Current Sensor
The model Q50A current probe is designed for fast and easy measure the current in industrial and power environment, it has wide range of current measurement from 1mA to 1000A, High precision 0.1%, easy operation for measurement instruments. Meet EN61010-2-032 standard. The Q50A AC current clamp are designed to extend the current measuring capabilities of DMMs or BNC, power instruments, oscilloscopes, hand-held scopes, recorders or loggers, clamp type grounding resistance tester, double clamp phase angle meter, energy meter calibrator and other diverse instruments.
Characteristic and application: Suitable for 1000 A cable online measurement...
But holding wire diameter: Φ 50mm
Dimension: 101mm× 219mm× 26mm
(View outline drawing)
With load capacity: Ma output≤ 4Ω , 1A output 0.1Ω , 5A output 2.5VA
Installation: Clamp type
Output mode: Lead output
Electrical parameters |
Ratio |
1000: 1 or 2000:1 (customized) |
Accuracy class |
0.1%, 0.2%, 0.5% |
Primary current |
0 - 1000A AC |
Secondary current |
0-1A AC, 0 - 5A AC (customized) |
Max. Cont. Input current |
1200A |
Load capacity |
≤20Ω, standard 4Ω |
Over voltage category |
CAT III 600V |
Output signal |
500mA,1A,5A AC at nominal input current |
Frequency range |
40Hz-20kHz |
Dielectric strength |
3KV 50Hz/60Hz at 1 minute |
Temperature range |
-20°C to +55°C |
Output |
2.5 meter cable with D01 connector |
Max. voltage not insulated conductors |
720 V |
Standard |
EN 61010-1, EN 61010-2-032, EN 61010-2-031
IEC60044-1, & IEC61869-2, 600V CAT III |
Installation |
Clamp type |
Output mode |
Lead output (2.5m) |
Connector |
BNC, 4mm banana, signal cable(2 cores),customized |
Accuracy (1000A Range) |
0-10A |
≤0.5% |
10-100 |
≤0.2% |
10-1000A |
≤0.1% |
Phase Shift(1000A Range) |
0-10A |
≤0.5° |
10-100 |
≤0.2° |
10-1000A |
≤0.1° |
Mechanical parameters |
Dimensions (L x W x H) (mm) |
102.9 x 219.6 x 28 |
Weight (g) |
550 |
Holding wire diameter (mm) |
φ50 |
Max. jaw opening (mm) |
50 |
Jaw color |
Blue or grey |
Material |
PC+ABS+Polycarbonate, UL94 V0 |
Primary current |
Secondary current |
Precision |
10A |
2.5mA |
Class 0.1%, 0.2%, 0.5% |
10A |
5mA |
Class 0.1%, 0.2%, 0.5% |
20A |
5mA |
Class 0.1%, 0.2%, 0.5% |
100A |
20mA |
Class 0.1%, 0.2%, 0.5% |
100A |
40mA |
Class 0.1%, 0.2%, 0.5% |
100A |
50mA |
Class 0.1%, 0.2%, 0.5% |
100A |
100mA |
Class 0.1%, 0.2%, 0.5% |
200A |
80mA |
Class 0.1%, 0.2%, 0.5% |
200A |
100mA |
Class 0.1%, 0.2%, 0.5% |
200A |
200mA |
Class 0.1%, 0.2%, 0.5% |
300A |
120mA |
Class 0.1%, 0.2%, 0.5% |
300A |
150mA |
Class 0.1%, 0.2%, 0.5% |
300A |
200mA |
Class 0.1%, 0.2%, 0.5% |
300A |
300mA |
Class 0.1%, 0.2%, 0.5% |
500A |
100mA |
Class 0.1%, 0.2%, 0.5% |
500A |
200mA |
Class 0.1%, 0.2%, 0.5% |
|
500A |
250mA |
Class 0.1%, 0.2%, 0.5% |
|
500A |
500mA |
Class 0.1%, 0.2%, 0.5% |
|
Primary current |
Secondary current |
Precision |
|
600A |
120mA |
Class 0.1%, 0.2%, 0.5% |
|
600A |
200mA |
Class 0.1%, 0.2%, 0.5% |
|
600A |
300mA |
Class 0.1%, 0.2%, 0.5% |
|
600A |
400mA |
Class 0.1%, 0.2%, 0.5% |
|
600A |
500mA |
Class 0.1%, 0.2%, 0.5% |
|
600A |
600mA |
Class 0.1%, 0.2%, 0.5% |
|
700A |
200mA |
Class 0.1%, 0.2%, 0.5% |
|
700A |
350mA |
Class 0.1%, 0.2%, 0.5% |
|
700A |
700mA |
Class 0.1%, 0.2%, 0.5% |
|
800A |
160mA |
Class 0.1%, 0.2%, 0.5% |
|
800A |
200mA |
Class 0.1%, 0.2%, 0.5% |
|
800A |
250mA |
Class 0.1%, 0.2%, 0.5% |
|
800A |
320mA |
Class 0.1%, 0.2%, 0.5% |
|
800A |
400mA |
Class 0.1%, 0.2%, 0.5% |
|
800A |
500mA |
Class 0.1%, 0.2%, 0.5% |
|
800A |
800mA |
Class 0.1%, 0.2%, 0.5% |
|
500A ~ 1000A |
1A |
Class 0.2%, 0.5% |
|
600A ~ 1000A |
1A |
Class 0.1%, 0.2%, 0.5% |
|
200A |
5A |
Class 1% |
|
300A ~ 500A |
5A |
Class 0.5% |
|
500A ~ 1000A |
5A |
Class 0.2%, 0.5% |
|
Grounding resistance tester supporting |
Need to match special instrument |
Class 0.1%, 0.5% |