• High Precision Portable CT PT Analyzer 0.02% / 0.05% Ratio Error with Printer
  • High Precision Portable CT PT Analyzer 0.02% / 0.05% Ratio Error with Printer
  • High Precision Portable CT PT Analyzer 0.02% / 0.05% Ratio Error with Printer
  • High Precision Portable CT PT Analyzer 0.02% / 0.05% Ratio Error with Printer
  • High Precision Portable CT PT Analyzer 0.02% / 0.05% Ratio Error with Printer
  • High Precision Portable CT PT Analyzer 0.02% / 0.05% Ratio Error with Printer

High Precision Portable CT PT Analyzer 0.02% / 0.05% Ratio Error with Printer

After-sales Service: Yes
Warranty: 3 Years
Application: CT PT Tester
Power: Electricity
Certification: CE, PCI Pts
Voltage Output: 0-120V
Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
GF106T
Current Output
0-5A
Thermocouple (TC)
R
LCD Display
With LCD Display
Customized
Customized
Name
CT PT Analyzer
Theory
DC Variable-Frequency Methods
Usage
Measurement CT and Protection C
Phase Error
1min or 3min
Ratio Error
0.02% or 0.05%
CT Raito
1-50000
PT Ratio
1-10000
Weight
4kg
Transport Package
Standard Carton Packaging
Specification
7inch TFT Touch Color LCD
Trademark
PAX
Origin
Beijing, China
HS Code
8480410090
Production Capacity
1000sets/Month

Product Description

Detailed Product Description High Precision Portable CT PT Analyzer 0.02% / 0.05% Ratio Error with Printer

 
Name: CT PT Analyzer Application: Current Transformer And Potential Transformer Test
Theory: DC Variable-frequency Methods LCD: 7inch TFT Touch Color LCD
Phase Error: 1min Or 3min Ratio Error: 0.02% Or 0.05%
CT Raito: 1-50000 PT Ratio: 1-10000
Usage: Measurement CT And Protection CT Weight 4KG

GF1061 portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.
The CT Analyzer automatically determines all relevant current transformer values and compares the results with the selected standard. The device evaluates the current transformer as per the IEC or IEEE standard within seconds with the push of a button. its can test current transformer and potential transformer ratio error and phase error, Magnetization curve etc
It facilitates fast and economical on-site testing and calibration of metering and protection current transformers. Manufacturers of current transformers, high voltage transformers and switchgear also use the CT Analyzer for tests during development and production.

Application

1. Measurement type current transformer
2. Protection type current transformer
3. GIS type current transformer
4. Bushing type current transformer
5. Zero sequence current transformer
6. Voltage transformer

MAIN FUNCTIONS

I. Current Transformer (CT) II. Voltage Transformer (PT)
1. Magnetization curve 1. Excitation characteristic test
2. Transformation ratio test 2. Transformation ratio test
3. Polarity 3. Polarity
4. 5% and 10% error curve 4. Ratio error, phase error
5. Accuracy limiting factor (ALF) 5. Degauss
6. Degauss 6. Calculation of knee point value
7. Ratio error, phase error 7. Actual secondary load test (burden test)
8. Automatic calculation of excitation knee
point value
8. Resistance test
9. Actual secondary load test (burden test)
10. Resistance test
11. Secondary time constant (Ts)
12. Remanence coefficient (Kr)
13. Transient dimensioning factor (Ktd)
14. Peak instantaneous error (Er)
15. Magnetizing inductance (LU)
16. Instruments security factor(FS)
17. Composite error

 

 

PARAMETERS

 
 
Electrical parameters
Accuracy 0.05%, 0.02%
Power supply AC 220V±10% or AC 120V±10%, 50/60Hz or Battery
Output voltage 0-100Vrms
Output current 0-5Arms (20A peak-value)
Output power 0-400 VA (1500 VApeak)
Automatic frequency variation range 0.1-60Hz
Equivalent excitation voltage ≤5000V
Accuracy ≤0.5%
Secondary winding DC resistance measurement Range 0.1-1000Ω
Accuracy ≤0.05%
Secondary actual load measurement Range 5VA-1000VA
Accuracy ≤0.5%±0.1VA
CT/PT phase error measurement Accuracy ±1min (typical) / 3 min (guaranteed)
Resolution 0.1min
CT ratio error measurement Range 1-50000
Accuracy ≤0.05%
PT ratio error measurement Range 1-10000
Accuracy ≤0.05%
Standards
Reference standards GB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13
Safety standards GB 4793.1-2007
EMC EMC standard 89/336/EEC
FCC Subpart B of Part 15 Class A
IEC 1000-4-2 /3 /4 /6
Mechanical parameters
Overall dimension (L x W x H) (mm) 280 x 250 x 160
Weight (kg) ≤4
Environmental conditions
Relative humidity Relative humidity 5%-95% not condensing
Operating temperature -10°C to +50°C
Storage temperature -20°C to +70°C
Altitude ≤1000m
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now