Application: Mechanical Instrument, Electromagnetic Instrument
Power: Electricity
Voltage Output: 0-300V
Current Output: 0~180A
LCD Display: With LCD Display
Customized: Customized
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
Test-630
AC Current Output
0~180A
AC Voltage Output
0~260V
Power Voltage
AC220V±10%, 50Hz±10%
Temperature
0~45
Class
0.1
LCD
8.4 Inch
System
Win XP
Types
Instrument Relay Tester
Transport Package
Standard Export Carton
Specification
CE, ISO9001: 2008, IEC
Trademark
GFUVE
Origin
Beijing China
Production Capacity
100sets/Month

Product Description

Features of Circuit Breaker Measurement Analysis Instrument relay tester,Test-630 Relay protection test equipment,CE,ISO9001:2008,IEC approved,english version display,two years quality warranty.
Circuit Breaker Measurement Analysis Instrument Relay Tester
Circuit Breaker Measurement Analysis Instrument Relay Tester
Circuit Breaker Measurement Analysis Instrument Relay Tester
Integration in the host crystal 8.4 inches true color, light weight and easy to carry;
Built-in high-speed high-performance industrial computer, embedded operating system, running a stable and reliable; Also be connected PC testing;
Panel embedded user-friendly buttons can also be an external keyboard, mouse;
High-precision DAC to 12 Road, simultaneous output to ensure that waveform fitting of high precision, good linearity;
Matching electromagnetic compatibility components, can improve on-site anti-electromagnetic interference, protection devices can be connected electromagnetic compatibility tests;

Analog output of the front panel, switch the amount of terminal design in the upper cover, all the wiring does not affect the operation of the panels and test parameters of the surveillance;
Designed to the latest thermal structure, and to ensure the best ventilation. Automatically determine the over-current, over voltage, overload, short circuit, the temperature is too high, data anomalies and misuse warning prompt;
Using voltage, current amplifier AC / DC sharing, output stage uses a unique ultra-linear amplifier technology, high precision, good reliability; Six-phase AC output voltage and six-phase AC current;
12 analog ports, and the other optional auxiliary DC source output (220V/110V);
Interface: RJ45 (Ethernet interface), USB interface (software upgrades, reporting transmission), industrial serial interface (GPS or other serial device use).

Functions
Host real-time operating system, fast response, when faced with an emergency situation, to better protection of instruments and equipment under test. Safe and reliable, not easy to be a computer virus violated;
The newly designed software interface style, the host machine operation is fully consistent with the background and easy;
Extensive testing capabilities: The state sequence determined in the trial, IT features analog oscillation, the entire group of tests, differential protection, harmonic superposition, low cycle load shedding, same equipment, measuring instruments, GPS synchronized debugging, fault playback, and custom test (special tests), etc., to satisfy various types of user testing microprocessor-based protection relay needs. Can easily complete the Siemens, AREVA and other foreign manufacturers of protective device test.
The test report can be easily derived from the USB port to print.
AC current output Phase current output (effective value)                                              6×0~30A or 3×0~60A
Maximum output power                                               520VA/phase
Maximum parallel current output (effective value)                          0~180A
Long-term allowable working value of phase current (effective value)     >10A
Allowable working time of maximum current                    >11s
Accuracy                                                   <±0.2%
AC voltage output Phase voltage output (effective value)                            6×0~130V
Line voltage output (effective value)                                  0~260V
Maximum output power                        70VA/phase
Accuracy                                       <±0.2%
DC voltage output Output range                                                   0~300V or 6×0~±130V
Maximum output power                                                      130VA
Accuracy                                                                     <±0.2%
DC current output Output range                                                    -10~10A or 6×0~±10A
Maximum output power                                                    150VA
Accuracy                                                                <±0.2%
Binary input Idle contact                                                      1~20mA, 24V (DC)
Electric potential contact                                          0~250V (DC)
Binary output Idle contact                                                    250V/0.5A (DC)
Rated output Frequency error           <±0.01HzHz
Phase error                         <±0. 2°
Waveform distortion               <±0.3% (fundamental wave)
Time error                             <40µs
Output frequency               0~1050Hz
Superposed harmonic wave        0~21times
Power voltage Allowable range              AC220V±10%, 50Hz±10%
Ambient temperature Use range                          0~45
Storage range                     -25~70
Time measurement Test range                 0.1ms~999999.999s
Exterior appearance of cabinet Imported electromagnetic compatible cabinet, which is made of high-grade all aluminum alloy extruded section and has fine appearance, is selected.
Dimension of cabinet: length×width×height 360mm×195mm ×365mm
Weight of cabinet Weight of host machine          16.6kg
Load-bearing output Selectable between light load or heavy load output
(When any phase current output surpasses 15A, it is suggested to press key F3 before test of each functional module so as to switch to heavy load output mode)