Customization: | Available |
---|---|
Warranty: | 3 Years |
Safety Regulations: | En61010 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Auto check;
Low power design;
With luminous beep;
Wireless mode check ;
70V~550kV phase check;
3.5 inch color LCD display ;
Wide detection voltage range;
Standard IEC6148-A2:2004; IEC61243-1;
PARAMETERS
Electrical parameters | |
---|---|
Function | Frequency measurement, phase measurement, phase sequence display, voltage measurement and voltage inspection |
Power supply | Phasor checker: DC7.5V, Alkaline Dry Battery AA X 5 Detector: 9V cell batteries(6F22) |
Checking phasor mode | Contact type check phasor: the bare conductor below 35KV or the conductor with insulating sheath below 550kV can contact the conductor core phase and non-contact type check phasor. When the bare line voltage exceeds 35kV, non-contact test must be adopted, and the probe gradually approaches the check phasor of the conductor. |
Transmission distance | Wireless transmission, straight-line transmission distance is about 30 m |
Phase discrimination | Same phase shift:-30°~30°; different phase shift:90°~150° & 210°~270° |
Checker phasor voltage | 70V - 550kV |
Phase range | 0.0° - 360.0°; accuracy:≤±12°; Resolution: 0.1° |
Frequency range | 45.0Hz - 65.0Hz;accuracy:≤±2Hz; Resolution: 0.1Hz |
Voltage range | 70V - 110kV; accuracy:±15%±5dgt; Resolution: 100V |
Voltage accuracy | High voltage overhead line ±15%±5dgt(Other applications:±25%±5dgt) |
Emission frequency | 433MHz, 315MHz |
LCD | 3.5 inch color LCD, 72mm×55mm |
Phase indication | Phasor diagram and digital display at the same time |
Work instructions | During checker phasor, the detector has sound and light indication function, red double flashing light indication and "beep beep beep |
Data storage | 100 Groups |
Consumption | Detector: Max 70mA; Phasor checker: Max 150mA |
Length of insulating rod | Maximum diameter Φ 38mm; Reduced length: 800mm; The extension is 3015mm |
Insulation strength | Phasor checker & Detector: 3.7kVrms; Both ends of insulating rod after stretching: AC 220kV/rms |
Suitable for Safety Regulations | EN61010-1:2001, EN61010-031:2002, IEC61481-A2:2004; IEC61243-1 ; GB13398-92; GB311.1-311.6-8; 3DL408-91; General technical conditions for 1kV ~ 35kV portable phasor checker for live working DL/ T971-2005 |
Mechanical parameters | |
Dimension (L×W×H) (mm) | Phasor checker: 187×119×48mm Detector: 146×100mm |
Weight (kg) | Detector: 250g (with Metal hook & battery)*2, Phasor checker: 450g(with battery) |
Environmental conditions | |
Operating Temperature | -15°C to +55°C |
Storage Temperature | -20°C to +65°C |
Relative humidity | 0%-85% RH |