Electrical Single Phase Current Transducer
Product Details
| Customization: | Available |
|---|---|
| Type: | Electromagnetic |
| Output Signal Type: | Digital Output |
Diamond Member Since 2013
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Address
Bldg. 2-1111, Joy Mansion, No. 99 Chaoyang North Road, Chaoyang District, Beijing, China
International Commercial Terms(Incoterms)
FOB, CIF, FCA, EXW
Terms of Payment
LC, T/T, PayPal, Western Union
Find Similar Products
Basic Info.
- Model NO.
- FUD-U -I
- Production Process
- Integration
- Material
- Stainless Steel
- Accuracy Grade
- 0.2G
- Application
- Switching Power Supply
- Certification
- CE
- Customized
- Customized
- Accuracy
- 0.2%, 0.5%
- Insulation Voltage
- AC 2kv/Min.1mA (Between Input ~ Output / Power)
- Surge Voltage
- 5kv
- Input Range
- AC 0~10A, AC 0~500V(Optional), 50/60Hz
- Installation
- 35mm DIN Sliding-Way or M4 Screws
- Dimension
- 55mm×75mm×120mm
- Output
- 4-20mA, 0-5V
- Transport Package
- Standard Export Carton
- Specification
- CE, ISO9001: 2008, IEC
- Trademark
- GFUVE
- Origin
- Beijing China
- Production Capacity
- 5000PCS/Month
Product Description
Single Phase AC Current / Voltage Transducer
Function & Feature
Transforms the measured AC current/voltage to the DC current/voltage output according to the linear scale
Excellent temperature characteristic and good working stability
Configuration compactness and briefness
Technical Index
Function & Feature
Transforms the measured AC current/voltage to the DC current/voltage output according to the linear scale
Excellent temperature characteristic and good working stability
Configuration compactness and briefness
| FUD-Type-Input-Power Supply-Output | |
| Type | I: Single Phase AC Current Transducer U: Single Phase AC Voltage Transducer Ir: Single Phase AC Real RMS Current Transducer Ur: Single Phase AC Real RMS Voltage Transducer |
| AC Input | A1: 0~1A, A2: 0~5A, A3: 0~10A. V0: 0~70V, V1: 0~120V, V2: 0~250V, V3: 0~300V, V4: 0~450V, V5: 0~500V. |
| Power Supply | P1: AC110V±10%, P2: AC220V±15%, P3: AC110V~330V. |
| DC Output | O1: 0~5V, O2: 1~5V, O3: 0~20mA, O4: 4~20mA, O5: RS485. |
| Example 1: FUD-I-A2-P2-O4 | |
| FUD Series Single Phase AC Current Transducer | Input: AC0~5A |
| Power Supply: AC220V±15% | |
| Output: DC4~20mA | |
| Example 2: FUD-Ur-V3-P2-O4 | |
| Details: FUD Series Single Phase AC Real RMS Voltage Transducer | Input: AC 0~300V |
| Power Supply: AC220V±15% | |
| Output: DC4~20mA | |
| Please check the Type, Input range, Output range and Power supply at your order. | |
Technical Index
| Standard | GB/T 13850-1998, IEC688:1992 |
| Accuracy | 0.2%, 0.5% |
| Consumption | ≤3VA |
| Accutacy drift | Annual Variation < 0.2% |
| Insulation Voltage | AC 2kV/min.1mA (Between Input ~ Output / Power) |
| Insulation Resistance | ≥20MΩ (DC500V) |
| Surge voltage | 5KV (Peak Value), 1.2/50μs |
| Response Time | ≤350ms |
| Input Range | AC 0~10A ,AC 0~500V(Optional), 50/60Hz |
| Absorbed Power | <0.5VA/450V, <0.2VA/100V, <0.1VA/5A |
| Overload | Current: 2 times continuous,30 times /1s .Voltage: 2 times continuous |
| Load Resistance | Current output: RL≤550Ω Voltage output: RL≥2kΩ |
| Working environment | Temperature: -10~50 RH: 20~90%, Without condensation |
| Storage conditions | Temperature: -40~70 RH: 20~95%, Without condensation |
| Installation | 35mm DIN Sliding-way or M4 screws |
| Dimension | 55mm×75mm×120mm |