insulated ring network switchgears such as ABB-Safe Ring/Safe Plus...and cable distribution boxes. The current transformer can be directly installed at the inlet andoutlet cables.The slice is imported silicon material. Thesemicircular ring core and secondary windings
zero sequence current transformer is mainly measurement current for Protection device

Features
New magnetic material is taken to be the core of the current transformer, which has high magnetic permeability, low saturation magnetization and good stability. Therefore, the measuring accuracy is higher and the instrument security factor is lower. Since the high quality silicon processed by advanced technology is taken to be the core of the protection windings, which assured the accuracy limit factor is higher.
The semicircular ring core and secondary windings are vacuum poured by high quality epoxide resin in the fire retardant plastic casing, which has the characteristic of moisture proof, stable performance and dispensing with maintenance.Small size, light weight, small footprint, fixed in the ring network switchgear cable.The cable can cross the current transformer through its internal poles quickly and uniformly.
The Cast Resin Straight-Through Current Transformer can be divided several kinds according to the various current ratio, accuracy and rated loads. The specific parameters are showed in the corresponding to each model parameter tables.
PARAMETERS
| Name: | Zero Sequence Current Transformer | Material: | New Magnetic |
| Usage: | Protection Current Transformer | Application: | Protection Device Of Current Measurement |
| Color: | Red And Black | Ratio: | 100-2000A/5A Or 1A |
| Load: | 2.5VA-20VA | Diameter: | 120mm, 140mm, 160mm |
| Class: | 5P10, 10P10 | Weight: | 7KG-10KG |
Theory
Current transformers typically consist of a silicon steel ring core wound with many turns of copper wire as shown in the illustration to the right. The conductor carrying the primary current is passed through the ring. The CT's primary, therefore, consists of a single 'turn'. The primary 'winding' may be a permanent part of the current transformer, i.e. a heavy copper bar to carry current through the core. Window-type current transformers (aka zero sequence current transformers, or ZSCT) are also common, which can have circuit cables run through the middle of an opening in the core to provide a single-turn primary winding. To assist accuracy, the primary conductor should be centered in the aperture.
Applications
LZCK2500-10 zero sequence current transformer is suitable for current measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system. It is widely used in compact fully insulated ring network switchgears such as ABB-Safe Ring/Safe Plus...and cable distribution boxes. The current transformer can be directly installed at the inlet andoutlet cables.The slice is imported silicon material. Thesemicircular ring core and secondary windings
zero sequence current transformer is mainly measurement current for Protection device

Features
New magnetic material is taken to be the core of the current transformer, which has high magnetic permeability, low saturation magnetization and good stability. Therefore, the measuring accuracy is higher and the instrument security factor is lower. Since the high quality silicon processed by advanced technology is taken to be the core of the protection windings, which assured the accuracy limit factor is higher.
The semicircular ring core and secondary windings are vacuum poured by high quality epoxide resin in the fire retardant plastic casing, which has the characteristic of moisture proof, stable performance and dispensing with maintenance.Small size, light weight, small footprint, fixed in the ring network switchgear cable.The cable can cross the current transformer through its internal poles quickly and uniformly.
The Cast Resin Straight-Through Current Transformer can be divided several kinds according to the various current ratio, accuracy and rated loads. The specific parameters are showed in the corresponding to each model parameter tables.
PARAMETERS
| Technical parameters | |
| Standards | IEC60044-1; IEC 61869-2; NTC 2205; ANSI C57.13; GB1208-2006 |
| Rated primary current | 100-2000A |
| Rated load | ≤20VA |
| Rated frequency | 50Hz or 60Hz |
| Rated secondary current | 5A or 1A |
| Rated short-time thermal current | 40kA, 1S |
| Rated continuous thermal current | 120%I1n |
| Secondary winding power-frequency voltage | 3kV, 1min |
| Instrument security factor | FS≤10 |
| Mechanical parameters | |
| Dimensions (W×D×H) (mm) | φ120xφ185x100 |
| Weight (kg) | 7 |
| Operating conditions | |
| Operating temperature | -35°C to +55°C |
| Daily average temp | <+40°C |
| Storage temperature | -40°C to +70°C |
| Altitude | <3500 meters |
| Condition | No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current. |
SELECTION GUIDE
| Type | LZCK2500-10 | LZCK2500-10 | ||||
| Purpose | Measuring current transformer | Protection current transformer | ||||
| Ratio | Accuracy class and rated load(VA) | Accuracy class and rated load(VA) | ||||
| I1/I2 | 0.5 | 1 | 3 | 10P15 | 10P10 | 10P5 |
| 300/5 | 5 | 5 | 5 | 2.5 | 5 | 7.5 |
| 400/5 | 5 | 5 | 5 | 2.5 | 5 | 7.5 |
| 500/5 | 5 | 7.5 | 7.5 | 5 | 7.5 | 10 |
| 600/5 | 5 | 7.5 | 7.5 | 5 | 7.5 | 10 |
| 800/5 | 10 | 10 | 10 | 5 | 10 | 15 |
| 1000/5 | 10 | 15 | 15 | 5 | 10 | 15 |
| 1200/5 | 15 | 20 | 20 | 10 | 15 | 20 |
| 1500/5 | 15 | 20 | 20 | 10 | 15 | 20 |
SELECTION GUIDE
| Model | Primary rated current | Rated load | Aperture (mm) | Description (mm) | Weight (kg) | Material | Water-proof |
| LZCK-55 | 100-1500A | ≤10VA | φ55 | 180×138×52 | 2 | ABS+Resin | IP65 |
| LMCK185-10 | 300-3000A | ≤25VA | φ185 | 350×283×55 | 4.5 | ABS+Resin | IP65 |
| LZCK310-10 | 300-600A | ≤10VA | φ50 | φ50 x φ110 x 32 | 1 | Resin | silicon case (option) |
| LZCK322-10 | 30-600A | ≤10VA | φ50 | φ50 x φ110 x 52 | 1.6 | Resin | silicon case (option) |
| LZCK350-10 | 20-600A | ≤25VA | φ50 | φ50 x φ110 x 105 | 3.1 | Resin | silicon case (option) |
| LZCK720-10 | 20-1000A | ≤25VA | φ60 | φ80 x φ110 x 50 | 2.1 | Resin | silicon case (option) |
| LZCK2500-10 | 500-1500A | ≤20VA | φ120 | φ120 x φ185 x 100 | 7 | Resin | silicon case (option) |
| LZCG530-10 | 30-600A | ≤20VA | φ45 | φ45 x φ120 x 65 | 2.1 | Resin | silicon case (option) |
| LZCG930-10 | 100-1500A | ≤25VA | φ60 | φ60 x φ155 x 60 | 3.6 | Resin | silicon case (option) |
| LZCT722-10 | 20-600A | ≤10VA | φ82 | φ82 x φ130 x 55 | 2.3 | Resin | silicon case (option) |