Dielectric Insulation Current Transformer Test Equipment

Product Details
Customization: Available
After-sales Service: Yes
Warranty: Yes
Gold Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
>2000 square meters
  • Dielectric Insulation Current Transformer Test Equipment
  • Dielectric Insulation Current Transformer Test Equipment
  • Dielectric Insulation Current Transformer Test Equipment
  • Dielectric Insulation Current Transformer Test Equipment
  • Dielectric Insulation Current Transformer Test Equipment
  • Dielectric Insulation Current Transformer Test Equipment
Find Similar Products

Basic Info.

Model NO.
GF106
Power Supply
AC 220V±10% or AC 110V±10%, 50/60Hz
Excitation Output Voltage
0-220vrms
Excitation Output Current
0-5arms (20A Peak-Value)
Automatic Frequency Variation Range
0.1-60Hz
Equivalent Excitation Voltage
≤5000V
Weight (Kg)
≤10
Relative Humidity
90rh%
Operating Temperature
-10°c to +40°c
Altitude
≤2000m
Transport Package
Standard Package
Specification
410 x 250 x 300
Trademark
GFUVE
Origin
China
Production Capacity
100000 Pieces/Mes

Product Description

GF106 CT/PT TESTER is mainly used for field testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.
 
Electrical parameters
Accuracy 0.05%, 0.1%
Power supply AC 220V±10% or AC 110V±10%, 50/60Hz
Excitation output voltage 0-220Vrms
Excitation output current 0-5Arms (20A peak-value)
Automatic frequency variation range 0.1-60Hz
Equivalent excitation voltage ≤5000V
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary winding DC resistance measurement Range 0.1-300Ω
Accuracy ≤0.5% (0.2%RD+0.3%RG)
Secondary actual load measurement Range 5VA-1000VA
Accuracy ≤0.5% (0.2%RD+0.3%RG)±0.1VA
CT/PT phase error measurement Accuracy ±4min
Resolution 0.01min
CT ratio error measurement Range 1-30000
Accuracy ≤0.5%
PT ratio error measurement Range 1-10000
Accuracy ≤0.5%
Standards
Reference standards GB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2-2012
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2/3/4/6
Mechanical parameters
Overall dimension (L x W x H) (mm) 410 x 250 x 300 
Weight (kg)   ≤10 
Environmental conditions
Relative humidity    90RH%
Operating temperature -10°C to +40°C
Altitude ≤2000m

FUNCTION 
I. Current Transformer (CT) II. Voltage Transformer (PT)
1.  Magnetization curve 1.  Excitation characteristic test
2.  Transformation ratio test 2.  Transformation ratio test
3.  Polarity 3.  Polarity
4.  5% and 10% error curve 4.  Ratio error, phases
5.  Current Injecting 5.  Degauss
6.  Degauss 6.  Calculation of knee point value
7.  Ratio error, phases 7.  Actual secondary load (burden), test (burden)
8.  Automatic calculation of excitation knee point value 8.  Resistance test
9.  Actual secondary load test (burden) (load test)
10.  Resistance test
11.  Secondary winding time constant (Ts)
12.  Remanence coefficient (Kr)
13.  Transient dimensioning factor (Ktd)
14.  Peak instantaneous error (Er)
15.  Magnetizing inductance (LU)
Dielectric Insulation Current Transformer Test Equipment

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More