Gfuve Class 0.02 High Precision Portable CT Analyzer

  • Audited Supplier
  • 14 yrs

Contact Supplier

Product Images of Gfuve Class 0.02 High Precision Portable CT Analyzer

Gfuve Class 0.02 High Precision Portable CT Analyzer
Gfuve Class 0.02 High Precision Portable CT Analyzer pictures & photos
Gfuve Class 0.02 High Precision Portable CT Analyzer
Gfuve Class 0.02 High Precision Portable CT Analyzer pictures & photos
Gfuve Class 0.02 High Precision Portable CT Analyzer
Gfuve Class 0.02 High Precision Portable CT Analyzer pictures & photos
Gfuve Class 0.02 High Precision Portable CT Analyzer
Gfuve Class 0.02 High Precision Portable CT Analyzer pictures & photos
Gfuve Class 0.02 High Precision Portable CT Analyzer
Gfuve Class 0.02 High Precision Portable CT Analyzer pictures & photos
Gfuve Class 0.02 High Precision Portable CT Analyzer
Gfuve Class 0.02 High Precision Portable CT Analyzer pictures & photos
Gfuve Class 0.02 High Precision Portable CT Analyzer
  • Gfuve Class 0.02 High Precision Portable CT Analyzer
  • Gfuve Class 0.02 High Precision Portable CT Analyzer
    Gfuve Class 0.02 High Precision Portable CT Analyzer
  • Gfuve Class 0.02 High Precision Portable CT Analyzer
    Gfuve Class 0.02 High Precision Portable CT Analyzer
  • Gfuve Class 0.02 High Precision Portable CT Analyzer
    Gfuve Class 0.02 High Precision Portable CT Analyzer
  • Gfuve Class 0.02 High Precision Portable CT Analyzer
    Gfuve Class 0.02 High Precision Portable CT Analyzer
  • Gfuve Class 0.02 High Precision Portable CT Analyzer
    Gfuve Class 0.02 High Precision Portable CT Analyzer
  • Gfuve Class 0.02 High Precision Portable CT Analyzer
    Gfuve Class 0.02 High Precision Portable CT Analyzer

Find Similar Products

Product Description

PORTABLE PORTABLE PRECISION CURRENT TRANSFORMER TESTING CT PT ANALYZER

Gfuve Class 0.02 High Precision Portable CT Analyzer

GF1061 portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.
Gfuve Class 0.02 High Precision Portable CT AnalyzerGfuve Class 0.02 High Precision Portable CT Analyzer

MAIN FUNCTIONS

I. Current Transformer (CT) II. Voltage Transformer (PT)
1. Magnetization curve 1. Excitation characteristic test
2. Transformation ratio test 2. Transformation ratio test
3. Polarity 3. Polarity 
4. 5% and 10% error curve 4.  Ratio error, phase error
5. Accuracy limiting factor (ALF) 5. Degauss
6. Degauss 6. Calculation of knee point value
7. Ratio error, phase error 7. Actual secondary load test (burden test)
8. Automatic calculation of excitation knee
point value
8. Resistance test
9. Actual secondary load test (burden test)
10. Resistance test
11. Secondary time constant (Ts)
12. Remanence coefficient (Kr)
13. Transient dimensioning factor (Ktd)
14. Peak instantaneous error (Er)
15. Magnetizing inductance (LU)
16. Instruments security factor(FS)
17. Composite error

PARAMETERS

Electrical parameters
Accuracy 0.05%
Power supply AC 220V±10% or AC 120V±10%, 50/60Hz or Battery
Output voltage 0-100Vrms
Output current 0-5Arms (20A peak-value)
Output power 0-400 VA (1500 VApeak)
Automatic frequency variation range 0.1-60Hz
Equivalent excitation voltage ≤5000V
Accuracy ≤0.5%
Secondary winding DC resistance measurement Range 0.1-1000Ω
Accuracy ≤0.05%
Secondary actual load measurement Range 5VA-1000VA
Accuracy ≤0.5%±0.1VA
CT/PT phase error measurement Accuracy ±1min (typical) / 3 min (guaranteed)
Resolution 0.1min
CT ratio error measurement Range 1-50000
Accuracy ≤0.05%
PT ratio error measurement Range 1-10000
Accuracy ≤0.05%
Standards
Reference standards GB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Mechanical parameters
Overall dimension (L x W x H) (mm) 280 x 250 x 160
Weight (kg)   ≤4
Environmental conditions
Relative humidity    Relative humidity 5%-95% not condensing
Operating temperature -10°C to +50°C
Storage temperature -20°C to +70°C
Altitude ≤1000m

http://guangfuhui.en.made-in-china.com
Gfuve Class 0.02 High Precision Portable CT Analyzer
 

About the Supplier

Watch Video
Watch Video
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.

About Our Factory & Business Background

Address
Bldg. 2-1111, Joy Mansion, No. 99 Chaoyang North Road, Chaoyang District, Beijing, China
Terms of Payment
LC, T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, CIF, FCA, EXW
Average Lead Time
Peak Season Lead Time, one month, Off Season Lead Time, within 15 workdays
Nearest Port
TIANJING

Our Production Capability & Technical Expertise

Main Products
Current Transformer, Energy Meter Calibration, Power Quality Analyzer, Test Equipment, CT PT Analyzer, Relay Test Equipment, Split Core Current Transformer, Current Probe, Voltage Transformer, Power Meter

Our Industry Experience & Global Business Record

Export Year
2010-08-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Product Groups

Product Catalogs