  • Customizable Input/Output: DC input and output ranges are fully customizable to meet specific application needs.
  • High Precision Accuracy: Accuracy class reaches 0.2% with annual variation drift less than 0.2%.
  • Wide Application Scope: Suitable for oil systems, power plants, industrial fields, and rail electrical systems.
  • Robust Insulation Protection: Features 2kV insulation voltage and 5KV surge voltage protection for safety.
  • Flexible Installation Options: Supports 35mm DIN sliding-way or M4 screws for easy mounting.
  • CE Certified Quality: Product holds CE certification ensuring compliance with European standards.

Product Images of DC Voltage Transducer

DC Voltage Transducer pictures & photos
DC Voltage Transducer
DC Voltage Transducer pictures & photos
DC Voltage Transducer
DC Voltage Transducer pictures & photos
DC Voltage Transducer
DC Voltage Transducer pictures & photos
DC Voltage Transducer
DC Voltage Transducer pictures & photos
DC Voltage Transducer
DC Voltage Transducer pictures & photos
DC Voltage Transducer
  • DC Voltage Transducer
    DC Voltage Transducer
  • DC Voltage Transducer
    DC Voltage Transducer
  • DC Voltage Transducer
    DC Voltage Transducer
  • DC Voltage Transducer
    DC Voltage Transducer
  • DC Voltage Transducer
    DC Voltage Transducer
  • DC Voltage Transducer
    DC Voltage Transducer

Find Similar Products

Product Description

DC Voltage TransducerDC Voltage TransducerDC Voltage TransducerDC Voltage Transducer

APPLICATION

Oil system;

Power plant;

Industrial filed;

Coal auto system;

Rail electrical system;

Electricity power company;

Metallurgy electrical system;

FEATURES

DC voltage transducer;

DC current transducer;

Accuracy class can reach 0.2%;

DC input range can be customized;

DC output range can be customized;

Technical Index

Technical Index
Standard QB/441600 17 079-2001
Accuracy 0.2%, 0.5%
Consumption ≤3VA
Accuracy drift Annual variation <0.2%
Insulation voltage AC 2kV/min.1mA (Between input- output/power)
Insulation resistance ≥20MΩ (DC500V)
Surge voltage 5KV (peak value), 1.2/50μs
Response time ≤350ms
Input range AC 0-10A ,AC 0-500V(Option)
Absorbed power ≤0.1VA
Overload Current: 2 times continuous, 20 times/1s;
Load resistance Current output: RL ≤550Ω
Voltage output: RL ≥2kΩ
Working environment Temperature: -10 to +50°C
RH: 20-90%, without condensation
Storage conditions Temperature: -40 to +70°C
RH: 20-95%, without condensation
Installation 35mm DIN sliding-way or M4 screws
Dimension 55mm x 75mm x 120mm

Model Description

FUD-Type-Input-Power Supply-Output
Type DI: DC current transducer
DV: DC voltage transducer
DC input A1: 0-75mA, A2: 0-100mA, A3: 0-±75mV, A4: 0-±100mV, A5: 0-20mA, A6: 4-20mA, A7: 0-5A, A8: 0-15A, V0: 0-5V, V1: 0-30V, V2: 0-60V, V3: 0-300V, V4: 0-400V, V5: 0-450V, Vn: User define.
Power supply P1: AC 85-265V or DC 100-330V, P2: DC 20-60V.
DC output O1: 0-5V, O2: 1-5V, O3: 0-20mA, O4: 4-20mA, O5: 1-3-5V, O6: 4-12-20mA.
Example 1: FUD-DI-A2-P1-O4
FUD series DC current transducer Input: DC 0-100mA
Power supply: AC220V±15%
Output: DC4-20mA
Example 2: FUD-DU-V3-P1-O4
Details: FUD series DC voltage transducer Input: DC 0-300V
Power supply: AC220V±15%
Output: DC4-20mA
*Please check the type, input range, output range and power supply when your order the product.

About the Supplier

Watch Video
Watch Video
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.
Beijing GFUVE Electronics Co., Ltd.

About Our Factory & Business Background

Address
Bldg. 2-1111, Joy Mansion, No. 99 Chaoyang North Road, Chaoyang District, Beijing, China
Terms of Payment
LC, T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, CIF, FCA, EXW
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
TIANJING

Our Production Capability & Technical Expertise

Main Products
Current Transformer, Energy Meter Calibration, Power Quality Analyzer, Test Equipment, CT PT Analyzer, Relay Test Equipment, Split Core Current Transformer, Current Probe, Voltage Transformer, Power Meter

Our Industry Experience & Global Business Record

Export Year
2010-08-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the accuracy grade of this transducer?
The accuracy grade can reach 0.2% or 0.5%, with an annual variation drift of less than 0.2%.
Can the input and output ranges be customized?
Yes, both the DC input range and DC output range can be customized according to your requirements.
What are the available installation methods?
The device supports installation via 35mm DIN sliding-way or M4 screws.
What is the response time of the transducer?
The response time is less than or equal to 350ms.
What certifications does the product have?
The product is CE certified.
What are the typical application scenarios?
It is widely used in oil systems, power plants, industrial fields, coal auto systems, rail electrical systems, and metallurgy electrical systems.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

People who viewed this also viewed

Product Groups

Product Catalogs