• Fu-32 Flex-Core Low Voltage Split Core Current Transformer with 200/5A
  • Fu-32 Flex-Core Low Voltage Split Core Current Transformer with 200/5A
  • Fu-32 Flex-Core Low Voltage Split Core Current Transformer with 200/5A
  • Fu-32 Flex-Core Low Voltage Split Core Current Transformer with 200/5A
  • Fu-32 Flex-Core Low Voltage Split Core Current Transformer with 200/5A
  • Fu-32 Flex-Core Low Voltage Split Core Current Transformer with 200/5A

Fu-32 Flex-Core Low Voltage Split Core Current Transformer with 200/5A

Application: Power, Electronic, Instrument
Phase: Single
Core: Core-type Transformer
Cooling Method: Dry-type Transformer
Winding Type: Two-winding Transformer
Certification: ISO9001-2000, ISO9001, CCC
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
FU-32
Usage
Single-phase Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Brand
Gfuve
Characteristic and Application
Avaliable for Cable That Under 500A Online Measure
Dimensions
83mmx129mmx28mm
Output Mode
2.5m Cable Lead Output
Class
0.5, 0.2, 1
Ratio
400/5A, 300/5A, 200/5A, 500/5A
Burden
2.5va, 5va
Types
Low Voltage Split Core Current Transformer
Weight
700g
Diameter
32mm
Standards
IEC/En60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.1
Transport Package
Standard Export Carton
Specification
CE, ISO9001: 2008, IEC
Trademark
GFUVE
Origin
Beijing, China
HS Code
8504311000
Production Capacity
10000PCS/Month

Product Description

FU-32 Flex-Core Low Voltage Split core Current Transformer with 200/5A
Fu-32 Flex-Core Low Voltage Split Core Current Transformer with 200/5A
Characteristic and application: Avaliable for cable that under 500A online measurement
Diameter of clamping wire: φ 32MM
Overall dimensions: 83MMx129MMx28MM
Load capacity: ≤ 4Ω (MA output), 0.1Ω (1A output), 2.5VA(5A output)
Installation: Suspension, use the screws to tighten the opening
Output mode: Lead output

Technical parameter
Technical parameters  
Standards IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13
Ratio 400: 5 or 200:5 , customized
Nominal input current(Primary current) 100A/150A/200A/300A/400A/500A/600A
Overload withstand 1.2 times rated current continuously
Accuracy 0.2%, 0.5 %, 1%
System Voltage 720V(0.72kV)
Output signal 1A  or 5A
333mV AC or 100mV-2V optional
Burden 2.5VA
Frequency range 40 Hz....500 Hz
Dielectric strength 3KV 50Hz/60Hz  at 1 minute
Output Standard 2.5 meter cable
Max. jaw opening 32 mm
Mechanical parameters  
Dimensions (W×D×H) (mm) 110mm x 130mm x 41 mm
Weight (g) 700
Operating conditions  
Operating temperature -25 to +55°C
Relative Humidity 0-85% non-condensing
Altitude <3500 meters
Condition No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.

Send your message to this supplier