T-3730 Ground Pile Resistance Clamp Test Device

Product Details
Customization: Available
Current Range: 0.00mA-60.0A
Resistance Accuracy: ±1%±0.01Ω
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
>2000 square meters
  • T-3730 Ground Pile Resistance Clamp Test Device
  • T-3730 Ground Pile Resistance Clamp Test Device
  • T-3730 Ground Pile Resistance Clamp Test Device
  • T-3730 Ground Pile Resistance Clamp Test Device
  • T-3730 Ground Pile Resistance Clamp Test Device
  • T-3730 Ground Pile Resistance Clamp Test Device
Find Similar Products

Basic Info.

Model NO.
T-3730
Power Supply
DC 3.7 V Lithium Battery
Resistance Resolution
0.001Ω
Resistance Range
0.01-2000Ω; 0.01-1800Ω; 0.01-1500
Current Accuracy
±2.5%±1mA
Voltage Range
0.00V-600.0V
Specification
273mm× 106mm× 53mm
Origin
China

Product Description

T-3730

GROUND PILE RESISTANCE CLAMP TEST DEVICE

T-3730 Ground Pile Resistance Clamp Test Device

The T-3730 ground pile resistance clamp tester uses 2.4-inch color screen design, with clamp resistance, three or four wire resistance, AC voltage, current measurement functions, and also has data storage, data access, alarm, automatic shutdown and other functions. The ground-pile clamp ground resistance tester is controlled by a microprocessor and can accurately detect ground resistance. It uses fast filtering technology to minimize interference. At the same time with data storage and data upload functions.DESCRIPTIONThe T-3730 ground pile resistance clamp is beautiful and high-grade, wide range, high resolution, convenient operation, easy to carry, accurate, reliable, stable performance, strong anti-interference ability.It also has a shock-proof, dust-proof, and moisture-proof structure. It is a commonly used and indispensable instrument for telecommunications, electric power, meteorology, computer rooms, oil fields, electronic mechanical installation and maintenance, and industrial enterprises that use electricity as industrial power or energy. This model T-3730 ground pile resistance clamp is suitable for measuring grounding resistance of various telecommunications, electricity, meteorology, computer rooms, oil fields, power distribution lines, transmission lines of iron towers, gas stations, factory grounding grids, lightning rods, etc.

FUNCTION & FEATURES

500 group storage;

Testing AC voltage;

User friendly operation;

Quick self-test function;

Testing loop resistance;

Testing leakage current;

Real time clock function;

Bluetooth communication;

USB Data upload function;

Testing ground resistance;

2.4inch touch color display;

Built-in rechargeable battery;

Ground voltage range 0-600V AC;

This new design for clamp long life;

Clamp resistance range 0.01-2000Ω;

4/3/2 pile method range 0.00Ω-30kΩ;

Soil resistivity range 0.00Ω-9999kΩm;

Using fast filtering technology, strong anti-interference ability;

APPLICATION

Universities;

Power plant;

Oil gas company;

Research institutes;

Electrical laboratory;

Electrical testing center;

Telecommunication company;

Railway electrical department;

Electrical equipment manufacturers;

Electricity power bureau & power company;

Power engineering commissioning company;

Electrical Department of industrial and mining enterprises;

PARAMETERS

Electrical parameters
Model T-3730A 0-1500Ω, 0-40A, 0-3000Ω(3w/4w method);
T-3730B 0-1800Ω, 0-50A, 0-30kΩ(3w/4w method), 0.00Ω-9999kΩm;
T-3730C 0-2000Ω, 0-60A, 0-30kΩ(3w/4w method), 0.00Ω-9999kΩm;
Power Supply DC 3.7 V lithium battery
Resistance Range 0.01-2000Ω; 0.01-1800Ω; 0.01-1500Ω;
Resistance Resolution 0.001Ω
Resistance Accuracy ±1%±0.01Ω
Current Range 0.00mA-60.0A
Current Resolution 0.001mA
Current Accuracy ±2.5%±1mA
Voltage Range 0.00V-600.0V
Voltage Resolution 0.01V
Data memory 500 Sets
LCD Screen 2.4 inch color touch LCD screen display, Screen L×W: 46mm×29mm
Clamp Opening 68mm
Protection Level Dual Insulation
Structural Feature Clamp CT
Shifting Automatic shifting
External magnetic field <40A/m
External electrical field <1V/m
Single measurement time 0.5 second
Resistance measurement frequency >1KHz
Measured current frequency 50/60Hz Automatic measurement
Power Consumption Max 75mA either in booting up or normally working, Continuously working for 20 hours
Safety Standard IEC61010-1(CAT 300V, CAT IV 600V, Pollution Degree 2);
IEC61010-032; IEC/EN61557-5, 13, 16; IEC61326
Communication port USB, Bluetooth;
PC software Yes
Mechanical parameters
Dimensions (L×W×T) (mm) 273mm×106mm×53mm
Weight (kg) 1 (With batteries)
Environmental conditions
Operating Temperature -10°C to +50°C
Storage Temperature -40°C to 70°C
Relative humidity ≤90%RH