FU2200A-0.5s RS485 Smart Three Phase Digital stage Panel Power Energy Meter
Introduction
FU9000 series of three AC voltage, current multi-function meter is a traditional digital meters of the replacement Product. This product has the function of traditional products, also has programmable functions, DC4~20mA analog output, RS-485 communication interface port and the switching signal output functions. This product has high accuracy, excellent EMC, and pleasing in appearance and so on.
FU2200B 0-800V digital power meter with PC software is a three-phase multifunction power and energy meter manufactured by GFUVE. It provides excellent value for monitoring power and energy management systems. It may be used as data gathering devices for intelligent power distribution or plant automation systems. All monitored data is available via a standard digital RS485 communication port, which is based on the Modbus RTU protocol.
Technical Parameter
Network Analyzer Electrical Equipment Most Demanded Products Single Phase Energy Meter Energy Monitor Online Toc Analyzer
Total Station
1ProgrammablePT, CT Ratio, Address, Baud rate and other parameters.
2Accuracy0.5 Class
3Display Figures4 bits
4Rated inputCurrent: 1A, 5A
Voltage: 100V, 220V, 380V
5Over RangeCurrent: 1.2 times continual, 10 times/10s;
Voltage: 2 times continual
6Frequency50± 5Hz or 60± 10Hz (Optional)
7Power SupplyAC220V ± 20% or DC100~300V (Customization)
8Power consumption<3VA
9Insulation strength2KV/Min. 2mA
10Insulation resistance≥ 100MΩ
11MTBF≥ 50000Hrs
12Working EnvironmentTemperature: -25~55
Humidity: ≤ 98% RH, Without condensation
13Real-time outputDC4~20mA, Load capacity: ≤ 400Ω
14Data outputRS-485 Port (ModBus-RTU Protocol)
15Switching inputRemote signal input (self power supply): AC or DC 220V
16Switching output (Self-control)Normally open contact output: AC 250V / DC 30V, 5A
Parameters |
Accuracy |
Resolution |
Measuring range |
Show on the display |
Voltage |
0.20% |
0.01V |
0-400V |
0.5-500kV |
Current |
0.20% |
0.01mA |
0-6.5A |
5mA-50000A |
Active power |
0.50% |
0.2W |
0-2400W/phase |
-9999MW to +9999MW |
Reactive power |
2% |
0.2var |
0-2400var/phase |
-9999Mvar to +9999Mvar |
Apparent power |
0.50% |
0.2VA |
0-2400VA/phase |
0-9999MVA |
Active demand |
0.50% |
0.2W |
0-2400W/phase |
-9999MW to +9999MW |
Reactive demand |
2% |
0.2var |
0-2400var/phase |
-9999Mvar to +9999Mvar |
Apparent demand |
0.50% |
0.2VA |
0-2400VA/phase |
0 to 9999MVA |
Power factor |
0.005 |
0.0001 |
-2 |
-2 |
Frequency |
0.01Hz |
0.01Hz |
45.000-65.000Hz |
45.000-65.000Hz |
Active energy |
0.5%,0.2% (Option) |
0.001kWh |
0-999999.999kWh |
0-99999999.9kWh |
Reactive energy |
2% |
0.001kvarh |
0-999999.999kvarh |
0-99999999.9kvarh |
Apparent energy |
0.50% |
0.001VAh |
0-999999.999kVAh |
0-99999999.9kVAh |
Phase angle |
0.1° |
0.01° |
0-359.99° |
0-359.99° |
Unbalance |
2% |
0.01% |
0-300.00% |
0-300.00% |
PT ratio |
|
1 |
|
1-10000 |
CT ratio |
|
1 |
|
1-10000 |
Address code |
|
1 |
|
1-253 |
Photo